Full-scale experimental study of the seismic performance of pretensioned spun high-strength concrete piles

被引:13
|
作者
Ren, Junwei [1 ]
Xu, Quanbiao [2 ,3 ]
Chen, Gang [2 ,3 ]
Yu, Xiaodong [4 ]
Gong, Shunfeng [1 ]
Lu, Yong [5 ]
机构
[1] Zhejiang Univ, Dept Civil Engn, Hangzhou 310058, Peoples R China
[2] Zhejiang Univ Co Ltd, Architectural Design & Res Inst, Hangzhou 310028, Peoples R China
[3] Zhejiang Univ, Res Ctr Balance Architecture, Hangzhou 310028, Peoples R China
[4] Ningbo Yizhong Concrete Pile Co Ltd, Ningbo 315450, Peoples R China
[5] Univ Edinburgh, Sch Engn, Inst Infrastruct & Environm, Edinburgh EH9 3JL, Midlothian, Scotland
基金
中国国家自然科学基金;
关键词
Pretensioned spun concrete pile; Seismic performance; Cyclic loading test; Axial force ratio; Lateral bearing capacity; Ductility; FINITE-ELEMENT-ANALYSIS; BEHAVIOR; PRECAST; DESIGN; COMPRESSION; DAMAGE;
D O I
10.1016/j.soildyn.2022.107467
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Pretensioned spun high-strength concrete (PHC) piles have been widely used in the pile foundations of buildings in soft soil areas due to their high axial bearing capacity and good economic benefit. However, the behavior of PHC piles under lateral loading is generally poor and this restricts their application in high-intensity seismic regions, especially for high-rise buildings. The existing research on the performance of PHC piles under cyclic lateral loading and with the presence of axial force is scarce. In this paper, the seismic performance of PHC piles is systematically evaluated through full-scale tests and numerical simulations. Lateral cyclic loading tests for two full-scale PHC pile specimens were conducted under different axial force ratios, and their performances were examined in terms of cracking pattern, failure mode, hysteretic characteristics, lateral bearing capacity, ductility, stiffness degradation and energy dissipation capacity. A dedicated finite element (FE) model was then developed using the software DIANA to compute the cyclic behavior of PHC piles, and the model was verified against the experimental results. Using the verified FE model, parametric analyses have been carried out to study the effects of axial force ratio, prestressing level of prestressing tendons, longitudinal reinforcement ratio, concrete wall thickness of the pile body and distributed pattern of prestressing tendons on the seismic performance of the PHC piles. The results show that the axial force ratio has a significant effect on the cyclic behavior and failure mode of PHC piles; an increase in the axial force ratio leads to an increase in the lateral bearing capacity but generally a decrease in the deformation capacity. The failure mode of the PHC piles is controlled by the rupture of prestressing tendons under lower axial force ratios (less than 0.15) but crushing of concrete under higher axial force ratios (greater than 0.15). Increasing the concrete wall thickness tends to improve the overall performance of the PHC piles, especially under higher axial force ratios.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Full-Scale Testing of Pretensioned High-Strength Concrete Girders with Debonded Strands
    Kim, Jae-Ki
    Shin, Hyun-Oh
    Shin, Hyun-Yang
    Yoon, Young-Soo
    [J]. JOURNAL OF BRIDGE ENGINEERING, 2011, 16 (06) : 847 - 853
  • [2] Experimental studies on full-scale high-strength concrete columns
    Xiao, Y
    Yun, HW
    [J]. ACI STRUCTURAL JOURNAL, 2002, 99 (02) : 199 - 207
  • [3] Seismic performance of pretensioned centrifugal spun concrete piles with steel strands
    Ren, Junwei
    Xu, Quanbiao
    Chen, Gang
    Yu, Xiaodong
    Gong, Shunfeng
    Lu, Yong
    [J]. STRUCTURES, 2023, 50 : 1303 - 1319
  • [4] DURABILITY OF PRETENSIONED SPUN CONCRETE PILES USING HIGH PERFORMANCE CONCRETE
    Tran Van Mien
    Pham Quoc Thuan
    Nguyen Minh Tu
    Tran Trong Tri
    [J]. ADVANCES IN CONCRETE STRUCTURAL DURABILITY: PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON DURABILITY OF CONCRETE STRUCTURES ICDCS2010, 2010, : 681 - 688
  • [5] Repair and performance of a full-scale pretensioned concrete girder
    Saiidi, MS
    Labia, Y
    Douglas, B
    [J]. PCI JOURNAL, 2000, 45 (02): : 96 - +
  • [6] Collapse of a high-rise building with pretensioned high-strength concrete piles
    Wang, Wei-Dong
    Li, Qing
    Hu, Yun
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-FORENSIC ENGINEERING, 2020, 173 (01) : 3 - 12
  • [7] Experimental Study on Axial Compression Performance of Full-scale Square Columns of Reinforced Concrete Confined by High-strength Reinforcement Hoops
    Li, Zhenbao
    Wang, Wenjing
    Zhang, Weijing
    Shao, Yunda
    Zhang, Bing
    Fan, Meiguang
    Lin, Shuangping
    [J]. TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 981 - +
  • [8] Seismic behavior of full-scale square high-strength RACFST columns
    Dong, Hongying
    Qin, Jia
    Chen, Zheng
    Cao, Wanlin
    Tang, Yunpeng
    [J]. STRUCTURES, 2021, 34 : 2600 - 2616
  • [9] Research on seismic behavior of full-scale high-strength concrete frame columns with high axial compression ratios
    Lu, Xilin
    Zhang, Guojun
    Chen, Shaolin
    [J]. Jianzhu Jiegou Xuebao/Journal of Building Structures, 2009, 30 (03): : 20 - 26
  • [10] Research on seismic behavior of full-scale high-strength concrete frame columns with high axial compression ratios
    Zhang, Guojun
    Liu, Jianxin
    Su, Qing
    Lu, Xilin
    [J]. PROCEEDINGS OF INTERNATIONAL CONFERENCE ON HEALTH MONITORING OF STRUCTURE, MATERIALS AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 657 - +