Dual gradient echo in-phase and out of phase sequences in assessment of hepatic iron overload in patients with beta-thalassemia, would be better?

被引:0
|
作者
Aboughonaim, Ahmed Ali Mohamed [1 ,4 ]
Ettaby, Ashraf Naguib [2 ,5 ]
El-Noueum, Khaled Ibrahim [2 ,5 ]
Hassab, Hoda [3 ,5 ]
Emara, Doaa M. [2 ,5 ]
机构
[1] Port Said Univ, Fac Med, Dept Radiodiag, Port Said, Egypt
[2] Alexandria Univ, Fac Med, Dept Radiodiag, Alexandria, Egypt
[3] Alexandria Univ, Fac Med, Hematol Unit, Dept Pediat, Alexandria, Egypt
[4] Port Said Univ, Fac Med, 23 December St, Port Said 42534, Egypt
[5] Alexandria Univ, Fac Med, Champoll St,El Khartoum Sq,El Azareeta Med Campus, Alexandria 21131, Egypt
关键词
MRI; Hepatic iron overload; Thalassemia; R2*relaxometry; Dual-phase gradient echo; rSI; MAGNETIC-RESONANCE; LIVER IRON; MYOCARDIAL IRON; MRI; QUANTIFICATION; T2-ASTERISK; GUIDELINES; DEPOSITION; ACCURACY; IMPACT;
D O I
10.1016/j.ejrad.2022.110412
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the diagnostic accuracy of the dual gradient-echo (GRE) in- and out-of-phase sequences as a quantitative tool for hepatic iron overload in comparison with MRI R2* relaxometry in paediatric patients with beta-thalassemia. Method: Sixty-three patients with beta-thalassemia major (transfusion-dependent) or beta-thalassemia intermedia (transfusion- and non-transfusion-dependent) were referred from the paediatric department (haematology unit) to the radiology department at a university hospital. The paediatrician conducted a clinical examination for the studied group, assessed their laboratory data, conducted R2* relaxometry and dual gradient echo sequences to calculate R2* and relative signal intensity index at the axial mid-section of the liver, and studied their correlation. A 1.5 Tesla MR scanner was used (Achieva; Philips Medical Systems, the Netherlands). Data were fed to the computer and analysed using the IBM SPSS software package version 20.0 (Armonk, NY: IBM Corp). The Kolmogorov-Smirnov test was used to verify the normality of distribution. The significance of the results was determined at the 5% level. The Chi-square, Fisher's exact correction, Pearson coefficient, and Bland-Altman tests were used. Results: Dual gradient-echo in- and out-of-phase sequences using visual assessment accurately assessed 93.65% of our patient group with hepatic iron overload. A significant correlation was found between the relative signal intensity index and hepatic MRI R2* relaxometry (p < 0.001, r = 0.861). Conclusions: Dual gradient-echo in and out-of-phase sequences are good imaging tools for hepatic iron detection and quantification. These sequences showed good correlation with R2* relaxometry (r = 0.861, p < 0.001).
引用
收藏
页数:7
相关论文
共 14 条
  • [1] Dual-echo TFE MRI for the assessment of myocardial iron overload in beta-thalassemia major patients
    Hazirolan, Tuncay
    Eldem, Gonca
    Uenal, Sule
    Akpinar, Burcu
    Guemruek, Fatma
    Alibek, Sedat
    Haliloglu, Mithat
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2010, 16 (01) : 59 - 62
  • [2] Assessment of the relationship between fragmented QRS and cardiac iron overload in patients with beta-thalassemia major
    Bayar, Nermin
    Kurtoglu, Erdal
    Arslan, Sakir
    Erkal, Zehra
    Cay, Serkan
    Cagirci, Goksel
    Deveci, Burak
    Kucukseymen, Selcuk
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2015, 15 (02): : 132 - 136
  • [3] Gradient-echo magnetic resonance imaging study of pancreatic iron overload in young Egyptian beta-thalassemia major patients and effect of splenectomy
    Matter, Randa M.
    Allam, Khalid E.
    Sadony, Amany M.
    DIABETOLOGY & METABOLIC SYNDROME, 2010, 2
  • [4] Gradient-echo magnetic resonance imaging study of pancreatic iron overload in young Egyptian beta-thalassemia major patients and effect of splenectomy
    Randa M Matter
    Khalid E Allam
    Amany M Sadony
    Diabetology & Metabolic Syndrome, 2
  • [5] Effect of echo-sampling strategy on the accuracy of out-of-phase and in-phase multiecho gradient-Echo MRI hepatic fat fraction estimation
    Levin, Yakir S.
    Yokoo, Takeshi
    Wolfson, Tanya
    Gamst, Anthony C.
    Collins, Julie
    Achmad, Emil A.
    Hamilton, Gavin
    Middleton, Michael S.
    Loomba, Rohit
    Sirlin, Claude B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (03) : 567 - 575
  • [6] Biochemical Assessment of Iron Overload Effect on Human Organs (Liver, Heart, Brain) In Patients with Beta-Thalassemia Major and Thalassemia Intermediate
    Almuttrek, Ahmed Jasim M.
    Karaipekli, Ali
    Abbas, Hamid Jaddoa
    Jihad, Waqar Sabeeh
    JOURNAL OF POPULATION THERAPEUTICS AND CLINICAL PHARMACOLOGY, 2023, 30 (06): : E421 - E428
  • [7] Dual Gradient-echo In-phase and Opposed-phase Magnetic Resonance Imaging to Evaluate Lipomatous Metaplasia in Patients with Old Myocardial Infarction
    Okayama, Satoshi
    Uemura, Shiro
    Sugimoto, Hiroyuki
    Enomoto, Satoshi
    Onoue, Kenji
    Omori, Sawako
    Soeda, Tsunenari
    Somekawa, Satoshi
    Ishigami, Ken-ichi
    Watanabe, Makoto
    Nakajima, Tamio
    Kubota, Yasushi
    Saito, Yoshihiko
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2010, 9 (02) : 85 - 89
  • [8] Dual gradient-echo in-phase and opposed-phase hepatic MR imaging: A useful tool for evaluating more than fatty infiltration or fatty sparing
    Merkle, Elmar M.
    Nelson, Rendon C.
    RADIOGRAPHICS, 2006, 26 (05) : 1409 - 1418
  • [9] TOWARD BETTER PATHOPHYSIOLOGICAL CHARACTERIZATION AND THERAPEUTIC SOLUTION IN BETA-THALASSEMIA TRAIT PATIENTS WITH IRON OVERLOAD. PRELIMINARY REPORTS FROM AN ONGOING STUDY
    Busti, F.
    Campostrini, N.
    Badar, S.
    Ferrarini, A.
    Xumerle, L.
    Giuffrida, A. C.
    De Matteis, G.
    Manfredi, R.
    Capelli, P.
    Castagna, A.
    Delledonne, M.
    Olivieri, O.
    Girelli, D.
    HAEMATOLOGICA, 2015, 100 : 596 - 596
  • [10] Diagnostic value of 3D T1-weighted gradient-echo and 2D T1-weighted in-phase and out-of-phase gradient-echo sequences for appendicitis diagnosis in pregnant women
    Hung, Nguyen Duy
    Dung, Le Thanh
    Dung, Nguyen-Thi Kim
    Ha Khuong, Nguyen
    Anh, Nguyen Hai
    Duc, Nguyen Minh
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2023, 13 : 1 - 6