Accuracy of Doppler Echocardiography in the Hemodynamic Assessment of Pulmonary Hypertension

被引:756
|
作者
Fisher, Micah R. [1 ]
Forfia, Paul R. [2 ]
Chamera, Elzbieta [2 ]
Housten-Harris, Traci [1 ]
Champion, Hunter C. [2 ]
Girgis, Reda E. [1 ]
Corretti, Mary C. [2 ]
Hassoun, Paul M. [1 ]
机构
[1] Johns Hopkins Univ, Div Pulm & Crit Care Med, Baltimore, MD 21224 USA
[2] Johns Hopkins Univ, Dept Med, Div Cardiol, Baltimore, MD 21224 USA
关键词
echocardiography; pulmonary hypertension; pulmonary systolic pressure; cardiac output; accuracy; CARDIAC-OUTPUT; ARTERY PRESSURE; TRICUSPID REGURGITATION; VASCULAR-RESISTANCE; HEART-FAILURE; SURVIVAL; CATHETERIZATION;
D O I
10.1164/rccm.200811-1691OC
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Rationale. Transthoracic Doppler echocardiography is recommended for screening for the presence of pulmonary hypertension (PH): However, some recent studies have suggested that Doppler echocardiographic pulmonary artery pressure estimates may frequently be inaccurate. Objectives: Evaluate the accuracy of Doppler echocardiography for estimating pulmonary artery pressure and cardiac output. Methods: We conducted a prospective study on patients with various forms of PH who underwent comprehensive Doppler echocardiography within 1 hour of a clinically indicated right-heart catheterization to compare noninvasive hemodynamic estimates with invasively measured values. Measurements and Main Results: A total of 65 patients completed the study protocol. Using Bland-Altman analytic methods, the bias for the echocardiographic estimates of the pulmonary artery systolic pressure was -0.6 mm Hg with 95% limits of agreement ranging from +38.8 to -40.0 mm Hg. Doppler echocardiography was inaccurate (defined as being greater than +/- 10 mm Hg of the invasive measurement) in 48% of cases. Overestimation and underestimation of pulmonary artery systolic pressure by Doppler echocardiography occurred with a similar frequency (16 vs. 15 instances, respectively). The magnitude of pressure underestimation was greater than overestimation (-30 +/- 16 vs. +19 +/- 11 mm Hg; P = 0.03); underestimates by Doppler also led more often to misclassification of the severity of the PH. For cardiac output measurement, the bias was -0.1 L/min with 95% limits of agreement ranging from +2.2 to -2.4 L/min. Conclusions: Doppler echocardiography may frequently be inaccurate in estimating pulmonary artery pressure and cardiac output in patients being evaluated for PH.
引用
收藏
页码:615 / 621
页数:7
相关论文
共 50 条
  • [1] Accuracy of Doppler echocardiography in the hemodynamic evaluation of pulmonary hypertension
    Fisher, MR
    Forfia, PR
    Chamera, E
    Housten, T
    Champion, HC
    Resar, J
    Corretti, M
    Girgis, RE
    Hassoun, P
    [J]. CHEST, 2004, 126 (04) : 883S - 883S
  • [2] Accuracy of Doppler echocardiography in the hemodynamic assessment of pulmonary hypertension in patients with systemic sclerosis
    Ciurzynski, M.
    Bienias, P.
    Irzyk, K.
    Rymarczyk, Z.
    Kostrubiec, M.
    Lichodziejewska, B.
    Szewczyk, A.
    Glinska-Wielochowska, M.
    Kurzyna, M.
    Pruszczyk, P.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 : 869 - 870
  • [3] Accuracy of Doppler echocardiography in the assessment of pulmonary hypertension in liver transplant candidates
    Kim, WR
    Krowka, MJ
    Plevak, DJ
    Lee, J
    Rettke, SR
    Frantz, RP
    Wiesner, RH
    [J]. LIVER TRANSPLANTATION, 2000, 6 (04) : 453 - 458
  • [4] Accuracy of Doppler echocardiography in the hemodynamic assessment of pulmonary circulation in patients with systemic sclerosis
    Ciurzynski, Michal
    Bienias, Piotr
    Ciesielska, Katarzyna
    Chrzanowska, Anna
    Dudzik-Niewiadomska, Iwona
    Kurnicka, Katarzyna
    Domienik-Karlowicz, Justyna
    Siwicka, Maria
    Sobieraj, Piotr
    Kalinska-Bienias, Agnieszka
    Kurzyna, Marcin
    Pruszczyk, Piotr
    [J]. ADVANCES IN MEDICAL SCIENCES, 2019, 64 (02): : 309 - 314
  • [5] How accurate is trans-thoracic Doppler echocardiography for the hemodynamic assessment of pulmonary hypertension ?
    Artaud-Macari, E.
    Muir, J. -F.
    Cuvelier, A.
    Molano, L. -C.
    Viacroze, C.
    Mouton-Schleiffer, D.
    Lamia, B.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181
  • [6] Accuracy of Doppler echocardiography in the assessment of pulmonary arterial hypertension in patients with congenital heart disease
    Wang, B.
    Feng, Y.
    Jia, L-Q
    Wu, X-L
    Li, D-D
    Zhou, H-X
    Yang, J.
    Liang, B-M
    Wang, L.
    Cui, K-J
    Huang, H.
    Yi, Q.
    [J]. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2013, 17 (07) : 923 - 928
  • [7] Accuracy of Doppler Echocardiography in the Assessment of Pulmonary Arterial Hypertension In Patients With Congenital Heart Disease
    Wang, Bo
    Zhou, Haixia
    Yang, Jing
    Liang, Binmiao
    Feng, Yulin
    [J]. CHEST, 2016, 149 (04) : 509A - 509A
  • [8] QUANTITATIVE ASSESSMENT OF PULMONARY-HYPERTENSION BY DOPPLER ECHOCARDIOGRAPHY
    ALI, SA
    SERGAKOVA, LM
    [J]. KARDIOLOGIYA, 1988, 28 (07) : 112 - 115
  • [9] Assessment of pulmonary vascular resistance by Doppler echocardiography in patients with pulmonary arterial hypertension
    Selimovic, Nedim
    Rundqvist, Bengt
    Bergh, Claes-Hakan
    Andersson, Bert
    Petersson, Sofia
    Johansson, Lena
    Bech-Hanssen, Odd
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2007, 26 (09): : 927 - 934
  • [10] Non-invasive assessment of pulmonary hypertension:: Doppler-echocardiography
    Sciomer, Susanna
    Magri, Damiano
    Badagliacca, Roberto
    [J]. PULMONARY PHARMACOLOGY & THERAPEUTICS, 2007, 20 (02) : 135 - 140