Post-combustion CO2 capture by coupling [emim] cation based ionic liquids with a membrane contactor; Pseudo-steady-state approach

被引:25
|
作者
Sohaib, Qazi [1 ]
Vadillo, Jose Manuel [2 ]
Gomez-Coma, Lucia [2 ]
Albo, Jonathan [2 ]
Druon-Bocquet, Stephanie [1 ]
Irabien, Angel [2 ]
Sanchez-Marcano, Jose [1 ]
机构
[1] Univ Montpellier, ENSCM, Inst Europeen Membranes, CNRS,ENSCM,IEM UMR 5635, Montpellier, France
[2] Univ Cantabria, Chem & Biomol Engn Dept, Ave Castros, Santander 39005, Spain
关键词
Post-combustion CO2 capture; Pseudo-steady-state; Membrane contactor; Ionic liquid; Absorption kinetics; WATER-BASED NANOFLUIDS; OF-THE-ART; CARBON-DIOXIDE; ABSORPTION PROCESS; TEMPERATURE-DEPENDENCE; AQUEOUS-SOLUTIONS; SURFACE-TENSION; AMINE SOLUTION; SEPARATION; PRESSURE;
D O I
10.1016/j.ijggc.2020.103076
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study demonstrates the coupling of Ionic liquids (ILs) with a membrane contactor for post-combustion CO2 capture at moderate pressures and temperatures. ILs 1-ethyl-3-methylimidazolium methyl sulfate([emim] [MeSO4]), 1-ethyl-3-methylimidazolium dicyanamide([emim][DCA]), 1-ethyl-3-methylimidazolium ethyl sulfate([emim][EtSO4]) and 1-ethyl-3-methylimidazolium acetate ([emim][Ac]) were selected due to their high thermal stability, moderate viscosity and surface tension, as well as high CO2 solubility. No wetting conditions were confirmed for the polypropylene membrane by measuring contact angle, liquid entry pressure (LEP) and SEM of fiber surface before and after the operation. ILs were recirculated in the setup until reaching pseudo steady-state. All four ILs were able to capture a substantial amount of CO2 during the specified operation time. Initially, very high values of CO2 mass transfer flux and experimental overall mass transfer coefficient were obtained which further decreased with operation time and reached a nearly constant value at pseudo-steadystate. Effect of CO2 loading of the ILs and temperature on enhancement factor and first order rate constant were evaluated. The absorption behavior and kinetics were strongly influenced by the CO2 concentration in the ILs, which divides the absorption process in two steps; an initial faster absorption at the gas-liquid interface and later slower absorption in the bulk of the IL. Finally, a pseudo-steady-state modelling approach was implemented and validated.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Ionic liquids as an alternative to CO2 post-combustion capture
    Gimeno, M. P.
    Mayoral, M. C.
    Andres, J. M.
    BOLETIN DEL GRUPO ESPANOL DEL CARBON, 2013, (30): : 2 - 5
  • [2] Phase change ionic liquids for post-combustion CO2 capture
    Brennecke, Joan
    Seo, Samuel
    Simoni, Lluke
    Stadtherr, Mark
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [3] Recyclability of Encapsulated Ionic Liquids for Post-Combustion CO2 Capture
    Song, Tangqiumei
    Bonilla, Gabriela M. Avelar
    Morales-Collazo, Oscar
    Lubben, Michael J.
    Brennecke, Joan F.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2019, 58 (12) : 4997 - 5007
  • [4] Ionic liquids with aprotic heterocyclic anions for post-combustion CO2 capture
    Goodrich, Brett
    Seo, Samuel
    Wilson, Levi
    Ficke, Lindsay
    Massel, Marjorie
    Zadigian, David
    Brennecke, Joan F.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [5] Ionic liquids for post-combustion CO2 absorption
    Wappel, D.
    Gronald, G.
    Kalb, R.
    Draxler, J.
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2010, 4 (03) : 486 - 494
  • [6] A dense membrane contactor for intensified CO2 gas/liquid absorption in post-combustion capture
    Nguyen, P. T.
    Lasseuguette, E.
    Medina-Gonzalez, Y.
    Remigy, J. C.
    Roizard, D.
    Favre, E.
    JOURNAL OF MEMBRANE SCIENCE, 2011, 377 (1-2) : 261 - 272
  • [7] Modelling strategies of membrane contactor processes for CO2 post-combustion capture: A critical reassessment
    Chabanon, E.
    Roizard, D.
    Favre, E.
    EUROMEMBRANE CONFERENCE 2012, 2012, 44 : 343 - 346
  • [8] Post-combustion CO2 capture with biomimetic membrane
    Thibaud-Erkey, Catherine
    Cordatos, Harry
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 241
  • [9] Scale-up of PEEK hollow fiber membrane contactor for post-combustion CO2 capture
    Li, Shiguang
    Pyrzynski, Travis J.
    Klinghoffer, Naomi B.
    Tamale, Timothy
    Zhong, Yongfang
    Aderhold, James L.
    Zhou, S. James
    Meyer, Howard S.
    Ding, Yong
    Bikson, Benjamin
    JOURNAL OF MEMBRANE SCIENCE, 2017, 527 : 92 - 101
  • [10] Membrane gas-solvent contactor pilot plant trials for post-combustion CO2 capture
    Scholes, Colin A.
    Kentish, Sandra E.
    Qader, Abdul
    SEPARATION AND PURIFICATION TECHNOLOGY, 2020, 237