Experimental Study to Characterize the Performance of Combined Photovoltaic/Thermal Air Collectors

被引:8
|
作者
Delisle, Veronique [1 ]
Kummert, Michael [2 ]
机构
[1] Nat Resources Canada, CanmetENERGY, Varennes, PQ J3X 1S6, Canada
[2] Ecole Polytech, Montreal, PQ H3C 3A7, Canada
关键词
characterization; equivalent cell temperature; performance; PV/T collector; testing; PLATE;
D O I
10.1115/1.4006576
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Combined photovoltaic/thermal (PV/T) collectors show great potential for reaching the objective of net-zero energy consumption in buildings, but the number of products on the market is still very limited. One of the reasons for the slow market uptake of PV/T collectors is the absence of standardized methods to characterize their performance. Performance characterization is a challenge for PV/T collectors because of the interaction between the thermal and electrical yield. This study addresses this particular issue for PV/T air collectors used in either closed-loop or open-loop configurations. In particular, it presents the potential of the equivalent cell temperature method to determine the temperature of the PV cells in a PV/T air collector and validates models to predict the thermal performance and cell temperature for this particular type of solar collector. Indoor and outdoor experimental tests were performed on two c-Si unglazed PV/T modules. The indoor part of this procedure provided the thermal diode voltage factor and the open-circuit voltage temperature coefficient, two parameters that are essential in the calculation of the equivalent cell temperature. The outdoor procedure consisted of acquiring simultaneous electrical and thermal measurements at various inlet temperatures and flowrates. For the collector used in a closed-loop configuration, thermal efficiency models using the fluid inlet, outlet, or average temperature in the calculation of the reduced temperature provided similar results. For an open-loop configuration, a thermal efficiency model as a function of the fluid outlet flowrate was found to be more appropriate. Using selection of variable methods, it was found that a multiple linear regression model using the fluid inlet temperature, the irradiance, and the fluid outlet temperature as predictive variables could be used to estimate both the PV module back surface average temperature and the equivalent cell temperature. When using the PV temperature predicted by these models in the electrical efficiency model, both PV temperatures showed similar performance. In collectors where the PV back surface temperature is not accessible for temperature sensors mounting, the equivalent cell temperature provides a valuable alternative to be used as the PV temperature. The PV/T collector thermal and electrical performance in either closed-loop or open-loop configurations was found to be encapsulated with a series of five-plots. [DOI: 10.1115/1.4006576]
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A comparative experimental study on the performance of photovoltaic thermal air collectors
    Chen, Yaowen
    Duan, Qiong
    Liu, Yanfeng
    Wang, Dengjia
    Zhuang, Zhaoben
    Qu, Lei
    Dang, Daifeng
    Shi, Lijun
    [J]. APPLIED THERMAL ENGINEERING, 2024, 248
  • [2] Experimental study on the performance of different photovoltaic thermal collectors with nano-technology
    Shakir, Abbas Kadhim
    Hajidavalloo, Ebrahim
    Daneh-Dezfuli, Alireza
    Abdulhaleem, Samer Mohammed
    Obayes, Oras Khudhayer
    [J]. ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2023, 45 (03) : 8458 - 8477
  • [3] Energy and Exergy Study of Effective Parameters on Performance of Photovoltaic/Thermal Natural Air Collectors
    Gholampour, M.
    Ameri, M.
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (03):
  • [4] Photovoltaic thermal air collectors: A review
    Kamthania, Deepali
    Tiwari, G. N.
    [J]. JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2014, 6 (06)
  • [5] Performance analysis of photovoltaic-thermal air collectors combined with a water to air heat exchanger for renewed air conditioning in building
    Hachchadi, Oussama
    Bououd, Mahmoud
    Mechaqrane, Abdellah
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (15) : 18953 - 18962
  • [6] Performance analysis of photovoltaic-thermal air collectors combined with a water to air heat exchanger for renewed air conditioning in building
    Oussama Hachchadi
    Mahmoud Bououd
    Abdellah Mechaqrane
    [J]. Environmental Science and Pollution Research, 2021, 28 : 18953 - 18962
  • [7] Comparative study of the performances of four photovoltaic/thermal solar air collectors
    Hegazy, AA
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (08) : 861 - 881
  • [8] Experimental study of electricity generation by photovoltaic thermal collectors: Comparison with conventioal photovoltaic panels
    Su, Jiachen
    Wang, Shujuan
    Chen, Changhe
    [J]. PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 872 - 875
  • [9] A Thermal Performance Study for Different Glazed Water based Photovoltaic Thermal Collectors
    Sultan, Sakhr M.
    Tso, C. P.
    Efzan, Ervina M. N.
    [J]. GREEN DESIGN AND MANUFACTURE: ADVANCED AND EMERGING APPLICATIONS, 2018, 2030
  • [10] Performance testing of thermal and photovoltaic thermal solar collectors
    Allan, James
    Dehouche, Zahir
    Stankovic, Sinisa
    Mauricette, Lascelle
    [J]. ENERGY SCIENCE & ENGINEERING, 2015, 3 (04): : 310 - 326