共 50 条
Immediately loaded machined versus rough surface dental implants in edentulous jaws: One-year post-loading results of a pilot randomised controlled trial
被引:0
|作者:
Esposito, Marco
[1
]
Felice, Pietro
[2
]
Barausse, Carlo
[2
]
Pistilli, Roberto
[3
]
Grandi, Giovanni
[4
]
Simion, Massimo
[5
]
机构:
[1] Univ Gothenburg, Sahlgrenska Acad, Dept Biomat, Gothenburg, Sweden
[2] Univ Bologna, Dept Periodontol & Implantol, Bologna, Italy
[3] San Filippo Nen Hosp, Oral & Maxillofacial Unit, Rome, Italy
[4] Univ Modena & Reggio Emilia, Dept Obstet Gynaecol & Paediat, Modena, Italy
[5] Univ Milan, Dept Periodontol & Implant Rehabil, Milan, Italy
关键词:
full edentulism;
immediately loaded machined dental implants;
roughened dental implants;
OSSEOINTEGRATED ORAL IMPLANTS;
FIXED PARTIAL DENTURES;
SPLIT-MOUTH;
BRANEMARK;
FAILURES;
TORQUE;
D O I:
暂无
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
Purpose: To compare the effectiveness of immediately loaded total prostheses supported by implants with a roughened surface versus implants with a machined/turned surface. Materials and methods: Fifty edentulous or to-be-rendered edentulous patients requiring an implant-supported cross-arch prosthesis, were randomised either to receive four to eight implants with a roughened surface (25 patients) or with a machined/turned surface (25 patients). Provisional metal-reinforced acrylic prostheses were delivered 48 h after implant placement. Provisional prostheses were replaced after 4 months, by definitive screw-retained metal-resin cross-arch restorations. Outcome measures were prosthesis and implant failures, any complications and pen-implant marginal bone level changes. Patients were followed 1 year after loading. Results: One year after loading no patient dropped out. No prosthesis failed, but two machined implants were found to be mobile at definitive impression taking in 1 patient (Fisher's exact test: P = 0.312; difference in proportions = 4%; 95% Cl: -10 to 18). No complications occurred. Both groups presented a significant pen-implant marginal bone loss at 1 year after loading (P < 0.0001), -0.64 0.20 mm for rough implants and -0.68 0.23 mm for turned implants, respectively, with no statistically significant differences between the two groups (P = 0.482; mean difference = 0.04 mm; 95% Cl: -0.17 to 0.25). Conclusions: Up to 1 year after immediate loading, both implant surfaces provided good and similar results, however; the only two implants which failed early in the same patient had a machined surface. These preliminary results must be confirmed by larger trials with longer follow-ups.