Assessment and prediction of thoracic gas volume in pregnant women: an evaluation in relation to body composition assessment using air displacement plethysmography

被引:17
|
作者
Henriksson, Pontus [1 ]
Lof, Marie [1 ]
Forsum, Elisabet [1 ]
机构
[1] Linkoping Univ, Dept Clin & Expt Med, Fac Hlth Sci, SE-58185 Linkoping, Sweden
基金
瑞典研究理事会;
关键词
Air displacement plethysmography; Body composition; Pregnancy; Thoracic gas volume; MASS INDEX; FAT; ADULTS;
D O I
10.1017/S0007114512000906
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Assessment of body fat (BF) in pregnant women is important when investigating the relationship between maternal nutrition and offspring health. Convenient and accurate body composition methods applicable during pregnancy are therefore needed. Air displacement plethysmography, as applied in Bod Pod, represents such a method since it can assess body volume (BV) which, in combination with body weight, can be used to calculate body density and body composition. However, BV must be corrected for the thoracic gas volume (TGV) of the subject. In non-pregnant women, TGV may be predicted using equations, based on height and age. It is unknown, however, whether these equations are valid during pregnancy. Thus, we measured the TGV of women in gestational week 32 (n 27) by means of plethysmography and predicted their TGV using equations established for non-pregnant women. Body weight and BV of the women was measured using Bod Pod. Predicted TGV was significantly (P = 0.033) higher than measured TGV by 6% on average. Calculations in hypothetical women showed that this overestimation tended to be more pronounced in women with small TGV than in women with large TGV. The overestimation of TGV resulted in a small but significant (P = 0.043) overestimation of BF, equivalent to only 0.5% BF, on average. A Bland-Altman analysis showed that the limits of agreement were narrow (from -1.9 to 2.9% BF). Thus, although predicted TGV was biased and too high, the effect on BF was marginal and probably unimportant in many situations.
引用
收藏
页码:111 / 117
页数:7
相关论文
共 50 条
  • [1] Body Composition Assessment in Overweight Women: Validation of Air Displacement Plethysmography
    Wingfield, Hailee L.
    Smith-Ryan, Abbie E.
    Woessner, Mary N.
    Melvin, Malia N.
    Fultz, Sarah N.
    Graff, Rachel M.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 26 - 26
  • [2] Body composition assessment in overweight women: validation of air displacement plethysmography
    Wingfield, Hailee L.
    Smith-Ryan, Abbie E.
    Woessner, Mary N.
    Melvin, Malia N.
    Fultz, Sarah N.
    Graff, Rachel M.
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2014, 34 (01) : 72 - 76
  • [3] Selection of a Thoracic Gas Volume When Using Air Displacement Plethysmography to Assess Longitudinal Body Composition Changes
    Wilson, Patrick B.
    [J]. INTERNATIONAL JOURNAL OF SPORT NUTRITION AND EXERCISE METABOLISM, 2017, 27 (06) : 485 - 486
  • [4] Evaluation of air-displacement plethysmography for body composition assessment in preterm infants
    Roggero, Paola
    Gianni, Maria L.
    Amato, Orsola
    Piemontese, Pasqua
    Morniroli, Daniela
    Wong, William W.
    Mosca, Fabio
    [J]. PEDIATRIC RESEARCH, 2012, 72 (03) : 316 - 320
  • [5] Evaluation of air-displacement plethysmography for body composition assessment in preterm infants
    Paola Roggero
    Maria L. Giannì
    Orsola Amato
    Pasqua Piemontese
    Daniela Morniroli
    William W. Wong
    Fabio Mosca
    [J]. Pediatric Research, 2012, 72 : 316 - 320
  • [6] Body composition by air-displacement plethysmography by using predicted and measured thoracic gas volumes
    McCrory, MA
    Molé, PA
    Gomez, TD
    Dewey, KG
    Bernauer, EM
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (04) : 1475 - 1479
  • [7] ASSESSMENT OF BODY COMPOSITION OF KUWAITI INFANTS BY USING AIR DISPLACEMENT PLETHYSMOGRAPHY (PEA POD®)
    Al-Mesad, Y.
    Davidsson, L.
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2018, 187 : S341 - S341
  • [8] Body composition measurement by air displacement plethysmography in pregnancy: Comparison of predicted versus measured thoracic gas volume
    Pellonpera, Outi
    Koivuniemi, Ella
    Vahlberg, Tero
    Mokkala, Kati
    Tertti, Kristiina
    Ronnemaa, Tapani
    Laitinen, Kirsi
    [J]. NUTRITION, 2019, 60 : 227 - 229
  • [9] Reliability of Repeated Trials Protocols for Body Composition Assessment by Air Displacement Plethysmography
    Muntean, Paul
    Miclos-Balica, Monica
    Popa, Anca
    Neagu, Adrian
    Neagu, Monica
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (20)
  • [10] Statistical validation of air-displacement plethysmography for body composition assessment in children
    Ittenbach, RF
    Buison, AM
    Stallings, VA
    Zemel, BS
    [J]. ANNALS OF HUMAN BIOLOGY, 2006, 33 (02) : 187 - 201