Prospective Evaluation of a Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry System in a Hospital Clinical Microbiology Laboratory for Identification of Bacteria and Yeasts: a Bench-by-Bench Study for Assessing the Impact on Time to Identification and Cost-Effectiveness

被引:245
|
作者
Tan, K. E. [1 ]
Ellis, B. C. [2 ]
Lee, R. [2 ]
Stamper, P. D. [1 ]
Zhang, S. X. [1 ,2 ]
Carroll, K. C. [1 ,2 ]
机构
[1] Johns Hopkins Univ, Sch Med, Div Med Microbiol, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ Hosp, Microbiol Lab, Baltimore, MD 21287 USA
关键词
ROUTINE IDENTIFICATION; ANAEROBIC-BACTERIA; MS;
D O I
10.1128/JCM.01405-12
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been found to be an accurate, rapid, and inexpensive method for the identification of bacteria and yeasts. Previous evaluations have compared the accuracy, time to identification, and costs of the MALDI-TOF MS method against standard identification systems or commercial panels. In this prospective study, we compared a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) to determine the performance in actual practice using a specimen-based, bench-by-bench approach. The potential impact on time to identification (TTI) and costs had MALDI-TOF MS been the first-line identification method was quantitated. The MALDI protocol includes supplementary tests, notably for Streptococcus pneumoniae and Shigella, and indications for repeat MALDI-TOF MS attempts, often not measured in previous studies. A total of 952 isolates (824 bacterial isolates and 128 yeast isolates) recovered from 2,214 specimens were assessed using the MALDI protocol. Compared with standard protocols, the MALDI protocol provided identifications 1.45 days earlier on average (P < 0.001). In our laboratory, we anticipate that the incorporation of the MALDI protocol can reduce reagent and labor costs of identification by $102,424 or 56.9% within 12 months. The model included the fixed annual costs of the MALDI-TOF MS, such as the cost of protein standards and instrument maintenance, and the annual prevalence of organisms encountered in our laboratory. This comprehensive cost analysis model can be generalized to other moderate-to high-volume laboratories.
引用
收藏
页码:3301 / 3308
页数:8
相关论文
共 50 条
  • [1] Identification of Rare Pathogenic Bacteria in a Clinical Microbiology Laboratory: Impact of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry
    Seng, Piseth
    Abat, Cedric
    Rolain, Jean Marc
    Colson, Philippe
    Lagier, Jean-Christophe
    Gouriet, Frederique
    Fournier, Pierre Edouard
    Drancourt, Michel
    La Scola, Bernard
    Raoult, Didier
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (07) : 2182 - 2194
  • [2] MATRIX-ASSISTED LASER DESORPTION IONIZATION-TIME OF FLIGHT MASS SPECTROMETRY FOR THE IDENTIFICATION OF BACTERIA AND YEASTS IN A CLINICAL MICROBIOLOGICAL LABORATORY: A REVIEW
    Steensels, D.
    Verhaegen, J.
    Lagrou, K.
    ACTA CLINICA BELGICA, 2011, 66 (04) : 267 - 273
  • [3] Evaluation of the Vitek MS Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry System for the Identification of Bacteria in Routine Clinical Microbiology
    Chheda, P.
    Mukundan, U.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2019, 21 (03): : S40 - S40
  • [4] Cost-Effectiveness of Switch to Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Routine Bacterial Identification
    Gaillot, Olivier
    Blondiaux, Nicolas
    Loiez, Caroline
    Wallet, Frederic
    Lemaitre, Nadine
    Herwegh, Stephanie
    Courcol, Rene J.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (12) : 4412 - 4412
  • [5] Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry in Clinical Microbiology
    Patel, Robin
    CLINICAL INFECTIOUS DISEASES, 2013, 57 (04) : 564 - 572
  • [6] Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for the Identification of Clinically Relevant Bacteria
    Benagli, Cinzia
    Rossi, Viviana
    Dolina, Marisa
    Tonolla, Mauro
    Petrini, Orlando
    PLOS ONE, 2011, 6 (01):
  • [7] Identification of Pasteurellaceae by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry
    Burckhardt, I.
    Gillmann, E.
    Mutters, R.
    Zimmermann, S.
    INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2012, 302 : 111 - 111
  • [8] Identification of Molds by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry
    Sanguinetti, Maurizio
    Posteraro, Brunella
    JOURNAL OF CLINICAL MICROBIOLOGY, 2017, 55 (02) : 369 - 379
  • [9] Multicenter evaluation of the VITEK MS matrix-assisted laser desorption/ionization-time of flight mass spectrometry system for identification of bacteria, including Brucella, and yeasts
    Girard, Victoria
    Monnin, Valerie
    Giraud, Delphine
    Polsinelli, Sophie
    Caille, Marion
    Procop, Gary W.
    Tuohy, Marion
    Wilson, Deborah
    Richter, Sandra S.
    Kiss, Katalin
    Clem, Kimberly
    Tolli, Nicholas
    Bridon, Laurence
    Bradford, Constance
    Blamey, Sara
    Li, Jay
    Pincus, David H.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2021, 40 (09) : 1909 - 1917
  • [10] Improved Performance of Bacterium and Yeast Identification by a Commercial Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry System in the Clinical Microbiology Laboratory
    Haigh, John
    Degun, Amarjeet
    Eydmann, Melvyn
    Millar, Michael
    Wilks, Mark
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (09) : 3441 - 3441