Hypotension after spinal anesthesia for cesarean section: how to approach the iatrogenic sympathectomy

被引:38
|
作者
Massoth, Christina [1 ]
Topel, Lisa [2 ]
Wenk, Manuel [2 ]
机构
[1] Univ Hosp Munster, Dept Anesthesiol Intens Care & Pain Med, Munster, Germany
[2] Florence Nightingale Hosp Dusseldorf, Dept Anesthesiol Intens Care & Pain Med, Kreuzbergstr 79, D-40489 Dusseldorf, Germany
关键词
cesarean section; fluid therapy; hypotension; spinal anesthesia; vasopressors; LATERAL TABLE TILT; ACID-BASE STATUS; PHENYLEPHRINE INFUSION; BLOOD-PRESSURE; EPHEDRINE; DELIVERY; MANAGEMENT; VASOPRESSORS; PREVENTION; NOREPINEPHRINE;
D O I
10.1097/ACO.0000000000000848
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose of review Hypotension during cesarean section remains a frequent complication of spinal anesthesia and is associated with adverse maternal and fetal events. Recent findings Despite ongoing research, no single measure for sufficient treatment of spinal-induced hypotension was identified so far. Current literature discusses the efficacy of low-dose spinal anesthesia, timing and solutions for adequate fluid therapy and various vasopressor regimens. Present guidelines favor the use of phenylephrine over ephedrine because of decreased umbilical cord pH values, while norepinephrine is discussed as a probable superior alternative with regard to maternal bradycardia, although supporting data is limited. Alternative pharmacological approaches, such as 5HT3-receptor antagonists and physical methods may be taken into consideration to further improve hemodynamic stability. Current evidence favors a combined approach of low-dose spinal anesthesia, adequate fluid therapy and vasopressor support to address maternal spinal-induced hypotension. As none of the available vasopressors is associated with relevantly impaired maternal and fetal outcomes, none of them should be abandoned from obstetric practice. Rapid crystalloid co-loading is of equivalent efficacy as compared with colloids and should be preferred because of a more favorable risk profile.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 50 条
  • [1] The effect of posture on hypotension after spinal anesthesia for cesarean section
    Levin, A
    Datta, S
    Segal, S
    [J]. ANESTHESIOLOGY, 1998,
  • [2] Hypotension after Spinal Anesthesia for Cesarean Section: Norepinephrine or Phenylephrine?
    Ruchalla, Elke
    [J]. ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 2018, 53 (05):
  • [3] Vasopressors for hypotension in spinal anesthesia for cesarean section
    Biava, Anna Maria
    Cipriani, Gianni
    Malja, Endrit
    Bilotta, Federico
    [J]. JOURNAL OF ANESTHESIA, 2024, : 155 - 156
  • [4] MANAGEMENT OF HYPOTENSION FOLLOWING SPINAL ANESTHESIA FOR CESAREAN SECTION
    LABARTINO, L
    MOJDEHI, E
    MAURO, AL
    [J]. ANESTHESIA AND ANALGESIA CURRENT RESEARCHES, 1966, 45 (02): : 179 - +
  • [5] Risk factors of more severe hypotension after spinal anesthesia for cesarean section
    Li, Yi-Shiuan
    Lin, Shih-Pin
    Horng, Huann-Cheng
    Tsai, Shiang-Wei
    Chang, Wen-Kuei
    [J]. JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2024, 87 (04) : 442 - 447
  • [6] HYPOTENSION ASSOCIATED WITH SPINAL-ANESTHESIA FOR CESAREAN-SECTION
    ROCKE, DA
    ROUT, CC
    [J]. SOUTH AFRICAN MEDICAL JOURNAL, 1993, 83 (07): : 540 - 540
  • [7] Role of pleth variability index for predicting hypotension after spinal anesthesia for cesarean section
    Sun, S.
    Huang, S. Q.
    [J]. INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2014, 23 (04) : 324 - 329
  • [8] HYPOTENSION AFTER SPINAL ANESTHESIA FOR CESAREAN SECTION: IDENTIFICATION OF RISK FACTORS USING AN ANESTHESIA INFORMATION MANAGEMENT SYSTEM
    Brenck, F.
    Hartmann, B.
    Katzer, C.
    Obaid, R.
    Brueggmann, D.
    Benson, M.
    Roehrig, R.
    Junger, A.
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2009, 23 (02) : 85 - 92
  • [9] Hypotension after spinal anesthesia for cesarean section: identification of risk factors using an anesthesia information management system
    F. Brenck
    B. Hartmann
    C. Katzer
    R. Obaid
    D. Brüggmann
    M. Benson
    R. Röhrig
    A. Junger
    [J]. Journal of Clinical Monitoring and Computing, 2009, 23
  • [10] Preloading vs. postloading of colloid for the prevention of hypotension after spinal anesthesia for cesarean section
    Brummel, C
    Mercier, F
    Fuller, A
    Mathusamy, A
    Lipman, S
    Cohen, SE
    Riley, ET
    [J]. ANESTHESIOLOGY, 2004, 100 (05) : B33 - B33