Shaking-table tests on seismic behavior of subway station intersecting the ground fissure

被引:10
|
作者
Chen, Xuan [1 ,2 ,3 ]
Xiong, Zhongming [1 ,2 ,3 ]
Zhuge, Yan [4 ]
Chen, Zhi [1 ,2 ,3 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Shaanxi, Peoples R China
[2] Minist Educ XAUAT, Key Lab Struct Engn & Earthquake Resistance, Xian 710055, Shaanxi, Peoples R China
[3] Shaanxi Key Lab Struct & Earthquake Resistance XA, Xian 710055, Shaanxi, Peoples R China
[4] Univ South Australia, UniSA STEM, Adelaide, SA 5095, Australia
基金
中国博士后科学基金;
关键词
Subway station; Ground fissure; Shaking-table test; Seismic response; Damage mechanism; EARTH FISSURE; TUNNELS; DAMAGE; MODEL; SITE;
D O I
10.1016/j.soildyn.2022.107272
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
To investigate the seismic behavior of underground structures in the ground fissure site, a series of shaking-table tests on a subway station intersecting a ground fissure were carried out. Upon investigating the experimental phenomena and test results, propagation of earthquake waves through the soils with ground fissures was characterized and the damage mechanism of the subway station intersecting the ground fissure under earthquakes was studied. The results revealed that the features of wave propagation in soils with ground fissures were different from those in soils without ground fissures, in terms of the intensity, peak instant, and spectrum components. The movement of the subway station intersecting the ground fissure was better controlled by the surrounding soil with a lower input PGA. However, the response of the subway station and surrounding soil was not coordinated under strong earthquakes due to the ground fissure movement. The strain distribution for structural components was related to the position in the soil, and the strains of structural components were generally larger in the hanging-wall than those in the footwall, which was caused by the wave propagation in the ground fissure site. The damage mechanism of subway station intersecting the ground fissure was characterized by the cracks initially produced in the central columns and rapidly developed due to the coupling effect of the shear deformation, compression and bending moment. The bearing capacity of the central columns decreased rapidly, and then the bending moment and shear force at the connections between the slabs and side walls also exceeded the bearing capacity, resulting in the failure of the subway station.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Shaking table tests on seismic response of a subway station structure in ground fissure site
    Chen X.
    Xiong Z.-M.
    Chen Z.
    [J]. Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2022, 44 (02): : 384 - 391
  • [2] SHAKING TABLE TEST AND NUMERICAL SIMULATION ON SUBWAY STATION IN GROUND FISSURE AREA
    Chen X.
    Xiong Z.-M.
    Chen Z.
    [J]. Gongcheng Lixue/Engineering Mechanics, 2023, 40 (07): : 222 - 238
  • [3] Shaking Table Tests on Seismic Responses of Atrium-style Subway Station
    Zhang, Zhi-Ming
    Yu, Hai-Tao
    Yuan, Yong
    Zhao, Hui-Ling
    Bilotta, Emilio
    [J]. Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2021, 34 (05): : 123 - 134
  • [4] Shaking table test on seismic response of subway station structure in soft ground
    Chen Guo-xing
    Chen Su
    Zuo Xi
    Qi Cheng-zhi
    Du Xiu-li
    Wang Zhi-hua
    [J]. ROCK AND SOIL MECHANICS, 2016, 37 (02) : 331 - 342
  • [5] Isolation mechanism of a subway station structure with flexible devices at column ends obtained in shaking-table tests
    Liu, Zhiqian
    Chen, Zhiyi
    Liang, Sunbin
    Li, Chunxiang
    [J]. TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 98
  • [6] Shaking-table tests and numerical simulations on a subway structure in soft soil
    Chen Guoxing
    Chen Su
    Zuo Xi
    Du Xiuli
    Qi Chengzhi
    Wang Zhihua
    [J]. SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2015, 76 : 13 - 28
  • [7] Shaking table tests for cross subway station structure
    Yu Z.
    Zhang H.
    Qiu Y.
    Zhang R.
    Li H.
    [J]. Zhendong yu Chongji/Journal of Vibration and Shock, 2021, 40 (09): : 142 - 151
  • [8] Shaking table test on the seismic failure characteristics of a subway station structure on liquefiable ground
    Chen, Guoxing
    Wang, Zhihua
    Zuo, Xi
    Du, Xiuli
    Gao, Hongmei
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2013, 42 (10): : 1489 - 1507
  • [9] Spatial Effect Analysis on Shaking Table Tests of Subway Station Structure in Liquefiable Ground
    Chen Guo-xing
    Zuo Xi
    Wang Zhi-hua
    Du Xiu-li
    Qi Cheng-zhi
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, PTS 1-3, 2011, 94-96 : 1771 - +
  • [10] Spatial Effect Analysis on Shaking Table Tests of Subway Station Structure in Soft Ground
    Zuo Xi
    Chen Guo-xing
    Wang Zhi-hua
    Du Xiu-li
    [J]. ADVANCES IN CIVIL ENGINEERING AND ARCHITECTURE INNOVATION, PTS 1-6, 2012, 368-373 : 1338 - +