Determination of putrescine, cadaverine, spermidine and spermine in different chemical matrices by high performance liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (HPLC-ESI-ITMS/MS)

被引:28
|
作者
Gonzalez Ibarra, Alan Alexander [1 ]
Wrobel, Katarzyna [1 ]
Corrales Escobosa, Alma Rosa [1 ]
Torres Elguera, Julio Cesar [1 ]
Eugenia Garay-Sevilla, Ma [2 ]
Wrobel, Kazimierz [1 ]
机构
[1] Univ Guanajuato, Dept Chem, Guanajuato 36000, Mexico
[2] Univ Guanajuato, Dept Med Sci, Guanajuato 36000, Mexico
关键词
Aliphatic polyamines; 4-fluoro-3-nitrobenzenotrifluoride (FNBT); LC-MS; Multiple reaction monitoring; Plant abiotic stress; Diabetes; Urine; SOLID-PHASE EXTRACTION; BIOGENIC-AMINES; HUMAN URINE; LEPIDIUM-SATIVUM; CADMIUM STRESS; POLYAMINES; DERIVATIZATION; SAMPLES; FOODS; DERIVATIVES;
D O I
10.1016/j.jchromb.2015.08.036
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The goal of this work was to establish a simple HPLC-ESI-ITMS/MS procedure, suitable for the determination of four common aliphatic polyamines in two different types of biological matrices. To this end, 1,6-diaminohexane was used as the internal standard (IS) and 4-fluoro-3-nitrobenzenotrifluoride (FNBT) as the derivatizing agent. Formation of fully derivatized compounds was confirmed by high resolution ESI-QTOFMS and MS/MS analysis. Reversed phase chromatographic separation was carried out by gradient elution with 0.1% (v/v) formic acid and methanol. In a positive ESI mode, the following pairs of precursor/quantifier ions were used for multiple reaction monitoring: 467.4/261.0 for PUT, 481.2/461.1 for CAD, 713.7/261.0 for SPD, 959.8/507.2 for SPM and 495.3/475.2 for IS. On-column instrumental detection limits of four polyamines were in the range 0.62-2.14 fmol (0.039-0.215 ng/ml). Versatility was demonstrated by analyzing plant extracts and human urine; prior to derivatization, all samples were cleaned-up by dichloromethane extraction. The evaluated signal suppression/enhancement was in the range 82.3-115.4% and the percentage recoveries obtained in the method of standard addition were in the range 817-114.4%. Statistically significant differences in polyamines concentrations were found in garden cress exposed to Cd(II) versus control seedlings (t-test, p < 0.05); results obtained for urine from healthy volunteers and diabetic patients at different clinical conditions suggested possible utility of free polyamines as biomarkers of progressive diabetes. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:176 / 184
页数:9
相关论文
共 50 条
  • [1] Determination of ambroxol in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI)
    Su Fenli
    Wang Feng
    Gao Wei
    Li Huande
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 853 (1-2): : 364 - 368
  • [2] Determination of carnitine and acylcarnitines in urine by high-performance liquid chromatography-electrospray ionization ion trap tandem mass spectrometry
    Vernez, L
    Hopfgartner, G
    Wenk, M
    Krähenbühl, S
    JOURNAL OF CHROMATOGRAPHY A, 2003, 984 (02) : 203 - 213
  • [3] Determination of chloramphenicol in shrimp by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS)
    Tyagi, A.
    Vernekar, P.
    Karunasagar, Iddya
    Karunasagar, Indrani
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2008, 25 (04): : 432 - 437
  • [4] Investigation of antibacterial phytochemicals in the bark and leaves of Ficus coronata by high-performance liquid chromatography-electrospray ionization-ion trap mass spectrometry (HPLC-ESI-MSn) and ESI-MSn
    Smyth, Thomas J. P.
    Ramachandran, Venkataraman
    Brooks, Peter
    Smyth, W. Franklin
    ELECTROPHORESIS, 2012, 33 (04) : 713 - 718
  • [5] Determination of fumonisin in food by high performance liquid chromatography-electrospray ionization tandem mass spectrometry
    Liu, CL
    Xu, WN
    Kofoet, A
    Liu, FM
    Pan, CP
    Xu, YJ
    Jiang, SR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (11) : 1619 - 1622
  • [6] Determination of Tinuvin 292 in Acrylic Resins by Reversed-phase High-performance Liquid Chromatography-Electrospray Ionization-Ion Trap Mass Spectrometry
    Park, Insook
    Yoon, Kyung-Hwan
    Namgoong, Hyun
    CHEMISTRY LETTERS, 2012, 41 (03) : 301 - 303
  • [7] Characterization of Related Substances in Etimicin Sulfate Sample by High Performance Liquid Chromatography-Electrospray Ionization-Ion Trap-Mass Spectrometry
    Yuan Yao-Zuo
    Zhang Mei
    Qian Wen
    Zhang Zheng-Xing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (06) : 817 - 822
  • [8] Determination of amiodarone and desethylamiodarone in human plasma by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry with an ion trap detector
    Kollroser, M
    Schober, C
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 766 (02): : 219 - 226
  • [9] Simultaneous determination of fluoxetine, citalopram, paroxetine, venlafaxine in plasma by high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI)
    He, J
    Zhou, ZL
    Li, HD
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 820 (01): : 33 - 39
  • [10] Determination of nalmefene by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry
    Fang, WB
    Andrenyak, DM
    Moody, DE
    Nuwayser, ES
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2005, 29 (03) : 169 - 174