Investigation of RF spiral surface coils for NMR spectroscopy

被引:2
|
作者
Eroglu, S [1 ]
Grant, SC [1 ]
Friedman, G [1 ]
Magin, RL [1 ]
机构
[1] Univ Illinois, Dept Bioengn, Sci & Engn Off, Chicago, IL 60607 USA
关键词
D O I
10.1109/MMB.2000.893749
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Although used extensively in magnetic resonance imaging, radio frequency (RF), surface coils have not been applied widely to high-resolution spectroscopy. Inherent sensitivity limitations and potential field distortions primarily have hampered their utility. However, surface coils do offer several benefits that could prove useful in NMR spectroscopy. Easy to construct through the use of photolithography, these coils can be scaled and configured to the samples under investigation, especially cultured cells and other ex vivo biological samples. Surface coils also can be arrayed to improve coverage areas and signal-to-noise ratios (SNR). However, in designing microcoils, optimization of the geometrical parameters by talking the eddy current losses into account has considerable importance and can substentialy improve SNR. In this paper, we develop an semi-analytical model to estimate the losses for the spiral geometry that is valid for wide range of geometrical parameters.
引用
收藏
页码:92 / 96
页数:5
相关论文
共 50 条
  • [1] Evaluation of the turn variation of spiral RF surface coils for MR microscopic imaging and spectroscopy
    Woo, D.
    Choe, B.
    Ha, S.
    MEDICAL PHYSICS, 2006, 33 (06) : 2011 - 2011
  • [2] Evaluation of the turn variation of spiral RF surface coils for MR microscopic imaging and spectroscopy
    Woo, Dong-Cheol
    Choe, Bo-Young
    Ha, Seung-Hoon
    Choi, Chi-Bong
    MEASUREMENT, 2007, 40 (06) : 615 - 622
  • [3] FEATURES OF SURFACE BOILING IN SPIRAL COILS
    BREUS, VI
    BELYAKOV, II
    SOVIET ATOMIC ENERGY, 1990, 68 (06): : 526 - 529
  • [4] SIMPLE RF MATCHING FOR NMR COILS IN ENDOR SPECTROMETERS
    PERIC, M
    DULCIC, A
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1981, 14 (06): : 700 - 701
  • [5] Nested Surface Coils for Multinuclear NMR
    Magill A.W.
    Gruetter R.
    eMagRes, 2011, 2011
  • [6] Litz wire RF coils for low frequency NMR applications
    Giovannetti, Giulio
    Menichetti, Luca
    MEASUREMENT, 2017, 110 : 116 - 120
  • [7] Error-tolerant RF litz coils for NMR/MRI
    Doty, FD
    Entzminger, G
    Hauck, CD
    JOURNAL OF MAGNETIC RESONANCE, 1999, 140 (01) : 17 - 31
  • [8] Microfabrication of Helmholtz coils with integrated channels for NMR spectroscopy
    Ehrmann, K
    Saillen, M
    Vincent, F
    Massin, C
    Besse, PA
    Popovic, RS
    MEMS 2006: 19TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2006, : 366 - 369
  • [9] HTS insert coils for high field NMR spectroscopy
    Hazelton, DW
    Yuan, X
    Weijers, HW
    Van Sciver, SW
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 956 - 959
  • [10] NMR spiral surface microcoils: Applications
    Gimi, B
    Eroglu, S
    Leoni, L
    Desai, TA
    Magin, RL
    Roman, BB
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2003, 18B (01) : 1 - 8