Hand-held fractional exhaled nitric oxide measurements as a non-invasive indicator of systemic inflammation in Crohn's disease

被引:11
|
作者
Quenon, L. [1 ]
Hindryckx, P. [1 ]
De Vos, M. [1 ]
De Looze, D. [1 ]
Joos, G. [2 ]
Brusselle, G. [2 ]
Peeters, H. [1 ]
机构
[1] Univ Ghent, Fac Med & Hlth Sci, Dept Gastroenterol, B-9000 Ghent, Belgium
[2] Univ Ghent, Fac Med & Hlth Sci, Dept Resp Med, B-9000 Ghent, Belgium
来源
JOURNAL OF CROHNS & COLITIS | 2013年 / 7卷 / 08期
关键词
Crohn's disease; Exhaled nitric oxide; Disease activity marker; BOWEL-DISEASE; ACTIVITY INDEX;
D O I
10.1016/j.crohns.2012.09.021
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and aims: Active inflammatory bowel disease (IBD) is associated with increased activity of inducible nitric oxide synthase (iNOS), which increases both mucosal and plasma nitric oxide (NO) levels. Increased fractional exhaled nitric oxide (FeNO) levels have been described in patients with IBD. Currently, hand-held FeNO measurement devices are available, enabling a fast in-office analysis of this non-invasive disease activity marker. In this pilot study, we investigated the utility of in-office FENO measurements in patients with Crohn's disease (CD). Methods: Fifty CD patients and 25 healthy controls (HC) were included, all of whom were free of atopic or pulmonary disorders and respiratory symptoms at the time of inclusion. The Crohn's disease activity index (CDAI) was calculated, and the inflammatory parameters and fecal calprotectin levels were assessed. FeNO was measured with a hand-held device. Results: A significant increase in FeNO (median, [interquartile range]) was observed in steroid-free CD patients with clinically active disease (CDAI > 150; 22 [8] ppb) compared with CD patients in clinical remission (CDAI<150; 11 [6] ppb; P<0.001) and HC's (17 [9] ppb; P<0.05). Active CD patients treated with corticosteroids had significantly lower FeNO compared with active CD patients without steroids (12 [10] ppb vs 25 [19] ppb; P < 0.05). FeNO displayed a strong correlation with the CDAI (R=0.68; P<0.001). Fair correlations were found between FeNO and several systemic inflammatory markers, but no significant correlation was found with fecal calprotectin. Conclusion: This pilot study suggests that hand-held FeNO measurements could be an attractive non-invasive indicator of systemic inflammation in Crohn's disease. Crown Copyright (C) 2012 Published by Elsevier B.V. on behalf of European Crohn's and Colitis Organisation. All rights reserved.
引用
收藏
页码:644 / 648
页数:5
相关论文
共 50 条
  • [1] Nasal fractional exhaled nitric oxide analysis with a novel hand-held device
    Weschta, Michael
    Deutschle, Tom
    Riechelmann, Herbert
    RHINOLOGY, 2008, 46 (01) : 23 - 27
  • [2] Assessment of exhaled nitric oxide by a new hand-held device
    Antus, Balazs
    Horvath, Ildiko
    Barta, Imre
    RESPIRATORY MEDICINE, 2010, 104 (09) : 1377 - 1380
  • [3] Non-invasive electrochemical hand-held biosensor as diagnostic indicator of dental diseases
    Ivnitski, D
    Sitdikov, R
    Ivnitski, N
    ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (03) : 225 - 229
  • [4] Exhaled Nitric Oxide (FeNO) as a Non-Invasive Marker of Airway Inflammation
    Munakata, Mitsuru
    ALLERGOLOGY INTERNATIONAL, 2012, 61 (03) : 365 - 372
  • [5] Non-invasive monitoring of inflammation in asthma using exhaled nitric oxide
    Amirav, Israel
    Zacharasiewicz, Angella
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2008, 10 (02): : 146 - 148
  • [6] Exhaled nitric oxide measurements: Correction equation to compare hand-held device to stationary analyzer
    Pizzimenti, Stefano
    Bugiani, Massimiliano
    Piccioni, Pavilio
    Heffler, Enrico
    Carosso, Aurelia
    Guida, Giuseppe
    Rolla, Giovanni
    RESPIRATORY MEDICINE, 2008, 102 (09) : 1272 - 1275
  • [7] Validation of a hand-held exhaled nitric oxide analyzer for use in children
    McGill, Claire
    Malik, Gulshan
    Turner, Stephen W.
    PEDIATRIC PULMONOLOGY, 2006, 41 (11) : 1053 - 1057
  • [8] Reliability of a new hand-held device for the measurement of exhaled nitric oxide
    Khalili, B.
    Boggs, P. B.
    Bahna, S. L.
    ALLERGY, 2007, 62 (10) : 1171 - 1174
  • [9] Measurements of Nasal Fractional Exhaled Nitric Oxide with a Hand-held Device in Patients with Allergic Rhinitis: Relation to Cedar Pollen Dispersion and Laser Surgery
    Takeno, Sachio
    Noda, Noriaki
    Hirakawa, Katsuhiro
    ALLERGOLOGY INTERNATIONAL, 2012, 61 (01) : 93 - 100
  • [10] Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children
    K Alving
    C Janson
    L Nordvall
    Respiratory Research, 7