Nanostructured voltammetric sensor for ultra-trace anabolic drug determination in food safety field

被引:14
|
作者
Regiart, Matias [1 ]
Pereira, Sirley V. [1 ]
Spotorno, Viviana G. [2 ]
Bertolino, Franco A. [1 ]
Raba, Julio [1 ]
机构
[1] Univ Nacl San Luis, CONICET, Dept Quim, INQUISAL, San Luis, Argentina
[2] INTA, Inst Nacl Tecnol Agr, CIRN, IRB,Inst Recursos Biol, Buenos Aires, DF, Argentina
关键词
Voltammetric sensor; Nanostructured platform; Anabolic drug; Food safety; BETA-ADRENERGIC AGONISTS; LIQUID-CHROMATOGRAPHY; CARBON NANOTUBES; MICROFLUIDIC IMMUNOSENSOR; RAPID-DETERMINATION; BOVINE HAIR; HUMAN URINE; ILLEGAL USE; CLENBUTEROL; BIOSENSOR;
D O I
10.1016/j.snb.2013.07.117
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive electrochemical sensor for clenbuterol (CL) determination in bovine urine samples was designed. This drug was originally developed for the treatment of respiratory pathologies. However, in the livestock industry, CL has been used as growth promoter because it stimulates the muscle growth and lipid degradation. The drug residues accumulated in animal tissues represent a potential risk for the human health. Subsequently, the development of a fast and simple method for the CL quantification employed to detect its abuse in livestock production is an attractive analytical challenge. The proposed method was based on the use of a screen printed carbon electrode (SPCE) modified with multiwall carbon nanotubes (MWCNTs) in a matrix of chitosan (CH) on gold nanoparticles (AuNPs) previously incorporated by electrodeposition process. The MWCNTs-CH/AuNPs/SPCE was characterized by cyclic voltammetry, X-ray diffraction and scan electron microscopy. With the aim to carry out the CL determination, a pre-concentration procedure was required. For this purpose, we employed anti-CL antibodies immobilized on magnetic microparticles (MPs) as bioaffinity support to capture the drug present in the sample. This support was exposed to a desorption process. Later, the electrochemical detection by square wave voltammetry (OSWV) was performed. The sensor exhibited excellent performances with a linear response range in concentrations from 0.01 to 6 ng mL(-1). The detection and quantification limits obtained were 0.003 and 0.01 ng mL(-1), respectively with an analysis time of 19 min and a R. S. D. below 5.8%. As a conclusion, we can claim that the results obtained by the proposed sensor were successful. (C) 2013 Elsevier B. V. All rights reserved.
引用
收藏
页码:1241 / 1249
页数:9
相关论文
共 50 条
  • [1] Voltammetric determination of ultra-trace total mercury and toxic metals in meals
    Locatelli, Clinio
    Melucci, Dora
    FOOD CHEMISTRY, 2012, 130 (02) : 460 - 466
  • [2] Development simple and sensitive voltammetric procedure for ultra-trace determination of U(VI)
    Tyszczuk-Rotko, Katarzyna
    Domanska, Katarzyna
    Czech, Bozena
    Rotko, Marek
    TALANTA, 2017, 165 : 474 - 481
  • [3] Gold Nanoparticles/Biphenol-biphenoquinone for Ultra-trace Voltammetric Determination of Captopril
    Shahbakhsh, M.
    Hashemzaei, Z.
    Narouie, S.
    Shahbakhsh, Y.
    Noroozifar, M.
    ELECTROANALYSIS, 2021, 33 (03) : 713 - 722
  • [4] Highly Sensitive Adsorptive Stripping Voltammetric Method for the Ultra-trace Determination of Chromium(VI)
    Ravin Jugade
    Arun P. Joshi
    Analytical Sciences, 2006, 22 : 571 - 574
  • [5] Highly sensitive adsorptive stripping voltammetric method for the ultra-trace determination of chromium(VI)
    Jugade, R
    Joshi, AP
    ANALYTICAL SCIENCES, 2006, 22 (04) : 571 - 574
  • [6] Improvement of the ultra-trace voltammetric determination of Rh in environmental samples using signal transformation
    Almecija, C.
    Cobelo-Garcia, A.
    Santos-Echeandia, J.
    TALANTA, 2016, 146 : 737 - 743
  • [7] Rapid ultra-trace determination of Fukushima-derived radionuclides in food
    Weller, Anica
    Hori, Mayumi
    Shozugawa, Katsumi
    Steinhauser, Georg
    FOOD CONTROL, 2018, 85 : 376 - 384
  • [8] Fabrication of an Extra Sensitive Voltammetric Sensor Using Nanoparticles of Molecularly Imprinted Polymer for Determination of Ultra-Trace Promethazine in Plasma Sample
    Alizadeh, Taher
    Ganjali, Mohammad Reza
    Akhoundian, Maedeh
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 10427 - 10441
  • [9] Ultra-trace electrolytic moisture sensor.
    Zhang, YN
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 212 : 67 - IEC
  • [10] Voltammetric ultra trace determination of tellurium
    Sharma, Pradeep
    Agarwal, Anupama
    ANALYTICAL LETTERS, 2006, 39 (07) : 1421 - 1427