Validity of the Nintendo Wii Balance Board for Kinetic Gait Analysis

被引:12
|
作者
Eguchi, Ryo [1 ]
Takahashi, Masaki [2 ]
机构
[1] Keio Univ, Grad Sch Sci & Technol, Sch Sci Open & Environm Syst, Kohoku Ku, 3-14-1 Hiyoshi, Yokohama, Kanagawa 2238522, Japan
[2] Keio Univ, Dept Syst Design Engn, Kohoku Ku, 3-14-1 Hiyoshi, Yokohama, Kanagawa 2238522, Japan
来源
APPLIED SCIENCES-BASEL | 2018年 / 8卷 / 02期
关键词
Wii Balance Board; force plate; gait; ground reaction force; center of pressure; curved walking; iterative closest point algorithm; WEIGHT-BEARING ASYMMETRY; PARKINSONS-DISEASE; PRESSURE MEASURES; STANDING BALANCE; CURVED WALKING; FORCE; RELIABILITY; SYSTEM; ADULTS; TASKS;
D O I
10.3390/app8020285
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The Nintendo Wii Balance Board (WBB) has been suggested as an inexpensive, portable and accessible alternative to costly laboratory-grade force plates for measuring the vertical ground reaction force (vGRF) and center of pressure (COP). Kinetic gait analysis provides important information for the rehabilitation of patients with gait disorders; however, the validity of the WBB for measuring kinetic gait parameters has not been evaluated. Therefore, the purpose of this study is to determine the accuracy of walking force measurementswhich change dynamically in a short period of stance timecollected with the WBB. Three healthy adults were asked to walk 10 steps along both straight and curved paths in clockwise (CW) and counterclockwise (CCW) directions while measurements were taken using the WBB and the force plate. The accuracy of the vGRF, COP trajectory, and stance duration were evaluated using the root-mean-square error (RMSE), Pearson's correlation coefficient and Bland-Altman plots (BAPs) to compare the WBB and the force plate. The results of the vGRF showed high accuracy (r > 0.96 and %RMSE < 6.1% in the mean values), and the stance duration as defined by the vGRF and COP trajectory was equivalent to that of commercial instrumented insoles, which are used as an alternative to the force plates. From these results, we determined that the WBB may be used for kinetic gait analysis in clinical settings where lower accuracy is acceptable.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Validity and reliability of the Nintendo Wii Balance Board for assessment of standing balance
    Clark, Ross A.
    Bryant, Adam L.
    Pua, Yonghao
    McCrory, Paul
    Bennell, Kim
    Hunt, Michael
    GAIT & POSTURE, 2010, 31 (03) : 307 - 310
  • [2] Nintendo Wii Balance Board for Balance Disorders
    Gil-Gomez, Jose-Antonio
    Lozano, Jose-Antonio
    Alcaniz, Mariano
    Albiol Perez, Sergio
    2009 VIRTUAL REHABILITATION INTERNATIONAL CONFERENCE, 2009, : 213 - 213
  • [3] Can the Nintendo WII Balance Board be Used for a Reliable Assessment of the Initiation of Gait?
    Verdini, Federica
    Tigrini, Andrea
    Fioretti, Sandro
    Mengarelli, Alessandro
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [4] Validity of the Nintendo Wii Balance Board for the Assessment of Balance Measures in the Functional Reach Test
    Mengarelli, Alessandro
    Cardarelli, Stefano
    Strazza, Annachiara
    Di Nardo, Francesco
    Fioretti, Sandro
    Verdini, Federica
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2018, 26 (07) : 1400 - 1406
  • [5] Validity of the Nintendo Wii® balance board for the assessment of standing balance in Parkinson's disease
    Holmes, Jeffrey D.
    Jenkins, Mary E.
    Johnson, Andrew M.
    Hunt, Michael A.
    Clark, Ross A.
    CLINICAL REHABILITATION, 2013, 27 (04) : 361 - 366
  • [6] Validity and reliability of balance assessment software using the Nintendo Wii balance board: usability and validation
    Park, Dae-Sung
    Lee, GyuChang
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
  • [7] Validity and reliability of balance assessment software using the Nintendo Wii balance board: usability and validation
    Dae-Sung Park
    GyuChang Lee
    Journal of NeuroEngineering and Rehabilitation, 11
  • [8] Balance Evaluation in Hemophilic Patients by Nintendo Wii Balance Board
    Perez-Alenda, S.
    Carrasco, J. J.
    Casana-Granell, J.
    Alakhdar-Mohamara, Y.
    Cuesta-Barriuso, R.
    Torres-Ortuno, A.
    Cruz-Montecinos, C.
    Querol, F.
    HAEMOPHILIA, 2015, 21 (06) : E548 - E549
  • [9] Validation of the Nintendo Wii Balance Board for stabilometry measurements
    Nagymate, Gergely
    Vamos, Bence
    Kiss, Rita M.
    2016 INTERNATIONAL SYMPOSIUM ON SMALL-SCALE INTELLIGENT MANUFACTURING SYSTEMS (SIMS), 2016, : 111 - 114
  • [10] Validity and Reliability of the Nintendo Wii in Measuring Standing Balance
    Field-Eaton, Sean D.
    Orloff, Heidi A.
    Nakamura, Bryson H.
    Olesh, Erienne V.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 529 - 529