C-arm flat-panel CT arthrography of the wrist and elbow: first experiences in human cadavers

被引:11
|
作者
Guggenberger, Roman [1 ]
Morsbach, Fabian [1 ]
Alkadhi, Hatem [1 ]
Vich, Magdalena [2 ]
Pfammatter, Thomas [1 ]
Hodler, Juerg [1 ]
Andreisek, Gustav [1 ]
机构
[1] Univ Zurich Hosp, Dept Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Inst Anat, CH-8057 Zurich, Switzerland
关键词
Flat-panel CT; Cone-beam CT; Optimal contrast; Arthrography; Fluoroscopy; COMPUTED-TOMOGRAPHY ARTHROGRAPHY; TRABECULAR STRUCTURE-ANALYSIS; DIAGNOSTIC-ACCURACY; MULTIDETECTOR-CT; IMAGE QUALITY; DETECTOR CT; VOLUME; ARTIFACTS; AGREEMENT;
D O I
10.1007/s00256-012-1501-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To determine the optimal intra-articular iodine concentration for C-arm flat-panel computed tomography (FPCT) arthrography using advanced joint phantoms and to evaluate its application in human cadaveric wrists and elbows. Multi-detector (MD) CT served as the standard of reference. Joint phantoms and 10 human cadaveric wrist and elbow joints were scanned with C-arm FPCT (5-s, 8-s, and 20-s runs) and standard MDCT using different and optimal concentrations of iodinated contrast material. CT numbers of contrast material, tissue, and noise were measured and contrast-to-noise ratios (CNR) calculated for quantitative analysis. Image and depiction of cartilage, bone, and soft tissues were rated. Radiation doses were compared. In FPCT, iodine concentrations positively correlated with CT numbers and noise of contrast material and with radiation dose (r = 0.713-0.996, p < 0.05 each). At an iodine concentration of 45 mg/ml, CNR of cartilage and soft tissues were highest for all FPCT acquisitions and higher than in MDCT. The 20-s FPCT run performed best for image quality and depiction of anatomical structures and was rated overall equal to MDCT (p = 0.857). The optimal iodine concentration for C-arm FPCT arthrography in this study is 45 mg/ml, leading to superior CNR and image quality for an optimal FPCT protocol compared with standard MDCT arthrography in human cadaveric joints.
引用
收藏
页码:419 / 429
页数:11
相关论文
共 50 条
  • [1] C-arm flat-panel CT arthrography of the wrist and elbow: first experiences in human cadavers
    Roman Guggenberger
    Fabian Morsbach
    Hatem Alkadhi
    Magdalena Vich
    Thomas Pfammatter
    Juerg Hodler
    Gustav Andreisek
    [J]. Skeletal Radiology, 2013, 42 : 419 - 429
  • [2] C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance
    Roman Guggenberger
    Erika J. Ulbrich
    Tobias J. Dietrich
    Rosemarie Scholz
    Pascal Kaelin
    Christoph Köhler
    Thilo Elsässer
    Thomas Le Corroller
    Thomas Pfammatter
    Hatem Alkadhi
    Gustav Andreisek
    [J]. European Radiology, 2017, 27 : 454 - 463
  • [3] C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance
    Guggenberger, Roman
    Ulbrich, Erika J.
    Dietrich, Tobias J.
    Scholz, Rosemarie
    Kaelin, Pascal
    Koehler, Christoph
    Elsaesser, Thilo
    Le Corroller, Thomas
    Pfammatter, Thomas
    Alkadhi, Hatem
    Andreisek, Gustav
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (02) : 454 - 463
  • [4] Catheter localization using C-arm with flat-panel
    Meng, Cai
    Zhang, Jun
    Liu, Bo
    Wang, Lijun
    [J]. Gaojishu Tongxin/Chinese High Technology Letters, 2012, 22 (04): : 395 - 402
  • [5] Trabecular structure analysis using C-arm CT: comparison with MDCT and flat-panel volume CT
    Catherine M. Phan
    Eric A. Macklin
    Miriam A. Bredella
    Monica Dadrich
    Paul Flechsig
    Albert J. Yoo
    Joshua A. Hirsch
    Rajiv Gupta
    [J]. Skeletal Radiology, 2011, 40 : 1065 - 1072
  • [6] Trabecular structure analysis using C-arm CT: comparison with MDCT and flat-panel volume CT
    Phan, Catherine M.
    Macklin, Eric A.
    Bredella, Miriam A.
    Dadrich, Monica
    Flechsig, Paul
    Yoo, Albert J.
    Hirsch, Joshua A.
    Gupta, Rajiv
    [J]. SKELETAL RADIOLOGY, 2011, 40 (08) : 1065 - 1072
  • [7] Percutaneous foot joint needle placement using a C-arm flat-panel detector CT
    Martin Wiewiorski
    Martin Thanh Long Takes
    Victor Valderrabano
    Augustinus Ludwig Jacob
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 177 - 180
  • [8] Percutaneous foot joint needle placement using a C-arm flat-panel detector CT
    Wiewiorski, Martin
    Takes, Martin Thanh Long
    Valderrabano, Victor
    Jacob, Augustinus Ludwig
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (02) : 177 - 180
  • [9] Flat-Panel CT Arthrography Feasibility Study and Comparison to Multidetector CT Arthrography
    Guggenberger, Roman
    Fischer, Michael Alexander
    Hodler, Juerg
    Pfammatter, Thomas
    Andreisek, Gustav
    [J]. INVESTIGATIVE RADIOLOGY, 2012, 47 (05) : 312 - 318
  • [10] Percutaneous sacroplasty with the use of C-arm flat-panel detector CT: technical feasibility and clinical outcome
    Sung Eun Kang
    Joon Woo Lee
    Joo Hyung Kim
    Kun Woo Park
    Jin S. Yeom
    Heung Sik Kang
    [J]. Skeletal Radiology, 2011, 40 : 453 - 460