Absolute energy calibration of the Telescope Array fluorescence detector with an electron linear accelerator

被引:1
|
作者
Shibata, T. [1 ]
Beitollahi, M.
Fukushima, M. [1 ]
Ikeda, D. [1 ]
Langely, K.
Matthews, J. N.
Sagawa, H. [1 ]
Shin, B. K.
Thomas, S. B.
Thomson, G. B. [1 ]
机构
[1] Univ Tokyo, ICRR, Kashiwa, Chiba 2778582, Japan
关键词
SPECTRUM; END;
D O I
10.1051/epjconf/20135310004
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The Electron Light Source(ELS) is a new light source for the absolute energy calibration of cosmic ray Fluorescence Detector(FD) telescopes. The ELS is a compact electron linear accelerator with a typical output of 109 electrons per pulse at 40 MeV. We fire the electron beam vertically into the air 100 m in front of the telescope. The electron beam excites the gases of the atmosphere in the same way as the charged particles of the cosmic ray induced extensive air shower. The gases give off the same light with the same wavelength dependence. The light passes through a small amount of atmosphere and is collected by the same mirror and camera with their wavelength dependence. In this way we can use the electron beam from ELS to make an end-to-end calibration of the telescope. In September 2010, we began operation of the ELS and the FD telescopes observed the fluorescence photons from the air shower which was generated by the electron beam. In this article, we will reort the status of analysis of the absolute energy calibration with data which was taken in September 2010, and beam monitor study in November 2011.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Absolute energy calibration of FD by an electron linear accelerator for Telescope Array
    Shibata, T.
    Enomoto, A.
    Fukuda, S.
    Fukushima, M.
    Furukawa, K.
    Ikeda, D.
    Ikeda, M.
    Iwase, H.
    Kakihara, K.
    Kamitani, T.
    Kondo, Y.
    Matthews, J. N.
    Ogio, S.
    Ohsawa, S.
    Sagawa, H.
    Sanami, T.
    Satoh, M.
    Shidara, T.
    Sugimura, T.
    Yoshida, M.
    INTERNATIONAL SYMPOSIUM ON THE RECENT PROGRESS OF ULTRA-HIGH ENERGY COSMIC RAY OBSERVATION, 2011, 1367 : 44 - 49
  • [2] Calibration of the telescope array air Fluorescence Detector
    Tokuno, H.
    Fukushima, M.
    Kadota, K.
    Kakimoto, F.
    Kawana, S.
    Machida, S.
    Matthews, J. N.
    Murano, Y.
    Ogio, S.
    Sagawa, H.
    Sakurai, N.
    Shibata, T.
    Shimodaira, H.
    Takeda, M.
    Taketa, A.
    Takita, M.
    Tameda, Y.
    Tanaka, M.
    Thomas, S. B.
    Udo, S.
    Wiencke, L. R.
    Yoshida, S.
    Proceedings of the 29th International Cosmic Ray Conference Vol 8: HE 1.5, 2005, : 221 - 224
  • [3] End-to-end absolute energy calibration of atmospheric fluorescence telescopes by an electron linear accelerator
    Shibata, T.
    Enomoto, A.
    Fukuda, S.
    Fukushima, M.
    Furukawa, K.
    Ikeda, D.
    Ikeda, M.
    Kakihara, K.
    Ohsawa, S.
    Sagawa, H.
    Satoh, M.
    Shidara, T.
    Sugimura, T.
    Yoshida, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 597 (01): : 61 - 66
  • [4] Telescope Array; Progress of fluorescence detector
    Ogio, S.
    Fukushima, M.
    Kakimoto, F.
    Chikawa, M.
    Proceedings of the 29th International Cosmic Ray Conference Vol 8: HE 1.5, 2005, : 173 - 176
  • [5] Novel Amorphous Silicon Detector Array for Linear Accelerator Electron Measurements
    Shaikh, M.
    Burmeister, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E248 - E248
  • [6] Absolute calibration of the infrared array camera on the Spitzer Space Telescope
    Reach, WT
    Megeath, ST
    Cohen, M
    Hora, J
    Carey, S
    Surace, J
    Willner, SP
    Barmby, P
    Wilson, G
    Glaccum, W
    Lowrance, P
    Marengo, M
    Fazio, GG
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2005, 117 (835) : 978 - 990
  • [7] Recent results of the energy spectrum and mass composition from Telescope Array Fluorescence Detector
    Ikeda, Daisuke
    23RD EUROPEAN COSMIC RAY SYMPOSIUM (AND 32ND RUSSIAN COSMIC RAY CONFERENCE), 2013, 409
  • [8] Calibration of photomultiplier tubes for the fluorescence detector of telescope array experiment using a Rayleigh scattered laser beam
    Kawana, Shingo
    Sakurai, Nobuyuki
    Fujii, Toshihiro
    Fukushima, Masaki
    Inoue, Naoya
    Matthews, John N.
    Ogio, Shoichi
    Sagawa, Hiroyuki
    Taketa, Akimichi
    Takita, Masato
    Thomas, Stan B.
    Tokuno, Hisao
    Tsunesada, Yoshiki
    Udo, Shigeharu
    Wiencke, Lawrence R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 681 : 68 - 77
  • [9] The Telescope Array Middle Drum fluorescence detector simulation on GPUs
    Abu-Zayyad, Tareq
    20TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP2013), PARTS 1-6, 2014, 513
  • [10] On site calibration for new fluorescence detectors of the telescope array experiment
    Tokuno, H.
    Murano, Y.
    Kawana, S.
    Tameda, Y.
    Taketa, A.
    Ikeda, D.
    Udo, S.
    Ogio, S.
    Fukushima, M.
    Azuma, R.
    Fukuda, M.
    Inoue, N.
    Kadota, K.
    Kakimoto, F.
    Sagawa, H.
    Sakurai, N.
    Shibata, T.
    Takeda, M.
    Tsunesada, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 601 (03): : 364 - 371