Error bounds in diffusion tensor estimation using multiple-coil acquisition systems

被引:6
|
作者
Beltrachini, Leandro [1 ]
von Ellenrieder, Nicolas [1 ]
Horacio Muravchik, Carlos [1 ]
机构
[1] Univ Nacl La Plata, LEICI, Fac Ingn, La Plata, Buenos Aires, Argentina
关键词
Cramer-Rao bound; Noncentral chi distribution; Measurement noise; DT-MRI; FRACTIONAL ANISOTROPY; PHASED-ARRAY; HUMAN BRAIN; FRAMEWORK; RECONSTRUCTION; TRACTOGRAPHY; UNCERTAINTY; COMBINATION; STRATEGIES;
D O I
10.1016/j.mri.2013.04.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We extend the diffusion tensor (DT) signal model for multiple-coil acquisition systems. Considering the sum-of-squares reconstruction method, we compute the Cramer-Rao bound (CRB) assuming the widely accepted noncentral chi distribution. Within this framework, we assess the effect of noise in DT estimation and other measures derived from it, as a function of the number of acquisition coils, as well as other system parameters. We show the applications of CRB in many actual problems related to DT estimation: we compare different gradient field setup schemes proposed in the literature and show how the CRB can be used to choose a convenient one; we show that for fiber-type anisotropy tensors the ellipsoidal area ratio (EAR) can be estimated with less error than other scalar factors such as the fractional anisotropy (FA) or the relative anisotropy (RA), and that for this type of anisotropy tensors, increasing the number of coils is equivalent to increasing the signal-to-noise ratio, i.e., the information of the different coils can be regarded as independent. Also, we present results showing the CRB of several parameters for actual DT-MRI data. We conclude that the CRB is a valuable tool to optimal experiment design in DT-related studies. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1372 / 1383
页数:12
相关论文
共 50 条
  • [1] Anisotropic Diffusion Filtering for Correlated Multiple-Coil MRI
    Vegas-Sanchez-Ferrero, Gonzalo
    Ramos-Llorden, Gabriel
    de Luis-Garcia, Rodrigo
    Tristan-Vega, Antonio
    Aja-Fernandez, Santiago
    [J]. 2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2956 - 2959
  • [2] Diffusion Tensor Imaging with Deterministic Error Bounds
    Artur Gorokh
    Yury Korolev
    Tuomo Valkonen
    [J]. Journal of Mathematical Imaging and Vision, 2016, 56 : 137 - 157
  • [3] Diffusion Tensor Imaging with Deterministic Error Bounds
    Gorokh, Artur
    Korolev, Yury
    Valkonen, Tuomo
    [J]. JOURNAL OF MATHEMATICAL IMAGING AND VISION, 2016, 56 (01) : 137 - 157
  • [4] Reduced data acquisition time in multi-dimensional NMR spectroscopy using multiple-coil probes
    Wang, H
    Ciobanu, L
    Webb, A
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2005, 173 (01) : 134 - 139
  • [5] Effective noise estimation and filtering from correlated multiple-coil MR data
    Aja-Fernandez, Santiago
    Brion, Veronique
    Tristan-Vega, Antonio
    [J]. MAGNETIC RESONANCE IMAGING, 2013, 31 (02) : 272 - 285
  • [6] Multiple echo diffusion tensor acquisition technique
    Sigmund, EE
    Song, YQ
    [J]. MAGNETIC RESONANCE IMAGING, 2006, 24 (01) : 7 - 18
  • [8] Nonlocal maximum likelihood estimation method for denoising multiple-coil magnetic resonance images
    Rajan, Jeny
    Veraart, Jelle
    Van Audekerke, Johan
    Verhoye, Marleen
    Sijbers, Jan
    [J]. MAGNETIC RESONANCE IMAGING, 2012, 30 (10) : 1512 - 1518
  • [9] Noise estimation in single- and multiple-coil magnetic resonance data based on statistical models
    Aja-Fernandez, Santiago
    Tristan-Vega, Antonio
    Alberola-Lopez, Carlos
    [J]. MAGNETIC RESONANCE IMAGING, 2009, 27 (10) : 1397 - 1409
  • [10] Normal-Mode Decomposition of Surface Power Distribution in Multiple-Coil Induction Heating Systems
    Carretero, Claudio
    Acero, Jesus
    Alonso, Rafael
    Burdio, Jose M.
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2016, 52 (02)