Clinical evaluation of succinylated collagen bandage lenses for ophthalmic applications

被引:7
|
作者
Hadassah, J. [1 ]
Prakash, D. [2 ]
Sehgal, P. K. [1 ]
Agarwal, A. [2 ]
Bhuvaneshwari, N. [3 ]
机构
[1] Cent Leather Res Inst, Bioprod Lab, Madras 600020, Tamil Nadu, India
[2] Dr Agarwal Eye Hosp, Res Ctr, Madras, Tamil Nadu, India
[3] Govt Royapettah Hosp, Dept Ophthalmol, Madras, Tamil Nadu, India
关键词
succinylated collagen bandage lenses; best corrected visual acuity; tear fluid levels; dissolution rate of succinylated collagen bandage lenses;
D O I
10.1159/000127833
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To study whether succinylated collagen bandage lenses (SCBL) prepared from modified bovine collagen (succinylated collagen) can replace other bandage lenses presently employed to treat various corneal conditions like filamentary keratitis, dry eyes, recurrent corneal erosions, foreign body removal and epithelial trauma. Methods: This observational case study included 32 patients (22 female and 10 male): 8 patients for filamentary keratitis (25%), 10 patients for dry eyes (31%), 4 patients for recurrent corneal erosions (13%), 7 patients for foreign body removal (22%) and 3 patients for epithelial trauma (9%). Their eyes were evaluated for biocompatibility, in vivo transparency, patient comfort, corneal fit, best corrected visual acuity (BCVA), tear fluid level and dissolution rate of SCBL. This was carried out over a 24- hour period of time. Results: SCBL exhibited good transparency and remained transparent throughout the period of study (between 0 and 24 h) in the eyes of patients. SCBL did not cause any irritation, discomfort and foreign body sensation in the eye and eyes remained comfortable throughout the experiment. BCVA in the control group of patients was 1.00 (20/20). Mean (+/- SD) BCVA before inserting SCBL (in decimal equivalent) was 0.31 (20/60) +/- 0.18 (range 0.1-0.66). BCVA (+/- SD) changed to 0.25 (20/80) +/- 0.18 4 h after the application of SCBL and 0.27 (20/70) +/- 0.18 24 h after the application of SCBL, with a safety index of 1.20. The mean (8 SD) tear fluid level before application of SCBL was 11.9 +/- 5.39 h (range 3-24 mm) and changed to 13.9 +/- 5.68 h (range 5-28 mm) after 4 h of application of SCBL and 15.9 +/- 5.72 h (range 7-30 mm) after 24 h with a safety index of 13 mm. The mean (8 SD) dissolution rate of SCBL in the control group of patients was 17.8 +/- 8.65 h (range 10-24 h) and the mean (8 SD) dissolution rate in the experimental group was 22.2 +/- 9.29 h (range 10-24 h). We report the use of SCBL in various corneal conditions. Conclusion: The present study showed that SCBL has complete corneal fit and good comfort in human eyes. Transparency was maintained for a longer period along with fair visual acuity and improvement in tear fluid levels. The disadvantages of other bandage lenses presently used to treat various corneal conditions could be overcome by the use of SCBL lenses. Copyright (C) 2008 S. Karger AG, Basel.
引用
收藏
页码:257 / 266
页数:10
相关论文
共 50 条
  • [1] Evaluation of Succinylated Collagen Bandage Lenses in Corneal Healing by the Expression of Matrix Metalloproteinases (MMP-2 and MMP-9) in Tear Fluid
    Hadassah, J.
    Bhuvaneshwari, Namita
    Rao, Urmila
    Sehgal, P. K.
    OPHTHALMIC RESEARCH, 2009, 42 (02) : 64 - 72
  • [2] Liquid crystals for ophthalmic lenses and biosensing applications
    Lin, Yi-Hsin
    Chen, Hung-Shan
    Chen, Ming-Syuan
    Wang, Yu-Jen
    Chang, Chia-Ming
    Digest of Technical Papers - SID International Symposium, 2014, 45 (01): : 563 - 566
  • [3] Preparation and Clinical Evaluation of Succinylated Collagen Punctal Plugs in Dry Eye Syndrome: A Pilot Study
    Hadassah, J.
    Bhuvaneshwari, Namita
    Singh, Deepti
    Sehgal, P. K.
    OPHTHALMIC RESEARCH, 2010, 43 (04) : 185 - 192
  • [4] The Jones compression bandage - Review and clinical applications
    Yu, GV
    Schubert, EK
    Khoury, WE
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2002, 92 (04) : 221 - 231
  • [5] EVALUATION OF OPHTHALMIC SPECTACLE LENSES USING THE HARTMANN TEST
    STATTON, CM
    BAUER, MD
    MEYERARENDT, JR
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1981, 58 (09): : 766 - 771
  • [6] Evaluation of error in the performance of power corrected ophthalmic lenses
    Trujillo-Schiaffino, Gerardo
    Patricia Salas-Peimbert, Didia
    Anguiano-Morales, Marcelino
    Malacara-Doblado, Daniel
    Vega-Pineda, Javier
    OPTICA APPLICATA, 2013, 43 (02) : 261 - 270
  • [8] Sulfur containing optical plastics and its ophthalmic lenses applications
    Jha, G. S.
    Seshadri, G.
    Mohan, A.
    Khandal, R. K.
    E-POLYMERS, 2008,
  • [9] CLINICAL-EXPERIENCE WITH A COLLAGEN BANDAGE LENS - PRELIMINARY-RESULTS
    MARQUARDT, R
    PILLUNAT, LE
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1988, 193 (04) : 350 - 355
  • [10] Microbiologic Examination of Bandage Contact Lenses Used after Corneal Collagen Cross-linking Treatment
    Yuksel, Erdem
    Yalcin, Nuriye Gokcen
    Kilic, Gaye
    Cubuk, Mehmet Ozgur
    Ozmen, Mehmet Cuneyt
    Altay, Aylin
    Caglar, Kayhan
    Bilgihan, Kamil
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2016, 24 (02) : 217 - 222