Semi-automated computed tomography Volumetry can predict hemihepatectomy specimens' volumes in patients with hepatic malignancy

被引:12
|
作者
Mayer, Philipp [1 ]
Grozinger, Martin [1 ]
Mokry, Theresa [1 ]
Schemmer, Peter [2 ,3 ]
Waldburger, Nina [4 ]
Kauczor, Hans-Ulrich [1 ]
Klauss, Miriam [1 ]
Sommer, Christof-Matthias [1 ]
机构
[1] Univ Hosp Heidelberg, Dept Diagnost & Intervent Radiol, Heidelberg, Germany
[2] Univ Hosp Heidelberg, Dept Gen & Transplant Surg, Heidelberg, Germany
[3] Med Univ Graz, Div Transplant Surg, Dept Surg, Graz, Austria
[4] Univ Hosp Heidelberg, Inst Pathol, Heidelberg, Germany
关键词
Computed tomography volumetry; Hemihepatectomy; Hepatic malignancy; DONOR LIVER-TRANSPLANTATION; SLICE THICKNESS; CT-VOLUMETRY; DYSFUNCTION; REMNANT; WEIGHT;
D O I
10.1186/s12880-019-0309-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundOne of the major causes of perioperative mortality of patients undergoing major hepatic resections is post-hepatectomy liver failure (PHLF). For preoperative appraisal of the risk of PHLF it is important to accurately predict resectate volume and future liver remnant volume (FLRV). The objective of our study is to prospectively evaluate the accuracy of hemihepatectomy resectate volumes that are determined by computed tomography volumetry (CTV) when compared with intraoperatively measured volumes and weights as gold standard in patients undergoing hemihepatectomy.MethodsTwenty four patients (13 women, 11 men) scheduled for hemihepatectomy due to histologically proven primary or secondary hepatic malignancies were included in our study. CTV was performed using a semi-automated module (S, hereinafter) (syngo.CT Liver Analysis VA30, Siemens Healthcare, Germany). Conversion factors between CT volumes on the one side and intraoperative volumes and weights on the other side were calculated using the method of least squares. Absolute and relative disagreements between CT volumes and intraoperative volumes were determined.ResultsA conversion factor of c=0.906 most precisely predicted intraoperative volumes of exsanguinated hemihepatectomy specimens from CT volumes in all patients with mean absolute and relative disagreements between CT volumes and intraoperative volumes of 57ml and 6.3%. The use of operation-specific conversion factors yielded even better results.ConclusionsCTV performed with S accurately predicts intraoperative volumes of hemihepatectomy specimens when applying conversion factors which compensate for exsanguination. This allows to precisely estimate the FLRV and thus minimize the risk of PHLF in patients undergoing major hepatic resections.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Semi-automated computed tomography Volumetry can predict hemihepatectomy specimens’ volumes in patients with hepatic malignancy
    Philipp Mayer
    Martin Grözinger
    Theresa Mokry
    Peter Schemmer
    Nina Waldburger
    Hans-Ulrich Kauczor
    Miriam Klauss
    Christof-Matthias Sommer
    [J]. BMC Medical Imaging, 19
  • [2] Semi-automated Noninvasive Coronary Plaque Volumetry by 64-Row Multidetector Computed Tomography
    Kijima, Yoshiyuki
    Akutagawa, Osamu
    Sakai, Taku
    Kume, Kiyoshi
    Okura, Akira
    Hata, Takeshi
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A274 - A275
  • [3] Dose Reduction for Semi-Automated Volumetry of Hepatic Metastasis in MDCT Studies
    Keil, Sebastian
    Plumhans, Cedric
    Nagy, Istvan A.
    Schiffl, Katharina
    Soza, Grzegorz
    Behrendt, Florian F.
    Mahnken, Andreas H.
    Guenther, Rolf W.
    Das, Marco
    [J]. INVESTIGATIVE RADIOLOGY, 2010, 45 (02) : 77 - 81
  • [4] Semi-automated volumetry of MRI serves as a biomarker in neuromuscular patients
    Mueller, Madlaine
    Dohrn, Maike F.
    Romanzetti, Sandro
    Gadermayr, Michael
    Reetz, Kathrin
    Kraemer, Nils A.
    Kuhl, Christiane
    Schulz, Joerg B.
    Gess, Burkhard
    [J]. MUSCLE & NERVE, 2020, 61 (05) : 600 - 607
  • [5] Computed Tomography Volumetry of Bone Cement: Retrospective Blinded Validation of Commercially Available Semi-automated Edge Detection Software
    Sag, Alan A.
    Barral, Ernest
    Thompson, Russell E.
    Goodwin, C. Rory
    Ronald, James
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (04) : 669 - 672
  • [6] SEMI-AUTOMATED MUSCLE MRI-VOLUMETRY FOR MYOPATHY AND NEUROPATHY PATIENTS
    Mueller, M.
    Dohrn, M.
    Romanzetti, S.
    Reetz, K.
    Gess, B.
    [J]. JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2017, 22 (03) : 344 - 344
  • [7] Automated and semi-automated procedures in the assessment of Coronary Arterial Disease by Computed Tomography
    Ribeiro, M. M.
    Bate, I.
    Goncalves, N.
    O'Neill, J.
    Mauricio, J. C.
    [J]. COMPUTATIONAL MODELLING OF OBJECTS REPRESENTED IN IMAGES: FUNDAMENTALS, METHODS AND APPLICATIONS III, 2012, : 229 - 234
  • [8] A semi-automated approach for measuring splenic injury using computed tomography
    Danelson, Kerry A.
    Hoth, J. Jason
    Miller, Preston R.
    Stitzel, Joel D.
    [J]. Biomedical Sciences Instrumentation, Vol 43, 2007, 43 : 13 - 17
  • [9] Semi-automated carotid lumen segmentation in computed tomography angiography images
    Hamid Reza Hemmati
    Mahdi Alizadeh
    Alireza Kamali-Asl
    Shapour Shirani
    [J]. The Journal of Biomedical Research, 2017, 31 (06) : 548 - 558
  • [10] Correlation between computed tomography angiography and histology of carotid artery atherosclerosis: Can semi-automated imaging software predict a plaque's composition?
    Benson, John C.
    Nardi, Valentina
    Bois, Melanie C.
    Saba, Luca
    Brinjikji, Waleed
    Savastano, Luis
    Lanzino, Giuseppe
    Lerman, Amir
    [J]. INTERVENTIONAL NEURORADIOLOGY, 2022, 28 (03) : 332 - 337