Ultrasound Image and Augmented Reality Guidance for Off-pump, Closed, Beating, Intracardiac Surgery

被引:13
|
作者
Bainbridge, Daniel [1 ,2 ,3 ]
Jones, Douglas L. [2 ,3 ,5 ,6 ]
Guiraudon, Gerard M. [2 ,3 ,4 ,7 ]
Peters, Terrence M. [2 ,3 ,4 ]
机构
[1] Univ Western Ontario, LHSC, Dept Anesthesiol, London, ON N6A 5A5, Canada
[2] Univ Western Ontario, Canadian Surg Technol & Adv Robot, London, ON, Canada
[3] Univ Western Ontario, Lawson Hlth Res Inst, Imaging Grp, London, ON, Canada
[4] Univ Western Ontario, Robarts Res Inst, London, ON, Canada
[5] Univ Western Ontario, Dept Physiol, London, ON, Canada
[6] Univ Western Ontario, Dept Med Pharmacol, London, ON, Canada
[7] Univ Western Ontario, Dept Surg, London, ON N6A 3K7, Canada
关键词
Image guidance; Virtual reality; Ultrasound image guidance; Off-pump; Minimally invasive; Mitral valve surgery; Transesophageal echocardiography;
D O I
10.1111/j.1525-1594.2008.00639.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Our project is the reintroduction of off-pump intracardiac surgery using the Universal Cardiac Introducer (UCI) for safe intracardiac access. The purpose of this study was to evaluate multimodality visualization using three ultrasound modalities and ultrasound augmented with virtual reality. Image guidance was tested on implanting a mitral valve prosthesis via the UCI in 12 pigs. Initially, two-dimensional (2-D) transesophageal echocardiography (TEE) ultrasound, intravascular ultrasound (intracardiac echocardiography [ICE]), and three-dimensional (3-D) epicardial ultrasound were utilized. Ultrasound augmented with virtual reality was used in the last three experiments. A 2-D TEE assisted navigating the prosthesis into the orifice. Positioning was not intuitive and required trial and error method. A 3-D epicardial ultrasound allowed positioning of the valve into the orifice. Positioning of the clip was difficult because of artifacts with multiple reflections and shadowing. Augmented reality displayed the entire prosthesis and the tools without artifacts; provided intuitive information on navigation, positioning, and orientation of tools; and improved significantly image guidance and surgical skill. Augmented virtual reality, with tracked 2-D or 3-D ultrasound imaging, provides guidance that can effectively substitute for direct vision during beating heart intracardiac surgery.
引用
收藏
页码:840 / 845
页数:6
相关论文
共 50 条
  • [1] Off-pump, beating intracardiac surgery: Development of virtual reality image-guidance using a cardiac phantom
    Guiraudon, G. M.
    Bainbridge, D.
    Moore, J. T.
    Wedlake, C.
    Linte, C.
    Wiles, A.
    Jones, D. L.
    Peters, T. M.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 : 72C - 72C
  • [2] An augmented reality environment for image-guidance of off-pump mitral valve implantation
    Linte, Cristian A.
    Wiles, Andrew D.
    Hill, Nick
    Moore, John
    Wedlake, Chris
    Guiraudon, Gerard
    Jones, Doug
    Bainbridge, Daniel
    Peters, Terry M.
    [J]. MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [3] Modernized off-pump, closed, beating intracardiac surgery: A feasibility study. I: Cardiac access and manipulation of devices
    Guiraudon, Gerald M.
    Jones, Dong L.
    Bainbridge, Daniel
    Peters, Terrence M.
    [J]. CIRCULATION, 2006, 114 (18) : 523 - 524
  • [4] Towards CT Enhanced Ultrasound Guidance for Off-pump Beating Heart Mitral Valve Repair
    Li, Feng P.
    Rajchl, Martin
    White, James A.
    Goela, Aashish
    Peters, Terry M.
    [J]. AUGMENTED REALITY ENVIRONMENTS FOR MEDICAL IMAGING AND COMPUTER-ASSISTED INTERVENTIONS, 2013, 8090 : 136 - 143
  • [5] Augmented Reality Image Guidance During Off-Pump Mitral Valve Replacement Through the Guiraudon Universal Cardiac Introducer
    Guiraudon, Gerard M.
    Jones, Douglas L.
    Bainbridge, Daniel
    Linte, Cristian
    Pace, Danielle
    Moore, John
    Wedlake, Christopher
    Lang, Pencilla
    Peters, Terry M.
    [J]. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2010, 5 (06) : 430 - 438
  • [6] Effects of Clopidogrel in off-pump beating heart surgery
    Maltais, S
    Tetreault, K
    Do, QB
    [J]. CHEST, 2005, 128 (04) : 273S - 273S
  • [7] Fixing the Beating Heart: Ultrasound Guidance for Robotic Intracardiac Surgery
    Howe, Robert D.
    [J]. FUNCTIONAL IMAGING AND MODELING OF THE HEART, PROCEEDINGS, 2009, 5528 : 97 - 103
  • [8] Augmented reality for image guidance in transoral robotic surgery
    Jason Y. K. Chan
    F. Christopher Holsinger
    Stanley Liu
    Jonathan M. Sorger
    Mahdi Azizian
    Raymond K. Y. Tsang
    [J]. Journal of Robotic Surgery, 2020, 14 : 579 - 583
  • [9] Transoral Robotic Surgery: Image Guidance and Augmented Reality
    Pratt, Philip
    Arora, Asit
    [J]. ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY HEAD AND NECK SURGERY, 2018, 80 (3-4): : 204 - 212
  • [10] Augmented reality for image guidance in transoral robotic surgery
    Chan, Jason Y. K.
    Holsinger, F. Christopher
    Liu, Stanley
    Sorger, Jonathan M.
    Azizian, Mahdi
    Tsang, Raymond K. Y.
    [J]. JOURNAL OF ROBOTIC SURGERY, 2020, 14 (04) : 579 - 583