Bone density: comparative evaluation of Hounsfield units in multislice and cone-beam computed tomography

被引:2
|
作者
de Carvalho Crusoe Silva, Isabela Maria [1 ]
de Freitas, Deborah Queiroz [1 ]
Bovi Ambrosano, Glaucia Maria [2 ]
Boscolo, Frab Norberto [1 ]
Almeida, Solange Maria [1 ]
机构
[1] Univ Estadual Campinas Unicamp, Oral Radiol Area, Dept Oral Diag, Piracicaba Dent Sch, Piracicaba, SP, Brazil
[2] Univ Estadual Campinas Unicamp, Dept Community Dent, Dent Sch Piracicaba, Piracicaba, SP, Brazil
来源
BRAZILIAN ORAL RESEARCH | 2012年 / 26卷 / 06期
关键词
Tomography; X-Ray Computed; Cone-Beam Computed Tomography; Bone Density; Dental Implants; DENTAL IMPLANT SITES; TRABECULAR BONE; ASSESSMENTS; CT; PRINCIPLES; OSTEOTOMY; VALUES;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to evaluate the validity of the bone density value of potential implant sites in HU obtained by a specific cone-beam computed tomography (CBCT) device. In this study, the HU values obtained using a MSCT scanner were used as the gold standard. Twenty mandibles (40 potential implant sites) were scanned using an MSCT scanner (Somatom Sensation 40) and a CBCT scanner (i-CAT). The MSCT images were evaluated using the Syngo CT Workplace software and the CBCT images, using the XoranCat software. The images were evaluated twice by three oral radiologists, at 60 day intervals. The trabecular bone density of the same area was evaluated on both images. Intraclass coefficients (ICC) were calculated to examine the agreement between the examiners and between the two periods of evaluation. The bone density and area of the ROT were compared by the Student t test and Bland-Altman analysis. ICCs were excellent. The mean HU value obtained using CBCT (418.06) was higher than that obtained using MSCT (313.13), with a statistically significant difference (p < 0.0001). In addition, Bland-Altman analysis showed that the HU measures were not equivalent. In conclusion, the bone density in HU with CBCT images obtained using the device studied proved unreliable, since it was higher than that obtained using MSCT.
引用
收藏
页码:550 / 556
页数:7
相关论文
共 50 条
  • [1] Use of Hounsfield units in cone-beam computed tomography
    Farinazzo Vitral, Robert Willer
    Fraga, Marcelo Reis
    da silva Campos, Marcio Jose
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2015, 148 (02) : 204 - 204
  • [2] Comparative analysis of bone density measurements by using multislice spiral and cone-beam computed tomography
    Bal, Cenkhan
    Unsal, Gokce Soganci
    Turkyilmaz, Ilser
    [J]. JOURNAL OF DENTAL SCIENCES, 2020, 15 (03) : 388 - 389
  • [3] Comparative study of jaws with multislice computed tomography and cone-beam computed tomography
    Carrafiello, G.
    Dizonno, M.
    Colli, V.
    Strocchi, S.
    Taubert, S. Pozzi
    Leonardi, A.
    Giorgianni, A.
    Barresi, M.
    Macchi, A.
    Bracchi, E.
    Conte, L.
    Fugazzola, C.
    [J]. RADIOLOGIA MEDICA, 2010, 115 (04): : 600 - 611
  • [4] Computed gray levels in multislice and cone-beam computed tomography
    Azeredo, Fabiane
    de Menezes, Luciane Macedo
    Enciso, Reyes
    Weissheimer, Andre
    de Oliveira, Rogerio Belle
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (01) : 147 - 155
  • [5] Evaluation of voxel values in mandibular cancellous bone: relationship between cone-beam computed tomography and multislice helical computed tomography
    Naitoh, Munetaka
    Hirukawa, Akiko
    Katsumata, Akitoshi
    Ariji, Eiichiro
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (05) : 503 - 506
  • [6] Prospects and challenges of rendering tissue density in Hounsfield units for cone beam computed tomography
    Molteni, Roberto
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 116 (01): : 105 - 119
  • [7] Evaluation of cancellous bone density in the alveolar bone by cone-beam computed tomography in Taiwanese adults
    Chen, Chia-Hui
    Lin, Li-Min
    Chen, Chung-Ho
    Geist, James R.
    Chen, Yuk-Kwan
    [J]. ASIAN BIOMEDICINE, 2013, 7 (06) : 753 - 760
  • [8] Comparison between cone-beam and multislice computed tomography for identification of simulated bone lesions
    Gaia, Bruno Felipe
    Oliveira de Sales, Marcelo Augusto
    Perrella, Andreia
    Fenyo-Pereira, Marlene
    Paraiso Cavalcanti, Marcelo Gusmao
    [J]. BRAZILIAN ORAL RESEARCH, 2011, 25 (04) : 362 - 368
  • [9] Comparison of Cone-Beam Computed Tomography and Multislice Computed Tomography in the Assessment of Extremity Fractures
    Dubreuil, Thibaut
    Mouly, Jerome
    Ltaief-Boudrigua, Aicha
    Martinon, Amanda
    Tilhet-Coartet, Stephane
    Tazarourte, Karim
    Pialat, Jean-Baptiste
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (03) : 372 - 378
  • [10] Artifacts in orthodontic bracket systems in cone-beam computed tomography and multislice computed tomography
    Hirschinger, Veronika
    Hanke, Sebastian
    Hirschfelder, Ursula
    Hofmann, Elisabeth
    [J]. JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2015, 76 (02): : 152 - 163