Amino acid analysis using chromatography-mass spectrometry: An inter platform comparison study

被引:60
|
作者
Krumpochova, P. [1 ,2 ]
Bruyneel, B. [1 ]
Molenaar, D. [2 ]
Koukou, A. [1 ]
Wuhrer, M. [1 ]
Niessen, W. M. A. [1 ,4 ]
Giera, M. [2 ,3 ]
机构
[1] Vrije Univ Amsterdam, AIMMS Div BioAnalyt Chem, NL-1081 HV Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Syst Bioinformat AIMMS NISB, NL-1081 HV Amsterdam, Netherlands
[3] Leiden Univ, Med Ctr, Ctr Prote & Metab, NL-2300 RC Leiden, Netherlands
[4] Hyphen MassSpec, NL-2332 XT Leiden, Netherlands
关键词
LC-MS/MS; GC-MS; HILIC; Amino acids; HYDROPHILIC-INTERACTION CHROMATOGRAPHY; PHASE LIQUID-CHROMATOGRAPHY; CAPILLARY-ELECTROPHORESIS; QUANTITATIVE-ANALYSIS; PRECOLUMN DERIVATIZATION; INHERITED DISORDERS; GAS-CHROMATOGRAPHY; MS/MS ANALYSIS; ORGANIC-ACIDS; SEPARATION;
D O I
10.1016/j.jpba.2015.06.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analysis of amino acids has become a central task in many aspects. While amino acid analysis has traditionally mainly been carried out using either gas chromatography (GC) in combination with flame ionization detection or liquid chromatography (LC) with either post-column derivatization using ninhydrin or pre-column derivatization using o-phthalaldehyde, many of today's analysis platforms are based on chromatography in combination with mass spectrometry (MS). While derivatization is mandatory for the GC-based analysis of amino acids, several LC platforms have emerged, particularly in the dawn of targeted metabolite profiling using hydrophilic interaction liquid chromatography (HILIC) coupled to MS, allowing the analysis of underivatized amino acids. Among the numerous analytical platforms available for amino acid analysis today, we here compare three prominent approaches, being GC-MS and LC-MS after amino acid derivatization using chloroformate and HILIC-MS of underivatized amino acids. We compare and discuss practical issues as well as performance characteristics, e.g., the use of C-13-labeled internal standards, of the different platforms and present data on their practical implementation in our laboratory. Finally, we compare the real-life applicability of all three platforms for a complex biological sample. While all three platforms are very-well suited for the analysis of complex biological samples they all show advantages and disadvantages for some analytes as discussed in detail in this manuscript. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:398 / 407
页数:10
相关论文
共 50 条
  • [1] Quantification of amino acid ionic liquids using liquid chromatography-mass spectrometry
    Tang, Fei
    Wu, Kangkang
    Nie, Zhou
    Ding, Li
    Liu, Qian
    Yuan, Jinbin
    Guo, Manli
    Yao, Shouzhuo
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1208 (1-2) : 175 - 181
  • [2] Determination of amino acid isotope enrichment using liquid chromatography-mass spectrometry
    van Eijk, HMH
    Rooyakkers, DR
    Soeters, PB
    Deutz, NEP
    [J]. ANALYTICAL BIOCHEMISTRY, 1999, 271 (01) : 8 - 17
  • [3] A simple ion chromatography-mass spectrometry method for amino acid analysis in beer
    Schmitt, Matthias
    Fillsack, Florian
    Seubert, Andreas
    [J]. JOURNAL OF SEPARATION SCIENCE, 2023, 46 (14)
  • [4] GAS CHROMATOGRAPHY-MASS SPECTROMETRY IN ANALYSIS OF PROTEIN AMINO-ACID COMPOSITION
    RAFTER, JJ
    INGELMANSUNDBERG, M
    GUSTAFSSON, JA
    [J]. ACTA BIOLOGICA ET MEDICA GERMANICA, 1979, 38 (2-3) : 321 - 331
  • [5] COMBINED GAS CHROMATOGRAPHY-MASS SPECTROMETRY OF AMINO ACID DERIVATIVES
    GELPI, E
    KOENIG, WA
    GIBERT, J
    ORO, J
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1969, 7 (10) : 604 - &
  • [6] Classification of natural resins by liquid chromatography-mass spectrometry and gas chromatography-mass spectrometry using chemometric analysis
    Rhourrhi-Frih, B.
    West, C.
    Pasquier, L.
    Andre, P.
    Chaimbault, P.
    Lafosse, M.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1256 : 177 - 190
  • [7] Analysis of Trichothecenes Using Liquid Chromatography-Mass Spectrometry
    James, Kevin J.
    Frahill, James
    Furey, Ambrose
    [J]. FOOD CONTAMINANTS: MYCOTOXINS AND FOOD ALLERGENS, 2008, 1001 : 211 - 240
  • [8] High sensitivity measurement of amino acid isotope enrichment using liquid chromatography-mass spectrometry
    van Eijk, Hans M. H.
    Wijnands, Karolina A. P.
    Bessems, Babs A. F. M.
    Damink, Steven W. Olde
    Dejong, Cornelis H. C.
    Poeze, Martijn
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 905 : 31 - 36
  • [9] Comparison of liquid chromatography-microchip/mass spectrometry to conventional liquid chromatography-mass spectrometry for the analysis of steroids
    Ahonen, Linda
    Keski-Rahkonen, Pekka
    Saarelainen, Taija
    Paviala, Jenni
    Ketola, Raimo A.
    Auriola, Seppo
    Poutanen, Matti
    Kostiainen, Risto
    [J]. ANALYTICA CHIMICA ACTA, 2012, 721 : 115 - 121
  • [10] Metabonomics study of oral cancer using gas chromatography mass spectrometry and liquid chromatography-mass spectrometry
    He Hongbing
    Shi Xianzhe
    Chen Jing
    Gao Peng
    Lei Yayan
    Xu Guowang
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (03) : 245 - 251