Single-Dose Linaclotide Is Equal in Efficacy to Polyethylene Glycol for Bowel Preparation Prior to Capsule Endoscopy

被引:26
|
作者
Stein, Daniel J. [1 ,2 ]
Copland, Andrew [3 ]
McDaniel, Deborah [4 ]
Hays, R. Ann [3 ]
机构
[1] Beth Israel Deaconess Med Ctr, Div Gastroenterol, Dept Internal Med, Boston, MA 02215 USA
[2] Harvard Univ, Boston, MA 02115 USA
[3] Univ Virginia Hlth Syst, Dept Internal Med, Div Gastroenterol & Hepatol, Motil Lab, Charlottesville, VA USA
[4] Univ Virginia, Dept Internal Med, Div Gastroenterol & Hepatol, Charlottesville, VA USA
关键词
Linaclotide; Capsule endoscopy; Capsule endoscopy preparation; DIAGNOSTIC YIELD; DOUBLE-BLIND; SIMETHICONE; TRANSIT; VISUALIZATION;
D O I
10.1159/000496350
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Video capsule endoscopy provides noninvasive visualization of the small bowel, but yield is often limited by debris. At our institution, preparation with polyethylene glycol (PEG) and simethicone is used to improve visualization. Aims: We hypothesized that linaclotide and simethicone would yield equal to better results. Methods: We enrolled 29 subjects for the experimental regimen of linaclotide and simethicone. We maintained standard NPO status, clear liquid period, and simethicone dose. Subjects received 290 mu g of linaclotide 1 h prior to capsule. We randomly selected 30 historical PEG controls. Two blinded gastroenterologists graded visualization as ideal/excellent, good, fair, or poor and measured small bowel transit time. Results: Thirteen men and 16 women were enrolled with an average age of 61. There was no significant difference in exam quality between linaclotide and control. Preparation was rated as ideal/excellent or good in 19 of 28 of linaclotide and 18 of 28 PEG subjects when recorder entered the small bowel (p = 0.78, chisquare). Median small bowel transit was 192 min (linaclotide) versus 202 min (PEG), respectively (p = 0.93, t test). Three studies (1 linaclotide and 2 PEG) failed to leave the stomach; 1 linaclotide subject had recorder failure. Diagnostic yield was similar (18/29 for linaclotide and 16/30 for PEG, p = 0.50, chi-square). There were no serious side effects. No differences in age, sex, BMI, or frequency of diabetes, GERD, or gastroparesis were measured between the groups. Conclusions: Single-dose linaclotide 1 h before capsule endoscopy was equally effective when compared to PEG in terms of visualization and transit time. This trial was registered at ClincialTrials.gov, number NCT02465385. (c) 2019 S. Karger AG, Basel
引用
收藏
页码:297 / 302
页数:6
相关论文
共 50 条
  • [1] Single-Dose Linaclotide Equals Efficacy of Polyethylene Glycol for Video Capsule Endoscopy
    Stein, Daniel J.
    Copland, Andrew P.
    McDaniel, Deborah
    Orton, Charles
    Hays, R. Ann.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2016, 111 : S164 - S164
  • [2] IS BOWEL PREPARATION OF POLYETHYLENE GLYCOL SOLUTION PRIOR TO VIDEO CAPSULE ENDOSCOPY NECESSARY?
    Wu, Jiachuan
    Chen, Ruiyan
    Chen, Xiaodong
    He, Yifeng
    Yang, Xiaoqiao
    Ye, Lifang
    Liang, Biao
    GUT, 2022, 71 : A123 - A123
  • [3] Effect of Bowel Preparation with Polyethylene Glycol on Quality of Capsule Endoscopy
    Park, Sung Chul
    Keum, Bora
    Seo, Yeon Seok
    Kim, Yong Sik
    Jeen, Yoon Tae
    Chun, Hoon Jai
    Um, Soon Ho
    Kim, Chang Duck
    Ryu, Ho Sang
    DIGESTIVE DISEASES AND SCIENCES, 2011, 56 (06) : 1769 - 1775
  • [4] Effect of Bowel Preparation with Polyethylene Glycol on Quality of Capsule Endoscopy
    Sung Chul Park
    Bora Keum
    Yeon Seok Seo
    Yong Sik Kim
    Yoon Tae Jeen
    Hoon Jai Chun
    Soon Ho Um
    Chang Duck Kim
    Ho Sang Ryu
    Digestive Diseases and Sciences, 2011, 56 : 1769 - 1775
  • [5] Single Dose Linaclotide for Capsule Endoscopy Preparation-A Pilot Study
    Stein, Daniel
    Copland, Andrew
    Orton, Charles
    McDaniel, Deborah
    Hays, Rachel
    INFLAMMATORY BOWEL DISEASES, 2016, 22 : S45 - S45
  • [6] Bowel Preparation for Small Bowel Capsule Endoscopy: Is There Still a Role for Polyethylene Glycol?
    Collins, Paul
    Haslam, Neil
    Morris, Anthony
    Skouras, Thomas
    Bond, Ashley
    JOURNAL OF DIGESTIVE ENDOSCOPY, 2020, 11 (03) : 215 - 222
  • [7] Polyethylene Glycol for Small Bowel Capsule Endoscopy
    Yang, Li
    Wang, Xiao
    Gan, Tao
    Wang, Yiping
    Yang, Jinlin
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2017, 2017
  • [8] Usefulness of polyethylene glycol solution with dimethylpolysiloxanes for bowel preparation before capsule endoscopy
    Nouda, Sadaharu
    Morita, Eijiro
    Murano, Mitsuyuki
    Imoto, Akira
    Kuramoto, Takanori
    Inoue, Takuya
    Murano, Naoko
    Toshina, Ken
    Umegaki, Eiji
    Higuchi, Kazuhide
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2010, 25 (01) : 70 - 74
  • [9] Polyethylene glycol plus simethicone in small-bowel preparation for capsule endoscopy
    Spada, Cristiano
    Riccioni, Maria E.
    Familiari, Pietro
    Spera, Gianluca
    Pirozzi, Giuseppe A.
    Marchese, Michele
    Bizzotto, Alessandra
    Ingrosso, Marcello
    Costamagna, Guido
    DIGESTIVE AND LIVER DISEASE, 2010, 42 (05) : 365 - 370
  • [10] Efficacy and Tolerability of Linaclotide Combined with Polyethylene Glycol for Bowel Preparation: A Meta-Analysis
    Shahzil, Muhammad
    Qureshi, Ali Akram
    Hasan, Fariha
    Jamil, Zainab
    Bin Kashif, Talha
    Chaudhry, Ammad Javaid
    Faisal, Muhammad Saad
    Khaqan, Muhammad Ali
    Farooq, Umer
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2024, 119 (10S): : S350 - S351