Effect of Various Putty-Wash Impression Techniques on Marginal Fit of Cast Crowns

被引:15
|
作者
Nissan, Joseph [1 ]
Rosner, Ofir [1 ]
Bukhari, Mohammed Amin [1 ]
Ghelfan, Oded [1 ]
Pilo, Raphael [1 ]
机构
[1] Tel Aviv Univ, Maurice & Gabriela Goldschleger Sch Dent Med, Dept Oral Rehabil, Tel Aviv, Israel
关键词
FUSED-TO-METAL; CERAMIC CROWN; ONE-STEP; IN-VITRO; DIMENSIONAL ACCURACY; SYSTEMS; SILICONE; 2-STEP; RESTORATIONS; DESIGN;
D O I
10.11607/prd.0713
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Marginal fit is an important clinical factor that affects restoration longevity. The accuracy of three polyvinyl siloxane putty-wash impression techniques was compared by marginal fit assessment using the nondestructive method. A stainless steel master cast containing three abutments with three metal crowns matching the three preparations was used to make 45 impressions: group A = single-step technique (putty and wash impression materials used simultaneously), group B = two-step technique with a 2-mm relief (putty as a preliminary impression to create a 2-mm wash space followed by the wash stage), and group C = two-step technique with a polyethylene spacer (plastic spacer used with the putty impression followed by the wash stage). Accuracy was assessed using a toolmaker microscope to measure and compare the marginal gaps between each crown and finish line on the duplicated stone casts. Each abutment was further measured at the mesial, buccal, and distal aspects. One-way analysis of variance was used for statistical analysis. P values and Scheffe post hoc contrasts were calculated. Significance was determined at .05. One-way analysis of variance showed significant differences among the three impression techniques in all three abutments and at all three locations (P < .001). Group B yielded dies with minimal gaps compared to groups A and C. The two-step impression technique with 2-mm relief was the most accurate regarding the crucial clinical factor of marginal fit.
引用
收藏
页码:E37 / E42
页数:6
相关论文
共 50 条
  • [1] A CONTROLLED PUTTY-WASH IMPRESSION TECHNIQUE
    MARSHAK, B
    ASSIF, D
    PILO, R
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1990, 64 (06): : 635 - 636
  • [2] Accuracy of three polyvinyl siloxane putty-wash impression techniques
    Nissan, J
    Laufer, BZ
    Brosh, T
    Assif, D
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (02): : 161 - 165
  • [3] BOND STRENGTH OF PUTTY-WASH ELASTOMERIC IMPRESSION MATERIALS
    SANDRIK, JL
    VACCO, JL
    [J]. JOURNAL OF DENTAL RESEARCH, 1981, 60 : 629 - 629
  • [4] CLINICALLY ORIENTED ASSESSMENT OF THE ACCURACY OF 3 PUTTY-WASH SILICONE IMPRESSION TECHNIQUES
    TJAN, AHL
    WHANG, SB
    TJAN, AH
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1984, 108 (06): : 973 - 975
  • [5] Effect of different retraction and impression techniques on the marginal fit of crowns
    Woestmann, Bernd
    Rehmann, Peter
    Trost, Dieter
    Balkenhol, Markus
    [J]. JOURNAL OF DENTISTRY, 2008, 36 (07) : 508 - 512
  • [6] A modified one-step putty-wash impression technique
    Wu, Aaron Yu-Jen
    Donovan, Terry E.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2007, 98 (03): : 245 - 246
  • [7] EFFECT OF CONTAMINANTS ON THE ADHESION OF LIGHT-BODIED SILICONES TO PUTTY SILICONES IN PUTTY-WASH IMPRESSION TECHNIQUE
    TJAN, AHL
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1988, 59 (05): : 562 - 567
  • [8] Use of wax spacers for putty-wash impression of implant snap-on impression copings
    Monzavi, A
    Siadat, H
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (05): : 494 - 494
  • [9] A modified putty-wash vinyl polysiloxane impression technique for fixed prosthodontics
    Chaimattayompol, Nopsaran
    Park, Dongwoo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2007, 98 (06): : 483 - 485
  • [10] DEFECTS IN AUTOMIXED ADDITION SILICONE ELASTOMERS PREPARED BY PUTTY-WASH IMPRESSION TECHNIQUE
    SOH, G
    CHONG, YH
    [J]. JOURNAL OF ORAL REHABILITATION, 1991, 18 (06) : 547 - 553