Determination of trace aluminium by adsorptive stripping voltammetry on a preplated bismuth-film electrode in the presence of cupferron

被引:90
|
作者
Kefala, G [1 ]
Economou, A [1 ]
Sofoniou, M [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Analyt Chem Lab, GR-54124 Thessaloniki, Greece
关键词
aluminium; bismuth-film electrode; adsorptive stripping voltammetry; cupferron;
D O I
10.1016/j.talanta.2005.07.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports the use of adsorptive stripping voltammetry (AdSV) for the determination of aluminium on a rotating-disc bismuth-film electrode (BiFE). Al(III) ions in the non-deoxygenated sample were complexed with cupferron and the complex was accumulated by adsorption on the surface of the preplated BiFE. The stripping step was carried out by using a square-wave (SW) potential-time voltammetric excitation signal. The experimental variables as well as potential interferences were investigated and the figures of merit of the method were established. Using the selected conditions, the 3 sigma limit of detection for aluminium was 0.5 mu g l(-1) at a preconcentration time of 240 s and the relative standard deviation was 4.2% at the 5 mu g l(-1) level for a preconcentration time of 120 s (n = 8). The accuracy of the method was established by analysing water and metallurgical samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1013 / 1019
页数:7
相关论文
共 50 条
  • [1] Adsorptive Stripping Voltammetry for Determination of Cadmium in the presence of Cupferron on a Nafion-coated Bismuth Film Electrode
    Meepun, Nipaporn
    Siriket, Suphawuth
    Dejmanee, Saravut
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 10582 - 10591
  • [2] Adsorptive stripping voltammetry of In(III) in the presence of cupferron using an in situ plated bismuth film electrode
    Wasag, Joanna
    Grabarczyk, Malgorzata
    [J]. ANALYTICAL METHODS, 2016, 8 (17) : 3605 - 3612
  • [3] Preparation of a Preplated Bismuth Film on Pt Electrode and its Application for Determination of Trace Aluminum(III) by Adsorptive Stripping Voltammetry
    Wang, Hongmei
    Yu, Zhanglong
    Wang, Zhiliang
    Hao, Haijun
    Chen, Yongmei
    Wan, Pingyu
    [J]. ELECTROANALYSIS, 2011, 23 (05) : 1095 - 1099
  • [4] Determination of trace selenium by differential pulse adsorptive stripping voltammetry at a bismuth film electrode
    Zhang, Qing
    Li, Xiangjun
    Shi, Hui
    Hongzhou
    Yuan, Zhuobin
    [J]. ELECTROCHIMICA ACTA, 2010, 55 (16) : 4717 - 4721
  • [5] Simultaneous voltammetric determination of trace bismuth(III) and cadmium(II) in water samples by adsorptive stripping voltammetry in the presence of cupferron
    Koper, Anna
    Grabarczyk, Malgorzata
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 681 : 1 - 5
  • [6] Determination of Folic Acid at a Bismuth Film Electrode by Adsorptive Stripping Voltammetry
    Rutyna, Iwona
    [J]. ANALYTICAL LETTERS, 2015, 48 (10) : 1593 - 1603
  • [7] Adsorptive stripping voltammetric determination of trace uranium with a bismuth-film electrode based on the U(VI) → U(V) reduction step of the uranium-cupferron complex
    Kefala, G
    Economou, A
    Voulgaropoulos, A
    [J]. ELECTROANALYSIS, 2006, 18 (03) : 223 - 230
  • [8] Determination of Selenium(IV) by catalytic stripping voltammetry with an in situ plated bismuth-film electrode
    Long, Jiajie
    Nagaosa, Yukio
    [J]. ANALYTICAL SCIENCES, 2007, 23 (11) : 1343 - 1346
  • [9] Determination of trace amounts of Ga(III) by adsorptive stripping voltammetry with in situ plated bismuth film electrode
    Grabarczyk, Malgorzata
    Wasag, Joanna
    [J]. TALANTA, 2015, 144 : 1091 - 1095
  • [10] Determination of trace titanium(IV) by differential pulse catalytic adsorptive stripping voltammetry at a bismuth film electrode
    Cui, Hong
    Sun, Wenhua
    Li, Xiangjun
    Zou, Hong
    Yuan, Zhuobin
    [J]. ANALYTICAL METHODS, 2013, 5 (07) : 1784 - 1789