An Ear-Worn Sensor for the Detection of Gait Impairment After Abdominal Surgery

被引:9
|
作者
Atallah, Louis [1 ]
Aziz, Omer [1 ]
Gray, Edward [1 ]
Lo, Benny [1 ]
Yang, Guang-Zhong [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Hamlyn Ctr, Inst Global Hlth Innovat, London SW7 2BZ, England
基金
英国工程与自然科学研究理事会;
关键词
body sensor networks; impairment; recovery; postoperative; ACCELEROMETERS; INFORMATION; PARAMETERS; PATTERNS; WALKING; TRUNK; HEAD;
D O I
10.1177/1553350612445639
中图分类号
R61 [外科手术学];
学科分类号
摘要
Surgery to the trunk often results in a change of gait, most pronounced during walking. This change is usually transient, often as a result of wound pain, and returns to normal as the patient recovers. Quantifying and monitoring gait impairment therefore represents a novel means of functional postoperative home recovery follow-up. Until now, this type of assessment could only be made in a gait lab, which is both expensive and labor intensive to administer on a large scale. The objective of this work is to validate the use of an ear-worn activity recognition (e-AR) sensor for quantification of gait impairment after abdominal wall and perianal surgery. The e-AR sensor was used on 2 comparative simulated data sets (N = 32) of truncal impairment to observe walking patterns. The sensor was also used to observe the walking patterns of preoperative and postoperative surgical patients who had undergone abdominal wall (n = 5) and perianal surgery (n = 5). Methods for multiresolution feature extraction, selection, and classification are investigated using the raw ear-sensor data. Results show that the method demonstrates a good separation between impaired and nonimpaired classes for both simulated and real patient data sets. This indicates that the e-AR sensor may be used as a tool for the pervasive assessment of postoperative gait impairment, as part of functional recovery monitoring, in patients at their own homes.
引用
收藏
页码:86 / 94
页数:9
相关论文
共 50 条
  • [1] Detecting Walking Gait Impairment with an Ear-worn Sensor
    Atallah, Louis
    Lo, Benny
    Yang, Guang-Zhong
    Aziz, Omer
    [J]. SIXTH INTERNATIONAL WORKSHOP ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS, PROCEEDINGS, 2009, : 175 - +
  • [2] Gait asymmetry detection in older adults using a light ear-worn sensor
    Atallah, L.
    Wiik, A.
    Lo, B.
    Cobb, J. P.
    Amis, A. A.
    Yang, G-Z
    [J]. PHYSIOLOGICAL MEASUREMENT, 2014, 35 (05) : N29 - N40
  • [3] Feature Extraction from Ear-Worn Sensor Data for Gait Analysis
    Li, Ling
    Atallah, Louis
    Lo, Benny
    Yang, Guang-Zhong
    [J]. 2014 IEEE-EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL AND HEALTH INFORMATICS (BHI), 2014, : 560 - 563
  • [4] Validation of an Ear-Worn Wearable Gait Analysis Device
    Jung, Chang Keun
    Kim, Jinkyuk
    Rhim, Hye Chang
    [J]. SENSORS, 2023, 23 (03)
  • [5] Mobile Spatiotemporal Gait Segmentation Using an Ear-Worn Motion Sensor and Deep Learning
    Decker, Julian
    Boborzi, Lukas
    Schniepp, Roman
    Jahn, Klaus
    Wuehr, Max
    [J]. Sensors, 2024, 24 (19)
  • [6] A novel gait parameter estimation method for healthy adults and postoperative patients with an ear-worn sensor
    Diao, Yanan
    Ma, Yu
    Xu, Dongyan
    Chen, Wei
    Wang, Yuanyuan
    [J]. PHYSIOLOGICAL MEASUREMENT, 2020, 41 (05)
  • [7] Validation of an ear-worn sensor for gait monitoring using a force-plate instrumented treadmill
    Atallah, Louis
    Wiik, Anatole
    Jones, Gareth G.
    Lo, Benny
    Cobb, Justin P.
    Amis, Andrew
    Yang, Guang-Zhong
    [J]. GAIT & POSTURE, 2012, 35 (04) : 674 - 676
  • [8] Gait Analysis From a Single Ear-Worn Sensor: Reliability and Clinical Evaluation for Orthopaedic Patients
    Jarchi, Delaram
    Lo, Benny
    Wong, Charence
    Ieong, Edmund
    Nathwani, Dinesh
    Yang, Guang-Zhong
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2016, 24 (08) : 882 - 892
  • [9] An Ear-worn Continuous Ballistocardiogram (BCG) Sensor for Cardiovascular Monitoring
    Da He, David
    Winokur, Eric S.
    Sodini, Charles G.
    [J]. 2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 5030 - 5033
  • [10] Energy Expenditure Prediction Using a Miniaturized Ear-Worn Sensor
    Atallah, Louis
    Leong, Julian J. H.
    Lo, Benny
    Yang, Guang-Zhong
    [J]. MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2011, 43 (07) : 1369 - 1377