Bone modifications around porous trabecular implants inserted with or without primary stability 2 months after tooth extraction: A 3-year controlled trial

被引:0
|
作者
Bianconi, Stefano [1 ,2 ]
Wang, Horn-Lay [3 ]
Testori, Tiziano [3 ,4 ,5 ]
Fontanella, Fabrizio [2 ]
Del Fabbro, Massimo [4 ,5 ]
机构
[1] Univ Sacro Cuore, Rome, Italy
[2] Gen Hosp, Dept Oral Surg & Dent, Bolzano, Italy
[3] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
[4] Univ Milan, Dept Biomed Surg & Dent Sci, Milan, Italy
[5] IRCCS Orthopaed Inst Galeazzi, Dent Clin, Milan, Italy
关键词
alveolar bone resorption; bone regeneration; dental implants; implant primary stability; osseoincorporation; osseointegration; osseous defects; RESONANCE FREQUENCY-ANALYSIS; DENTAL IMPLANTS; AESTHETIC ZONE; PLACEMENT; IMMEDIATE; OSSEOINTEGRATION; TITANIUM; SOCKETS; TANTALUM; REGENERATION;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Implant primary stability has long been considered a prerequisite for successful osseointegration. However, achieving stability may be difficult when placing implants in wide postextractive bone defects. The purpose of this study was to conduct a clinical and radiographic investigation of bone modifications at porous-structured implants inserted with or without primary stability. Materials and methods: Fifty porous-structured implants were inserted in the posterior sockets of 50 consecutive patients 2 months after tooth extraction, combined with allogeneic bone and a resorbable membrane. The implants were divided into two groups according to insertion torque: spinner (spinning at 35 Ncm, n = 23) and stable (stable at 35 Ncm, n = 27). Implant stability was assessed by resonance frequency analysis from baseline to 6-month function. Follow-up took place 3 years after implant placement. Results: At baseline, the implant stability quotient was undetectable in the spinner group and averaged 75.07 +/- 5.84 in the stable group. At uncovering, the implant stability quotient increased to 71.33 +/- 4.42 and 77.97 +/- 3.30 in the spinner and stable group, respectively (P < 0.001). After 6 months of loading, no between-group difference in implant stability quotient was found (P = 0.13). Marginal bone level changes were similar between groups at all follow-ups, averaging -0.41 +/- 0.77 mm and -0.15 +/- 0.53 mm at 36-month follow-up in the spinner and stable group, respectively (P = 0.35). No implant failed throughout the observation period. Neither biological nor mechanical complications occurred. Conclusion: Implants with a moderately rough surface and a porous-structured body may osseointegrate even without primary stability.
引用
收藏
页码:241 / 252
页数:12
相关论文
共 6 条
  • [1] Immediate Postextractive Implants With and Without Bone Graft: 3-year Follow-up Results From a Multicenter Controlled Randomized Trial
    Mastrangelo, Filiberto
    Gastaldi, Giorgio
    Vinci, Raffaele
    Troiano, Giuseppe
    Tettamanti, Lucia
    Gherlone, Enrico
    Lo Muzio, Lorenzo
    IMPLANT DENTISTRY, 2018, 27 (06) : 638 - 645
  • [2] Bone Response and Soft Tissue Changes Around Implants With/Without Abutments Supporting Fixed Partial Dentures: Results From a 3-Year, Prospective, Randomized, Controlled Study
    Gothberg, Catharina
    Andre, Ulrika
    Grondahl, Kerstin
    Thomsen, Peter
    Slotte, Christer
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (02) : 309 - 322
  • [3] Extra oral digital scanning and imaging superimposition for volume analysis of bone remodeling after tooth extraction with and without 2 types of particulate porcine mineral insertion: A randomized controlled trial
    Barone, Antonio
    Toti, Paolo
    Menchini-Fabris, Giovan-Battista
    Derchi, Giacomo
    Marconcini, Simone
    Covani, Ugo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (04) : 750 - 759
  • [4] A 3-year prospective randomized clinical trial of alveolar bone crest response and clinical parameters through 1, 2, and 3 years of clinical function of implants placed 4 months after alveolar ridge preservation using two different allogeneic bone-grafting materials
    Önder Solakoğlu
    Duygu Ofluoğlu
    Heidi Schwarzenbach
    Guido Heydecke
    Daniel Reißmann
    Sertan Ergun
    Werner Götz
    International Journal of Implant Dentistry, 8
  • [5] A 3-year prospective randomized clinical trial of alveolar bone crest response and clinical parameters through 1, 2, and 3 years of clinical function of implants placed 4 months after alveolar ridge preservation using two different allogeneic bone-grafting materials
    Solakoglu, Onder
    Ofluoglu, Duygu
    Schwarzenbach, Heidi
    Heydecke, Guido
    Reissmann, Daniel
    Ergun, Sertan
    Goetz, Werner
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2022, 8 (01)
  • [6] A randomized-controlled clinical trial evaluating clinical and radiological outcomes after 3 and 5 years of dental implants placed in bone regenerated by means of GBR techniques with or without the addition of BMP-2
    Jung, Ronald E.
    Windisch, Simone I.
    Eggenschwiler, Ariane M.
    Thoma, Daniel S.
    Weber, Franz E.
    Haemmerle, Christoph H. F.
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (07) : 660 - 666