Reverse atrial electrical remodelling induced by continuous positive airway pressure in patients with severe obstructive sleep apnoea

被引:30
|
作者
Baranchuk, Adrian [1 ,3 ]
Pang, Helen [1 ]
Seaborn, Geoffrey E. J. [1 ]
Yazdan-Ashoori, Payam [1 ]
Redfearn, Damian P. [1 ]
Simpson, Christopher S. [1 ]
Michael, Kevin A. [1 ]
Fitzpatrick, Michael [2 ]
机构
[1] Queens Univ, Div Cardiol, Kingston Gen Hosp, Kingston, ON K7L 2V7, Canada
[2] Queens Univ, Sleep Disorder Clin, Kingston Gen Hosp, Kingston, ON K7L 2V7, Canada
[3] Queens Univ, EP Training Program, Kingston Gen Hosp, Kingston, ON K7L 2V7, Canada
关键词
Atrial electrical remodelling; CPAP; SAPW; AVERAGED P-WAVE; SINUS RHYTHM; RISK; CARDIOVERSION; FIBRILLATION; ASSOCIATION; RECURRENCE; DISPERSION;
D O I
10.1007/s10840-012-9749-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Obstructive sleep apnoea (OSA) is associated with cardiovascular morbidity and mortality, including atrial arrhythmias. Continuous positive airway pressure (CPAP) is the gold standard treatment for OSA; its impact on atrial electrical remodelling has not been fully investigated. Signal-averaged p-wave (SAPW) duration is an accepted marker for atrial electrical remodelling. The objective of this study is to determine whether CPAP induces reverse atrial electrical remodelling in patients with severe OSA. Consecutive patients attending the Sleep Disorder Clinic at Kingston General Hospital underwent full polysomnography. OSA-negative controls and severe OSA were defined as apnoea-hypopnea index (AHI) < 5 events/hour and AHI a parts per thousand yenaEuro parts per thousand 30 events/hour, respectively. SAPW duration was determined at baseline and after 4-6 weeks of CPAP in severe OSA patients or without intervention controls. Nineteen severe OSA patients and 10 controls were included in the analysis. Mean AHI and minimum oxygen saturation were 41.4 +/- 10.1 events/hour and 80.5 +/- 6.5 % in severe OSA patients and 2.8 +/- 1.2 events/hour and 91.4 +/- 2.1 % in controls. At baseline, severe OSA patients had a greater SAPW duration than controls (131.9 +/- 10.4 vs 122.8 +/- 10.5 ms; p = 0.02). After CPAP, there was a significant reduction of SAPW duration in severe OSA patients (131.9 +/- 10.4 to 126.2 +/- 8.8 ms; p < 0.001), while SAPW duration did not change after 4-6 weeks in controls. CPAP induced reverse atrial electrical remodelling in patients with severe OSA as represented by a significant reduction in SAPW duration.
引用
收藏
页码:247 / 253
页数:7
相关论文
共 50 条
  • [1] Reverse atrial electrical remodelling induced by continuous positive airway pressure in patients with severe obstructive sleep apnoea
    Adrian Baranchuk
    Helen Pang
    Geoffrey E. J. Seaborn
    Payam Yazdan-Ashoori
    Damian P. Redfearn
    Christopher S. Simpson
    Kevin A. Michael
    Michael Fitzpatrick
    [J]. Journal of Interventional Cardiac Electrophysiology, 2013, 36 : 247 - 253
  • [2] Efficacy of daytime continuous positive airway pressure titration in severe obstructive sleep apnoea
    Rudkowski, JC
    Verschelden, P
    Kimoff, RJ
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2001, 18 (03) : 535 - 541
  • [3] Effects of continuous positive airway pressure treatment on cognitive functions in patients with severe obstructive sleep apnoea
    Jurado-Gamez, B.
    Guglielmi, O.
    Gude, F.
    Buela-Casal, G.
    [J]. NEUROLOGIA, 2016, 31 (05): : 311 - 318
  • [4] Continuous positive airway pressure in heart failure patients with obstructive sleep apnoea
    Ferrier, K. A.
    Neill, A. M.
    O'Meeghan, T.
    Richards, M.
    Campbell, A. J.
    [J]. INTERNAL MEDICINE JOURNAL, 2008, 38 (11) : 829 - 836
  • [5] EFFECTIVENESS OF CONTINUOUS POSITIVE AIRWAY PRESSURE ON BLOOD PRESSURE IN PATIENTS WITH OBSTRUCTIVE SLEEP APNOEA
    Zhao Qing
    Liu Zhihong
    Doug, Mcevoy
    Luo Qin
    Zhao Zhihui
    Zhang Hongliang
    Wang Yong
    [J]. HEART, 2010, 96 : A183 - A183
  • [6] Continuous positive airway pressure requirements in patients with tetraplegia and obstructive sleep apnoea
    Le Guen, M. C.
    Cistulli, P. A.
    Berlowitz, D. J.
    [J]. SPINAL CORD, 2012, 50 (11) : 832 - 835
  • [7] Continuous positive airway pressure requirements in patients with tetraplegia and obstructive sleep apnoea
    M C Le Guen
    P A Cistulli
    D J Berlowitz
    [J]. Spinal Cord, 2012, 50 : 832 - 835
  • [8] The Effect of Continuous Positive Airway Pressure on Basal Metabolism Rate in Patients with Severe Obstructive Sleep Apnoea Syndrome
    Onyilmaz, T.
    Baris, S. Argun
    Boyaci, H.
    Basyigit, I
    Dogru, G.
    Yildiz, F.
    [J]. WEST INDIAN MEDICAL JOURNAL, 2021, 69 (01): : 9 - 14
  • [9] Effect of continuous positive airway pressure on ambulatory blood pressure in patients with obstructive sleep apnoea
    Hermida, RC
    Zamarrón, C
    Ayala, DE
    Calvo, C
    [J]. BLOOD PRESSURE MONITORING, 2004, 9 (04) : 193 - 202
  • [10] Continuous positive airway pressure delivery interfaces for obstructive sleep apnoea
    Chai, C. L.
    Pathinathan, A.
    Smith, B.
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2006, (04):