Using a Stack Shunt to Mitigate Catalyst Support Carbon Corrosion in Polymer Electrolyte Membrane Fuel Cell Stacks During Start-Stop Cycling

被引:10
|
作者
Bona, Denis [1 ,2 ]
Curtin, Dennis E.
Pedrazzo, Francesco [2 ]
Tresso, Elena Maria [3 ,4 ]
机构
[1] Politecn Torino, Fac Engn, Dept Elect & Telecommun, I-10129 Turin, Italy
[2] Electro Power Syst SpA, I-10144 Turin, Italy
[3] Politecn Torino, Fac Engn, Dept Appl Sci & Technol, I-10129 Turin, Italy
[4] Italy Ctr Space Human Robot Polito, Ist Italiano Tecnol, I-10129 Turin, Italy
来源
关键词
PEM fuel cell; carbon corrosion; start-stop cycles; stack shunt; voltage degradation; DURABILITY; DEGRADATION; PEMFC;
D O I
10.1115/1.4025535
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Carbon black based electrodes are generally recognized as state of the art for PEM fuel cell technology due to the high performance achieved with a relatively low Pt content. However, the catalyst carbon support is prone to carbon oxidation. This leads to a loss of the catalyst area and overall performance, along with a higher mass transport loss due to an increased flooding tendency. This phenomenon is particularly severe when the fuel cell experiences repetitive start-stop cycles. Therefore, specific countermeasures against catalyst layer carbon oxidation are required, especially for automotive and backup power applications, where the startup/shutdown rate is considerably high. The authors evaluated a basic design that uses a stack shunt. A properly modified control protocol, which includes the stack shunt, is able to avoid high cathode potential peaks, which are known to accelerate catalyst carbon support corrosion and its negative effects. During two separate durability tests, one adopting the shunt design and another using nonprotected shutdown, a 24-cell stack was subjected to continuous starts and stops for several months and its performance constantly monitored. The results show that when the shunt is used, there is a 37% reduction in the voltage degradation rate for each startup/shutdown cycle and a two-fold increase in the number of startup/shutdown cycles before an individual cell reached the specified "end of life" voltage criteria. Furthermore, ex situ FE-SEM analysis revealed cathode catalyst layer thinning, which is an indication that the emerging degradation mechanism is the catalyst support carbon corrosion, as expected. This provides further support that the constant voltage degradation rate typically experienced in PEMFCs can be primarily attributed to the catalyst support carbon corrosion rate. The proposed shunt protocol is very cost effective and does not require any substantial changes in the system. For this reason, its adoption is recommended as a viable method to decrease the catalyst support carbon corrosion rate and extend the operating life of the PEMFC stack.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Start-Stop Phenomena in Channel and Land Areas of a Polymer Electrolyte Fuel Cell
    Schneider, I. A.
    von Dahlen, S.
    ELECTROCHEMICAL AND SOLID STATE LETTERS, 2011, 14 (02) : B30 - B33
  • [2] START/STOP INDUCED CARBON CORROSION IN POLYMER ELECTROLYTE FUEL CELLS
    Linse, Nicolas
    Scherer, Guenther G.
    Wokaun, Alexander
    Gubler, Lorenz
    PROCEEDINGS OF THE ASME 8TH INTERNATIONAL CONFERENCE ON FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY 2010, VOL 2, 2010, : 357 - 362
  • [3] Start-Stop Phenomena in Channel and Land Areas of a Polymer Electrolyte Fuel Cell (PEFC)
    von Dahlen, S.
    Scherer, G. G.
    Wokaun, A.
    Schneider, I. A.
    POLYMER ELECTROLYTE FUEL CELLS 10, PTS 1 AND 2, 2010, 33 (01): : 1365 - +
  • [4] Simulated start-stop as a rapid aging tool for polymer electrolyte fuel cell electrodes
    Hartnig, Christoph
    Schmidt, Thomas J.
    JOURNAL OF POWER SOURCES, 2011, 196 (13) : 5564 - 5572
  • [5] Consistency analysis of polymer electrolyte membrane fuel cell stack during cold start
    Lin, Rui
    Zhu, Yike
    Ni, Meng
    Jiang, Zhenghua
    Lou, Diming
    Han, Lihang
    Zhong, Di
    APPLIED ENERGY, 2019, 241 : 420 - 432
  • [6] Understanding the process of carbon corrosion and its impact on performance degradation during simulated start-stop operations for the proton exchange membrane fuel cell
    Liu, Fengfeng
    Gao, Ziliang
    Su, Jinzhan
    Guo, Liejin
    ELECTROCHIMICA ACTA, 2023, 468
  • [7] Influence of the microporous layer on carbon corrosion in the catalyst layer of a polymer electrolyte membrane fuel cell
    Spernjak, Dusan
    Fairweather, Joseph
    Mukundan, Rangachary
    Rockward, Tommy
    Borup, Rodney L.
    JOURNAL OF POWER SOURCES, 2012, 214 : 386 - 398
  • [8] Modelling and simulations of carbon corrosion during operation of a Polymer Electrolyte Membrane fuel cell
    Hu, Jingwei
    Sui, P. C.
    Kumar, Sanjiv
    Djilali, Ned
    ELECTROCHIMICA ACTA, 2009, 54 (23) : 5583 - 5592
  • [9] Local Catalyst Support Degradation during Polymer Electrolyte Fuel Cell Start-Up and Shutdown
    Kreitmeier, Stefan
    Wokaun, Alexander
    Buechi, Felix N.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2012, 159 (11) : F787 - F793
  • [10] Preparation of catalyst for a polymer electrolyte fuel cell using a novel spherical carbon support
    Eguchi, Mika
    Okubo, Atsuhiko
    Yamamoto, Shun
    Kikuchi, Mayuko
    Uno, Katsuhiro
    Kobayashi, Yoshio
    Nishitani-Gamo, Mikka
    Ando, Toshihiro
    JOURNAL OF POWER SOURCES, 2010, 195 (18) : 5862 - 5867