Punching shear tests on flat concrete slabs exposed to fire

被引:19
|
作者
Annerel, E. [1 ]
Lu, L. [1 ]
Taerwe, L. [1 ]
机构
[1] Univ Ghent, Fac Engn & Architecture, Dept Struct Engn, Magnel Lab Concrete Res, B-9052 Ghent, Belgium
关键词
Fire; Flat slab-column connection; Punching shear; Spalling;
D O I
10.1016/j.firesaf.2012.10.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Underground parking structures often consist of flat slabs connected by columns, for which punching shear is often the most critical design criterion. In fire conditions, the punching load can increase due to restraint of the thermal curvature of the slab or due to the expansion of the columns. This increase of the punching load is discussed in the paper by means of a literature review. On the other hand, during fire the punching resistance of the slab decreases due to a gradual reduction of the material properties. This reduction in bearing capacity is studied by means of real scale fire tests, consisting of 6 slabs measuring 3.2 x 3.5 x 0.25 m with a connected column stub and tested for punching shear with a specially designed loading frame. Two reference tests are executed at ambient temperature conditions and four slabs are submitted to ISO 834 curve for 120 min. Comparison of the test data with the expected increased axial load due to thermal restraint found in the literature, shows a potential danger for premature punching failure of flat slab-column connections exposed to fire. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:83 / 95
页数:13
相关论文
共 50 条
  • [1] Punching Shear Behavior of Concrete Flat Slabs in Elevated Temperature and Fire
    Ghoreishi, Mehrafarid
    Bagchi, Ashutosh
    Sultan, Mohamed A.
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (05) : 659 - 674
  • [2] Fire Resistance of Concrete Slabs in Punching Shear
    Liao, Jen-Shou
    Cheng, Fu-Ping
    Chen, Cheng-Chih
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2014, 140 (01)
  • [3] Punching shear of continuous flat reinforced concrete slabs
    Gardner, NJ
    Shao, XY
    [J]. ACI STRUCTURAL JOURNAL, 1996, 93 (02) : 218 - 228
  • [4] Punching shear performance of concrete slabs under fire
    Wang, Dong-ye
    Dong, Yu-li
    Zhang, Da-shan
    Wang, Wei-hua
    Lu, Xin
    [J]. ENGINEERING STRUCTURES, 2020, 225
  • [5] Contribution of concrete and shear reinforcement to the punching shear resistance of flat slabs
    Schmidt, Philipp
    Kueres, Dominik
    Hegger, Josef
    [J]. ENGINEERING STRUCTURES, 2020, 203
  • [6] Shear reinforcement against punching in reinforced concrete flat slabs
    Regan, P.E.
    Samadian, F.
    [J]. Structural Engineer, 2001, 79 (10): : 24 - 31
  • [7] Numerical investigation on punching shear of RC slabs exposed to fire
    Sadaghian, Hamed
    Farzam, Masood
    [J]. COMPUTERS AND CONCRETE, 2019, 23 (03): : 217 - 233
  • [8] Verification of Punching Shear Provisions for Reinforced Concrete Flat Slabs
    Gardner, Noel J.
    [J]. ACI STRUCTURAL JOURNAL, 2011, 108 (05) : 572 - 580
  • [9] Punching shear provisions for reinforced and prestressed concrete flat slabs
    Gardner, NJ
    [J]. CANADIAN JOURNAL OF CIVIL ENGINEERING, 1996, 23 (02) : 502 - 510
  • [10] Shear reinforcement against punching in reinforced concrete flat slabs
    Regan, P.E.
    Samadian, F.
    [J]. Structural Engineer, 2001, 79 (10): : 24 - 31