Study on size effect of fibre reinforced polymer retrofitted reinforced concrete beam-column connections under cyclic loading

被引:16
|
作者
Choudhury, A. M. [1 ]
Deb, S. K. [2 ]
Dutta, A. [2 ]
机构
[1] NIT Silchar, Silchar 788010, Assam, India
[2] IIT Guwahati, Dept Civil Engn, Gauhati 781039, Assam, India
关键词
size effect; retrofit; FRP; beam-column; cyclic load; FAILURE; STRENGTH; DUCTILITY; JOINTS; SHEAR;
D O I
10.1139/cjce-2012-0041
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Studies related to size effect are crucial for reliable assessment of behaviour of structural components subjected to dynamic loadings. The available theories of material behaviour that predict size effects are receiving increasing attention in the technical literature nowadays. This paper presents a study on size effect of fibre reinforced polymer retrofitted reinforced concrete beam-column connections based on experimental investigation under displacement controlled cyclic loading. Three different sizes of geometrically similar specimens have been considered to explore the possible existence of size effect. It was observed that the experimental results corroborate closely the size effect law proposed by Bazant in all the cases studied. A parameter, energy dissipation of specimens per unit volume was introduced and its correlations with different drift angles for different sizes of the specimen exhibit the existence of size effect. Comparisons were also made among the tests results of control and retrofitted specimens in terms of gain in ultimate load carrying capacity and existence of size effect was distinctly observed.