Experimental Evaluation of the Effects of Passive Phase Change Material Walls on the Building Demand Response for Smart Grid Applications

被引:3
|
作者
You, Zhiqiang [1 ,2 ]
Sun, Yongjun [3 ,4 ]
Mo, Shanjun [1 ,2 ]
Zou, Wenke [1 ,2 ]
Zhang, Xu [1 ,2 ]
Gao, Dian-ce [1 ,2 ]
机构
[1] Sun Yat Sen Univ, Sch Intelligent Syst Engn, Shenzhen 518107, Peoples R China
[2] Guangdong Prov Key Lab Fire Sci & Intelligent Eme, Guangzhou 510006, Peoples R China
[3] City Univ Hong Kong, Div Bldg Sci & Technol, Kowloon, Hong Kong, Peoples R China
[4] City Univ Hong Kong, Shenzhen Res Inst, Shenzhen 518057, Peoples R China
基金
中国国家自然科学基金;
关键词
building energy efficiency; phase change material; demand response; precooling temperature; ENERGY; PERSPECTIVE; PERFORMANCE; STRATEGY; SYSTEMS; PRICE;
D O I
10.3390/buildings12111830
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Central air-conditioning systems play a significant role in the demand response (DR) strategies of buildings due to their high energy consumption and flexible energy use. Previous simulation-based studies have shown that the use of phase change materials (PCM) in building envelopes can substantially increase cold storage capacity, which is a key measure for improving the DR performance of buildings. In this study, we experimentally investigated the effect of passive PCM walls on DR performance and conducted quantitative experiments on factors affecting the precooling performance of PCM walls. During DR events, compared to Ordinary walls without a precooling and DR stage, passive PCM walls reduced room cooling loads by 75.05%, electricity consumption by 49.57%, and peak electricity consumption by 31.06%. Additionally, in the precooling period, the impact of the room precooling temperature on passive PCM precooling performance was experimentally studied. When the room precooling temperature was reduced gradually from 21.14 degrees C to 18.24 degrees C, the precooling period could be significantly shortened by between 14.58 and 40.43%, and the room cooling load firstly increased and then decreased, during which the cooling load reduction was up to 13.87%.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] EXPERIMENTAL EVALUATION OF PHASE CHANGE MATERIAL BUILDING WALLS USING SMALL PASSIVE TEST BOXES.
    Collier, R.K.
    Grimmer, D.P.
    IIHR Report (Iowa Institute of Hydraulic Research), 1979, : 547 - 552
  • [2] Evaluation of a fast power demand response strategy using active and passive building cold storages for smart grid applications
    Cui, Borui
    Wang, Shengwei
    Yan, Chengchu
    Xue, Xue
    ENERGY CONVERSION AND MANAGEMENT, 2015, 102 : 227 - 238
  • [3] Numerical simulation and thermal performance of hybrid brick walls embedding a phase change material for passive building applications
    Younsi, Zohir
    Naji, Hassane
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 140 (03) : 965 - 978
  • [4] Numerical simulation and thermal performance of hybrid brick walls embedding a phase change material for passive building applications
    Zohir Younsi
    Hassane Naji
    Journal of Thermal Analysis and Calorimetry, 2020, 140 : 965 - 978
  • [5] Development and experimental evaluation of the wireless illumination controller with demand response for the smart grid
    Choi I.-H.
    Lee J.-H.
    Hong S.-H.
    Transactions of the Korean Institute of Electrical Engineers, 2011, 60 (06): : 1215 - 1224
  • [6] Building power demand response methods toward smart grid
    Wang, Shengwei
    Xue, Xue
    Yan, Chengchu
    HVAC&R RESEARCH, 2014, 20 (06): : 665 - 687
  • [7] Preparation of composite microencapsulated phase change material based on phosphogypsum for passive building applications
    Xu, Dongdong
    Huang, Yun
    Liu, Wenwei
    Sun, Tong
    Zhang, Meiju
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 378
  • [8] Energy consumption of a building with phase change material walls-The effect of phase change material properties
    Imafidon, Oselen J.
    Ting, David S. -K.
    JOURNAL OF ENERGY STORAGE, 2022, 52
  • [9] An Overview of Demand Response Applications under Smart Grid Concept
    Elma, Onur
    Selamogullari, Ugur Savas
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONIC ENGINEERING (ICEEE 2017), 2017, : 104 - 107
  • [10] Optimization of passive application of phase-change materials in building walls
    van der Spoel, W. H.
    Cauberg, J. J. M.
    Research in Building Physics and Building Engineering, 2006, : 433 - 440