Comparison of ultrasound-guided versus blind glenohumeral injections: a cadaveric study

被引:54
|
作者
Patel, Deepan N. [1 ]
Nayyar, Samir [1 ]
Hasan, Saqib [1 ]
Khatib, Omar [1 ]
Sidash, Stanislav [1 ]
Jazrawi, Laith M. [1 ]
机构
[1] NYU, Div Sports Med, Hosp Joint Dis, New York, NY USA
关键词
Glenohumeral; injection; shoulder; ultrasound guided; cadaveric; accuracy; time assessment; INTRAARTICULAR INJECTION; ACCURACY; SHOULDER; JOINT; ARTHROGRAPHY; PLACEMENT;
D O I
10.1016/j.jse.2011.11.026
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Intra-articular glenohumeral (GH) injections are important for diagnostic and therapeutic purposes. It has been suggested that ultrasound guided injections are more accurate than blind or freehand injections. This study assessed the accuracy of ultrasound-guided GH injections compared with freehand injections in fresh cadavers. Methods: The study used 80 shoulder specimens from fresh cadavers. Ultrasound guidance was used to inject radiopaque contrast in 40 shoulders, and freehand technique was used in the remaining 40. All injections were performed by 2 surgeons (A and B) through a posterior approach. After the injections, radiographs were obtained of the specimens to assess the accuracy of the injections. Results: Sixty-six of 80 (82.5%) injections were accurately administered into the GH joint. Ultrasound-guided injections were accurate in 37 of 40 specimens (92.5%) compared with freehand injections, which were accurate in only 29 of 40 specimens (72.5%; P=.02). Both surgeons independently had higher accuracy using ultrasound-guidance compared with the freehand technique (surgeon A: 90% vs 65%, P=0.058; surgeon B: 95% vs 80%, P=0.15). The average time for injections was 52 seconds by the freehand technique and 166 seconds using ultrasound guidance (P<0.001). Conclusions: The data from this cadaveric study suggest that ultrasound-guided injections are more accurate at reaching the GH joint than freehand injections. The ultrasound-guided injections took substantially longer to administer. Once familiar with the technique, surgeons can expect improved accuracy and efficacy of GH joint injections using ultrasound guidance in the clinical setting. Level of evidence: Basic Science Study, Anatomic Study. (C) 2012 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1664 / 1668
页数:5
相关论文
共 50 条
  • [1] Comparison of ultrasound-guided versus blind interventions for supraspinatus tendinopathy: a cadaveric study
    Abat, F.
    Campos, J.
    Torras, J.
    Madruga, M.
    Planells, G.
    Rodriguez-Baeza, A.
    MLTJ-MUSCLES LIGAMENTS AND TENDONS JOURNAL, 2019, 9 (03): : 328 - 337
  • [2] Ultrasound-guided versus blind temporomandibular joint injections: a pilot cadaveric evaluation
    Cha, Y. H.
    O, J.
    Park, J. -K.
    Yang, H. -M.
    Kim, S. H.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 48 (04) : 540 - 545
  • [3] Accuracy of Ultrasound-Guided Versus Palpation-Guided Acromioclavicular Joint Injections: A Cadaveric Study
    Peck, Evan
    Lai, Jim K.
    Pawlina, Wojciech
    Smith, Jay
    PM&R, 2010, 2 (09) : 817 - 821
  • [4] Ultrasound-guided versus blind interventions in patellar tendon lesions: a cadaveric study
    Abat, Ferran
    Alfredson, Hakan
    Campos, Jocelio
    Planells, Gabriel
    Torras, Jordi
    Madruga-Parera, Marc
    Rodriguez-Baeza, Alfonso
    SKELETAL RADIOLOGY, 2021, 50 (05) : 967 - 972
  • [5] Ultrasound-guided versus blind interventions in patellar tendon lesions: a cadaveric study
    Ferran Abat
    Hakan Alfredson
    Jocelio Campos
    Gabriel Planells
    Jordi Torras
    Marc Madruga-Parera
    Alfonso Rodriguez-Baeza
    Skeletal Radiology, 2021, 50 : 967 - 972
  • [6] Ultrasound-guided versus Nonguided Tibiotalar Joint and Sinus Tarsi Injections: A Cadaveric Study
    Wisniewski, Steve J.
    Smith, Jay
    Patterson, Denis G.
    Carmichael, Stephen W.
    Pawlina, Wojciech
    PM&R, 2010, 2 (04) : 277 - 281
  • [7] Accuracy of ultrasound-guided versus fluoroscopically guided contrast-controlled piriformis injections - A cadaveric study
    Finnoff, Jonathan T.
    Hurdle, Mark Friedrich B.
    Smith, Jay
    JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (08) : 1157 - 1163
  • [8] Cadaveric comparison of the accuracy of ultrasound-guided versus 'blind' perineural injection of the tibial nerve in horses
    van der Laan, Maylin
    Raes, Els
    Oosterlinck, Maarten
    VETERINARY JOURNAL, 2021, 269
  • [9] Comparing the accuracy and efficacy of ultrasound-guided versus blind injections of steroid in the glenohumeral joint in patients with shoulder adhesive capsulitis
    Raeissadat, Seyed Ahmad
    Rayegani, Seyed Mansoor
    Langroudi, Taraneh Faghihi
    Khoiniha, Maryam
    CLINICAL RHEUMATOLOGY, 2017, 36 (04) : 933 - 940
  • [10] Comparing the accuracy and efficacy of ultrasound-guided versus blind injections of steroid in the glenohumeral joint in patients with shoulder adhesive capsulitis
    Seyed Ahmad Raeissadat
    Seyed Mansoor Rayegani
    Taraneh Faghihi Langroudi
    Maryam Khoiniha
    Clinical Rheumatology, 2017, 36 : 933 - 940