Simulation tools for two-dimensional experiments in x-ray computed tomography using the FORBILD head phantom

被引:71
|
作者
Yu, Zhicong [1 ,2 ]
Noo, Frederic [1 ]
Dennerlein, Frank [3 ]
Wunderlich, Adam [1 ]
Lauritsch, Guenter [3 ]
Hornegger, Joachim [2 ]
机构
[1] Univ Utah, Dept Radiol, Salt Lake City, UT 84132 USA
[2] Univ Erlangen Nurnberg, Chair Pattern Recognit, Erlangen, Germany
[3] Siemens AG, Healthcare Sect, Forchheim, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 13期
基金
美国国家卫生研究院;
关键词
RECONSTRUCTION ALGORITHM; MATERIAL DECOMPOSITION; IMAGE-RECONSTRUCTION; BEAM RECONSTRUCTION; OF-INTEREST; CT; PROJECTIONS; REDUCTION; TRANSFORM; INVERSE;
D O I
10.1088/0031-9155/57/13/N237
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Mathematical phantoms are essential for the development and early stage evaluation of image reconstruction algorithms in x-ray computed tomography (CT). This note offers tools for computer simulations using a two-dimensional (2D) phantom that models the central axial slice through the FORBILD head phantom. Introduced in 1999, in response to a need for a more robust test, the FORBILD head phantom is now seen by many as the gold standard. However, the simple Shepp-Logan phantom is still heavily used by researchers working on 2D image reconstruction. Universal acceptance of the FORBILD head phantom may have been prevented by its significantly higher complexity: software that allows computer simulations with the Shepp-Logan phantom is not readily applicable to the FORBILD head phantom. The tools offered here address this problem. They are designed for use with Matlab (R), as well as open-source variants, such as FreeMat and Octave, which are all widely used in both academia and industry. To get started, the interested user can simply copy and paste the codes from this PDF document into Matlab (R) M-files.
引用
收藏
页码:N237 / N252
页数:16
相关论文
共 50 条
  • [1] Two-dimensional X-ray simulation based on Computed Tomography images
    Souza, F. F.
    Martins, T. A. C. P.
    Velho, T. R. D.
    Dalava, B. C.
    Silva, J. V. L.
    [J]. VIRTUAL AND RAPID MANUFACTURING: ADVANCED RESEARCH IN VIRTUAL AND RAPID PROTOTYPING, 2008, : 143 - 147
  • [2] Measurement of Center of Rotation for Projection in X-ray Two-dimensional Computed Tomography System
    Li, Baolei
    Zhang, Yaojun
    Mo, Yang
    [J]. 6TH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2010, 7544
  • [3] Simulation tools for scattering corrections in spectrally resolved x-ray computed tomography using McXtrace
    Busi, Matteo
    Olsen, Ulrik L.
    Knudsen, Erik B.
    Frisvad, Jeppe R.
    Kehres, Jan
    Dreier, Erik S.
    Khalil, Mohamad
    Haldrup, Kristoffer
    [J]. OPTICAL ENGINEERING, 2018, 57 (03)
  • [4] Development of dimensional X-ray computed tomography
    National Metrology Institute of Japan , National Institute of Advanced Industrial Science and Technology , 1-1-1 Umezono, Tsukuba
    Ibaraki
    305-8563, Japan
    [J]. Int. J. Autom. Technol., 5 (567-571):
  • [5] Two-dimensional bioluminescence tomography: numerical simulations and phantom experiments
    Li, Senhu
    Zhang, Qizhi
    Jiang, Huabei
    [J]. APPLIED OPTICS, 2006, 45 (14) : 3390 - 3394
  • [6] Structural analysis of pharmaceutical tablets using two-dimensional X-ray absorption fine-structure spectroscopy and its combination with X-ray computed tomography
    Huang, Zhenni
    Suzuki, Hironori
    Ito, Masataka
    Noguchi, Shuji
    [J]. JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2024, 93
  • [7] ACCUMULATION OF TWO-DIMENSIONAL DATA BLOCKS IN EXPERIMENTS USING STANDING X-RAY WAVES
    KAZIMIROV, AY
    KOVALCHUK, MV
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1987, 30 (05) : 1213 - 1216
  • [8] Feasibility study of endoscopic x-ray luminescence computed tomography: Simulation demonstration and phantom application
    Chen, Xueli
    Liang, Jimin
    Cao, Xin
    Yang, Defu
    Chen, Dongmei
    Ripoll, Jorge
    Tian, Jie
    [J]. JOURNAL OF APPLIED PHYSICS, 2013, 114 (08)
  • [10] TWO-DIMENSIONAL AUTOMATED X-RAY DETECTOR FOR DIFFRACTION EXPERIMENTS.
    Anisimov, Yu.S.
    Zanevskii, Yu.V.
    Ivanov, A.B.
    Movchan, S.A.
    Peshekhonov, V.D.
    Chan Dyk Tkhan'
    Chan Khyu Dao
    Cheremukhina, G.A.
    Chernenko, S.P.
    [J]. Instruments and experimental techniques New York, 1986, 29 (4 pt 1): : 821 - 823