Liquid chromatography-tandem mass spectrometry method for determination of phencynonate in rat blood and urine

被引:10
|
作者
Kou, YY
Xu, YX
Xue, M [1 ]
Ruan, JX
Zhang, ZQ
Liu, KL
机构
[1] Capital Univ Med Sci, Dept Pharmacol, Sch Chem Biol & Pharmaceut Sci, Beijing 100069, Peoples R China
[2] Beijing Inst Pharmacol & Toxicol, Beijing 100850, Peoples R China
基金
中国国家自然科学基金;
关键词
phencynonate; anticholinergic drug; liquid chromatography-mass spectrometry; rat blood; quantification;
D O I
10.1016/j.jchromb.2005.09.028
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and specific high-performance liquid chromatographic assay with electrospray ionization mass spectrometry detection (LC-ESI-MS) has been developed and validated for the identification and quantification of the novel anticholinergic drug phencynonate in rat blood and urine. The sample pretreatment involves basification and iterative liquid-liquid extraction with ethyl ether-dichloromethane (2:1, v/v) solution, followed by LC separation and positive electrospray ionization mass spectrometry detection. The chromatography was on BetaBasic-18 column (150 mm x 2.1 mm i.d., 3 mu m). The mobile phase was composed of methanol-water (85:15, v/v), containing 0.5 parts per thousand, formic acid, which was pumped at a flow-rate of 0.2 ml/min. Thiencynonate was selected as the internal standard (IS). Simultaneous MS detection of phencynonate and IS was performed at m/z 358.4 (phencynonate), m/z 364 (thiencynonate), and the selected reaction ion monitoring (SRM) of the two compounds was at 156. Phencynonate eluted at approximately 5.25 min, thiencynonate eluted at approximately 5.10 min and no endogenous materials interfered with their measurement. Linearity was obtained over the concentration range of 1-100 ng/ml in rat blood and 1-500 ng/ml in rat urine. The lower limit of quantification (LLOQ) was reproducible at I ng/ml in both of rat blood and urine. The precision measured was obtained from 2.92 to 9.76% in rat blood and 4.17 to 9.76% in rat urine. Extraction recoveries were in the range of 69.57-79.49% in blood and 56.85-64.86% in urine. This method was successfully applied to the identification and quantification of phencynonate in pharmacokinetic studies. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:75 / 79
页数:5
相关论文
共 50 条
  • [1] Liquid chromatography-tandem mass spectrometry method for the determination of vanillylmandelic acid in urine
    Magera, MJ
    Thompson, AL
    Matern, D
    Rinaldo, P
    [J]. CLINICAL CHEMISTRY, 2003, 49 (05) : 825 - 826
  • [2] Liquid chromatography-tandem electrospray mass spectrometry method for determination of serial chiral novel anticholinergic compounds of phencynonate in rat plasma
    Li, Jinglai
    Zhang, Zhenqing
    Ruan, Jinxiu
    Wang, Sujun
    Liu, Keliang
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 855 (02): : 180 - 185
  • [3] Liquid chromatography-tandem mass spectrometry method for determination of thiencynonate in rat plasma
    Xu, yanxia
    Kou, yuying
    Ruan, jinxiu
    Zhang, zhenqing
    Kiu, keliang
    Xue, ming
    [J]. ACTA PHARMACOLOGICA SINICA, 2006, 27 : 212 - 212
  • [4] Sensitive Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Olanzapine in Human Urine
    Urdigere, Anil Kumar Rangachar
    Besagarahally, Bhasakra Laxmaiah
    Basavaiah, Kanakapura
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2012, 37 (05) : 1381 - 1387
  • [5] Liquid chromatography-tandem mass spectrometry determination of oxalate in spot urine
    Elgstoen, Katja B. P.
    Woldseth, Berit
    Hoie, Kari
    Morkrid, Lars
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2010, 70 (03): : 145 - 150
  • [6] Determination of endogenous steroids in urine by liquid chromatography-tandem mass spectrometry
    Wang Mengye
    Xiang Ping
    Yan Hui
    Shen Baohua
    Shen Min
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (01) : 10 - 14
  • [7] Determination of chloramphenicol in animal urine by liquid chromatography-tandem mass spectrometry
    Rodziewicz, Lech
    Zawadzka, Iwona
    [J]. BULLETIN OF THE VETERINARY INSTITUTE IN PULAWY, 2008, 52 (03) : 431 - 434
  • [8] Determination of tanshinone IIA in rat plasma by liquid chromatography-tandem mass spectrometry method
    Bi, Hui-Chang
    Zhong, Guo-Ping
    Wei, Ying-Ying
    Deng, Ying
    Chen, Xiao
    Huang, Min
    [J]. ACTA PHARMACOLOGICA SINICA, 2006, 27 : 247 - 247
  • [9] Quantitative determination of spinosin in rat plasma by liquid chromatography-tandem mass spectrometry method
    Li, Yujuan
    Yao, Meicun
    Cheng, Shan
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (04) : 1169 - 1173
  • [10] A Rapid Method to Determine Tetrabromobisphenol A in Rat Serum and Urine by Liquid Chromatography-Tandem Mass Spectrometry
    Kang, Mi Jeong
    Kim, Ju Hyun
    Lee, Sang Kyu
    Kang, Wonku
    Kim, Hyung Sik
    Lyoo, Won Seok
    Jeong, Tae Cheon
    [J]. ARCHIVES OF PHARMACAL RESEARCH, 2010, 33 (11) : 1797 - 1803