Expanded Polytetrafluoroethylene for Chordal Replacement: Preventing Knot Failure

被引:6
|
作者
Miller, Jacob R.
Deeken, Corey R.
Ray, Shuddhadeb
Henn, Matthew C.
Lancaster, Timothy S.
Schuessler, Richard B.
Damiano, Ralph J.
Melby, Spencer J. [1 ]
机构
[1] Washington Univ, St Louis Sch Med, St Louis, MO 63110 USA
来源
ANNALS OF THORACIC SURGERY | 2015年 / 100卷 / 06期
关键词
MONOFILAMENT ABSORBABLE SUTURES; MITRAL-VALVE REPAIR; MECHANICAL PERFORMANCE; FORCE DISTRIBUTION;
D O I
10.1016/j.athoracsur.2015.07.089
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose. Expanded polytetrafluoroethylene suture is commonly used for chordal replacement in mitral valve repair, but due to material characteristics, knots can unravel. Our aim was to determine the knot security, including how many throws are necessary to prevent knot failure, with Gore-Tex (W.L. Gore and Associates, Elkton, MD) and the newly available Chord-X (On-X Life Technologies Inc, Austin, TX). Description. Knots were evaluated for maximal load based on: number of throws (6, 8, 10, and 12), tension to secure each throw (10%, 50%, and 85%) and suture type (Gore-Tex CV-5 and Chord-X 3-0). A physiologic force of 2 N was used for comparison. Evaluation. We evaluated 240 knots. For all knots, the mean load to failure was 11.1 +/- 5.8 N. Failure occurred due to unraveling in 141 knots (59%) at 7.1 +/- 4.1 N and to breaking in 99 (41%) at 16.7 +/- 2.0 N (p < 0.01). Gore-Tex failed at higher loads (12.6 +/- 6.0N vs 9.5 +/- 5.2 N, p < 0.01); however, an equivalent number, 6 Gore-Tex and 6 Chord-X, unraveled at 2 N, all with fewer than 10 throws. Conclusions. Expanded polytetrafluoroethylene has adequate strength to prevent breakage; however, a risk of knot unraveling at physiologic conditions exists when fewer than 10 throws are performed. (C) 2015 by The Society of Thoracic Surgeons
引用
收藏
页码:2325 / 2329
页数:5
相关论文
共 50 条
  • [1] Chordal Replacement With Expanded Polytetrafluoroethylene Sutures to Correct Leaflet Prolapse
    David, Tirone E.
    [J]. ANNALS OF THORACIC SURGERY, 2023, 115 (01): : 103 - 104
  • [2] Ten-year experience of chordal replacement with expanded polytetrafluoroethylene in mitral valve repair
    Kobayashi, J
    Sasako, Y
    Bando, K
    Minatoya, K
    Niwaya, K
    Kitamura, S
    [J]. CIRCULATION, 2000, 102 (19) : 30 - 34
  • [3] A 25-year study of chordal replacement with expanded polytetrafluoroethylene in mitral valve repair
    Hata, Hiroki
    Fujita, Tomoyuki
    Shimahara, Yusuke
    Sato, Shunsuke
    Ishibashi-Ueda, Hatsue
    Kobayashi, Junjiro
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 20 (04) : 463 - 468
  • [4] EARLY FAILURE OF EXPANDED POLYTETRAFLUOROETHYLENE IN FEMORAL VEIN REPLACEMENT
    FAULKNER, RT
    COWAN, GSM
    ROTHOUSE, L
    [J]. ARCHIVES OF SURGERY, 1979, 114 (08) : 939 - 943
  • [5] 7-YEAR EXPERIENCE WITH CHORDAL REPLACEMENT WITH EXPANDED POLYTETRAFLUOROETHYLENE IN FLOPPY MITRAL-VALVE
    ZUSSA, C
    POLESEL, E
    DACOL, U
    GALLONI, M
    VALFRE, C
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 108 (01): : 37 - 41
  • [6] Long-term outcomes of chordal replacement with expanded polytetrafluoroethylene sutures to repair mitral leaflet
    David, Tirone E.
    David, Carolyn M.
    Lafreniere-Roula, Myriam
    Manlhiot, Cedric
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 160 (02): : 385 - +
  • [7] Long-term results of mitral valve repair for myxomatous disease with and without chordal replacement with expanded polytetrafluoroethylene sutures
    David, TE
    Omran, A
    Armstrong, S
    Sun, Z
    Ivanov, J
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (06): : 1279 - 1285
  • [8] Long-term results of mitral valve repair for myxomatous disease with and without chordal replacement with expanded polytetrafluoroethylene sutures - Discussion
    Cohn, LH
    De Vega, N
    David
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (06): : 1285 - 1286
  • [9] ARTIFICIAL CHORDAL RECONSTRUCTION WITH EXPANDED POLYTETRAFLUOROETHYLENE SUTURES FOR MITRAL-VALVE REPLACEMENT IN A PATIENT WITH MITRAL-STENOSIS - CASE-REPORT
    OKITA, Y
    MIKI, S
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1993, 106 (06): : 1225 - 1227
  • [10] Expanded polytetrafluoroethylene as tendon replacement: An experimental study in chickens
    Giorgetti, M
    Giannessi, E
    Ricciardi, MP
    [J]. SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2001, 35 (01): : 23 - 27