摘要
The calculation of voltages induced by indirect lightning on multiconductor lines has been the subject of several studies, The reported conclusions are not always in agreement with each other, In this paper, using a modeling procedure presented in a previous work, we study the shielding effect due to mutual coupling among the conductors of a three-phase line and between the ground wires and the line conductors. The results are compared with those published by other authors, and explanations of the disagreements are given, Additionally, a simplified method to evaluate lightning-induced voltages on a multiconductor line from the values obtained for the single conductor case is presented, and a simple formula which gives the magnitude reduction of the induced voltages due to the presence of other conductors is derived. It is shown that, for the examined case, the derived simple formula gives practically the same results as those obtained using the rigorous procedure. We have also compared results obtained using the simplified formula proposed by Rusck to evaluate the protective ratio of a ground wire with our results, and we have found that the values predicted by the Rusck formula are about 6% lower than ours.
引用
收藏
页码:1404 / 1411
页数:8
相关论文
共 50 条
  • [1] Response of multiconductor power lines to nearby lightning return stroke electromagnetic fields
    Rachidi, F
    Nucci, CA
    Ianoz, M
    Mazzetti, C
    [J]. 1996 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE PROCEEDINGS, 1996, : 294 - 301
  • [2] Overvoltage induced in overhead power lines by nearby lightning stroke
    Maslowski, Grzegorz
    Ziemba, Robert
    Kossowski, Tomasz
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2018, 94 (02): : 41 - 44
  • [3] Electromagnetic fields at the top of a tall building associated with nearby lightning return strokes
    Baba, Yoshihiro
    Rakov, Vladimir A.
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2007, 49 (03) : 632 - 643
  • [4] A MRTD Model for calculating Lightning return stroke electromagnetic fields
    Jiang, Zhi-dong
    Zhou, Bi-hua
    Liu, Ya-wen
    Yang, Bo
    [J]. 2012 6TH ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS (CEEM' 2012), 2012, : 242 - 245
  • [5] Computation of radiated electromagnetic fields from a lightning return stroke
    Kannu, PD
    Thomas, MJ
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC INTERFERENCE AND COMPATIBILITY, 2003, : 129 - 132
  • [6] Electromagnetic Fields of a Lightning Return Stroke in Presence of a Stratified Ground
    Mimouni, Abdenbi
    Rachidi, Farhad
    Rubinstein, Marcos
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2014, 56 (02) : 413 - 418
  • [7] THE EFFECT OF THE LIGHTNING RETURN STROKE SPEED ON VOLTAGES INDUCED ON NEARBY OVERHEAD LINES
    Mashayekhi, V.
    Moini, R.
    Sadeghi, S. H. H.
    [J]. 2010 30TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2010,
  • [8] Currents and electromagnetic fields of selected "engineering" models of lightning return stroke
    Aniserowicz, K
    [J]. OVERVOLTAGES IN POWER, ELECTRONIC, COMPUTER AND ENGINEERING, 2005, : 33 - 38
  • [9] Electromagnetic Fields of Lightning Return Stroke in Presence of a Vertically Stratified Ground
    VenuGopal, B.
    Chandrasekaran, K.
    [J]. 2017 INTERNATIONAL CONFERENCE OF ELECTRONICS, COMMUNICATION AND AEROSPACE TECHNOLOGY (ICECA), VOL 1, 2017, : 679 - 683
  • [10] Effect on Lightning Electromagnetic Fields from the Return-Stroke Parameters
    Chen Yazhou
    Wang Xiaojia
    Wan Haojiang
    Zhou Xing
    [J]. 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC), 2012, : 99 - 102