Biocompatible packaging of an epicardial accelerometer for real-time assessment of cardiac motion

被引:7
|
作者
Brancato, L. [1 ]
Weydts, T. [1 ]
Oosterlinck, W. [2 ]
Herijgers, P. [2 ]
Puers, R. [1 ]
机构
[1] Katholieke Univ Leuven, ESAT MICAS, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Cardiovasc Dis, Res Unit Expt Cardiac Surg, Leuven, Belgium
关键词
Epicardial; Accelerometer; Heart motion; Biocompatible packaging; Parylene;
D O I
10.1016/j.proeng.2016.11.152
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
An implantable accelerometer has been developed to monitor the cardiac function and the heart wall motion. The device, to be stitched on the pericardium, can also provide an insight on amplitude and frequency components of the acceleration on different locations on the heart. A commercially available three-axis accelerometer was mounted on a miniature PCB and coated with Parylene-C. The PCB was glued on a laser-cut Teflon structure and then embedded in PDMS. The structural flexibility of the assembly allows the device to adapt to the natural curvature of the muscle and to stretch, therefore not limiting the natural movement of the underlying tissue. The device was tested in-vitro for current leakage and water diffusion. The in-vivo performance was evaluated by recording acceleration signals from the heart of a sheep. (C) 2016 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:80 / 83
页数:4
相关论文
共 50 条
  • [1] Automatic real-time detection of myocardial ischemia by epicardial accelerometer
    Halvorsen, Per Steinar
    Remme, Espen W.
    Espinoza, Andreas
    Skulstad, Helge
    Lundblad, Runar
    Bergsland, Jacob
    Hoff, Lars
    Imenes, Kristin
    Edvardsen, Thor
    Elle, Ole Jakob
    Fosse, Erik
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (04): : 1026 - 1032
  • [2] Automatic real-time detection of myocardial ischemia by epicardial accelerometer
    P Halvorsen
    E Remme
    A Espinoza
    L Hoff
    H Skulstad
    T Edvardsen
    E Fosse
    [J]. Critical Care, 13 (Suppl 1):
  • [3] Biocompatible packaging and testing of an endocardial accelerometer for heart wall motion analysis
    Brancato, L.
    Weydts, T.
    De Clercq, H.
    Dimiaux, T.
    Herijgers, P.
    Puers, R.
    [J]. EUROSENSORS 2015, 2015, 120 : 840 - 844
  • [4] Accelerometer Based Real-Time Remote Detection and Monitoring of Hand Motion
    Pang, J.
    Singh, I.
    [J]. WORLD CONGRESS ON ENGINEERING AND COMPUTER SCIENCE, WCECS 2011, VOL II, 2011, : 744 - 747
  • [5] Real-Time Epicardial Excitation Time Map Overlay
    de Lange, Paul
    Takata, Yuhei
    Kim, Hongho
    Liao, Hongen
    Kobayashi, Etsuko
    Ono, Minoru
    Kyo, Shunei
    Takamoto, Shinichi
    Ishii, Satoshi
    Asano, Takeo
    Sakuma, Ichiro
    [J]. MEDICAL IMAGING AND AUGMENTED REALITY, 2010, 6326 : 521 - +
  • [6] REAL TIME MONITORING OF LEFT VENTRICULAR PERFORMANCE WITH AN EPICARDIAL ACCELEROMETER SENSOR
    Hyler, S.
    Halvorsen, P. S.
    Espinoza, A.
    Hoff, L.
    Edvardsen, T.
    Skulstad, H.
    Fosse, E.
    [J]. INTENSIVE CARE MEDICINE, 2009, 35 : 236 - 236
  • [7] Epicardial real-time three-dimensional echocardiography in cardiac surgery:: A preliminary experience
    De Castro, Stefano
    Salandin, Valeria
    Cavarretta, Elena
    Salvador, Loris
    Valfre, Carlo
    Caselli, Stefano
    Di Michele, Sara
    Faletra, Francesco
    Pandian, Natesa G.
    [J]. ANNALS OF THORACIC SURGERY, 2006, 82 (06): : 2254 - 2259
  • [8] Real-Time Error Estimation for Real-Time Motion Prediction
    Moore, D.
    Sawant, A.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3711 - 3711
  • [9] HISTOTRIPSY CARDIAC THERAPY SYSTEM INTEGRATED WITH REAL-TIME MOTION CORRECTION
    Miller, Ryan M.
    Kim, Yohan
    Lin, Kuang-Wei
    Cain, Charles A.
    Owens, Gabe E.
    Xu, Zhen
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (12): : 2362 - 2373
  • [10] Using Motion Correction to Improve Real-Time Cardiac MRI Reconstruction
    Bilgazyev, E.
    Uyanik, I.
    Unan, M.
    Shah, Dipan
    Tsekos, Nikolaos V.
    Leiss, E. L.
    [J]. SIXTH INTERNATIONAL CONFERENCE ON MACHINE VISION (ICMV 2013), 2013, 9067