Retention of Tc-99m ECD in delayed SPECT of the brain

被引:6
|
作者
Flores, LG [1 ]
Jinnouchi, S [1 ]
Nagamachi, S [1 ]
Ohnishi, T [1 ]
Futami, S [1 ]
Nakahara, H [1 ]
Shimoshinbara, S [1 ]
Ushinbana, K [1 ]
Tamura, S [1 ]
机构
[1] Miyazaki Med Coll, Dept Radiol, Kiyotake, Miyazaki 8891692, Japan
关键词
Tc-99m ECD; SPECT; retention rate;
D O I
10.1007/BF03165420
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We determined the effect of retention on the changes in regional biodistribution of Tc-99m ECD in the brain. A total of 14 cases, 7 normal volunteers and 7 patients with various diagnoses but with very minimal radiologic findings or none were included in the study. SPECT images were taken at 30 min, 1, 2, 3, 4 and 6 hrs after an intravenous injection. Retention rates were calculated in various regions and were corrected according to the time decay of technetium. There was a tendency for the retention rate to increase up to three hours of imaging and then a decrease was noted in most regions of the brain. In the thalamus, increasing retention was noted. In conclusion, Tc-99m ECD retention in the different regions of the brain varies with time. These differences should always be considered when planning and interpreting SPECT quantitative studies.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 50 条
  • [1] Retention of Tc-99m ECD in delayed SPECT of the brain
    Leo G. Flores
    Seishi Jinnouchi
    Shigeki Nagamachi
    Takashi Ohnishi
    Shigemi Futami
    Hiroshi Nakahara
    Shigeru Shimoshinbara
    Kenji Ushinbana
    Shozo Tamura
    Annals of Nuclear Medicine, 1999, 13 : 1 - 4
  • [2] Early and delayed Tc-99m ECD brain SPECT in SLE patients with CNS involvement
    Kaoru Kikukawa
    Hiroshi Toyama
    Masao Katayama
    Tetsuhiro Nishimura
    Kazutaka Ejiri
    Kazuyuki Minami
    Kaname Matsumura
    Hitomi Miyama
    Yutaka Emoto
    Hisato Maeda
    Kohei Senda
    Akira Takeuchi
    Hisaji Oshima
    Shunji Yoshida
    Katsutaka Torikai
    Sukehiko Koga
    Annals of Nuclear Medicine, 2000, 14 : 25 - 32
  • [3] Early and delayed Tc-99m ECD brain SPECT in SLE patients with CNS involvement
    Kikukawa, K
    Toyama, H
    Katayama, M
    Nishimura, T
    Ejiri, K
    Minami, K
    Matsumura, K
    Miyama, H
    Emoto, Y
    Maeda, H
    Senda, K
    Takeuchi, A
    Oshima, H
    Yoshida, S
    Torikai, K
    Koga, S
    ANNALS OF NUCLEAR MEDICINE, 2000, 14 (01) : 25 - 32
  • [4] RETENTION OF TC-99M ECD IN THE BRAIN IS RELATED TO INVIVO METABOLISM
    WALOVITCH, RC
    MAKUCH, J
    KNAPIK, G
    WATSON, AD
    WILLIAMS, SJ
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1988, 14 (5-6): : 227 - 227
  • [5] Tc-99m ECD brain SPECT in patients with acute stroke.
    Ghesani, M
    DePuey, EG
    Friedman, M
    Frazzini, V
    Braun, C
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 40 - 40
  • [6] Superiority of Tc-99m ECD brain SPECT to Tc-99m HMPAO brain SPECT in localizing the infarction zone in the same brains with subacute stroke
    Hyun, I.
    Lee, J.
    Lee, D.
    Rha, J.
    Ha, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S323 - S323
  • [7] The clinical usefulness of Tc-99m ECD brain spect in measles encephalitis
    Lim, ST
    Sohn, MH
    Kim, JC
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1157 - 1157
  • [8] Statistical parametric mapping demonstrates asymmetric uptake with Tc-99m ECD and Tc-99m HMPAO SPECT in normal brain
    Brinkmann, Benjamin H.
    Jones, David T.
    Stead, Matt
    Kazemi, Noojan
    O'Brien, Terence J.
    So, Elson L.
    Blumenfeld, Hal
    Mullan, Brian P.
    Worrell, Gregory A.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2012, 32 (01): : 190 - 198
  • [9] Discrepancy between Tc-99m HMPAO SPECT and Tc-99m ECD SPECT in Creutzfeldt-Jacob disease
    Sunada, I
    Ishida, T
    Sakamoto, S
    Tsuyuguchi, N
    JOURNAL OF CLINICAL NEUROSCIENCE, 2004, 11 (06) : 648 - 650
  • [10] Discrepancies in brain perfusion SPECT findings between Tc-99m HMPAO and Tc-99m ECD: Evaluation using dynamic SPECT in patients with hyperemia
    Miyazawa, N
    Koizumi, K
    Mitsuka, S
    Nukui, H
    CLINICAL NUCLEAR MEDICINE, 1998, 23 (10) : 686 - 690