Extended 12-core prostate biopsy increases both the detection of prostate cancer and the accuracy of Gleason score

被引:84
|
作者
Elabbady, AA [1 ]
Khedr, MM
机构
[1] Univ Alexandria, Fac Med, Dept Urol, Alexandria 21113, Egypt
[2] Univ Alexandria, Fac Med, Dept Pathol, Alexandria 21113, Egypt
关键词
prostate biopsy; prostate cancer; Gleason score;
D O I
10.1016/j.eururo.2005.08.013
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the effect of extended 12-core prostate biopsy in improving the detection rate of prostate cancer and increasing the accuracy of Gleason score. Methods: This study included 113 patients who underwent TRUS-guided lateral sextant biopsy (group I) and 176 patients who underwent extended 12-core biopsy (group II). Inclusion criteria for prostate biopsy were elevated serum PSA levels (> 3.0 ng/ml) and/or suspicious digital rectal examination (DRE). Results: Clinical characteristics were similar in both groups. Cancer was detected in 28 (24.8%) and 64 (36.4%) patients in group I and II respect tively, chi(2) = 4.26, p = 0.039. Among patients with cancer in group I, 14 were treated by radical prostatectomy (RP). The median Gleason sum was 6 (range 3-8) and 7 (range 5-9) for needle and prostatectomy specimens respectively. There was an agreement between the biopsy and prostatectomy Gleason sum in 7 (50%) patients while the biopsy Gleason sum was lower in 7 (50%) cases. Among patients with cancer in group II, 27 were treated by RP. The median and the range of Gleason sum was the same for needle and prostatectomy specimen (median 6, range 4-9). There was an agreement between the biopsy and prostatectomy specimen in 23 (85.2%) patients while the biopsy sum was lower than prostatectomy in 4 (14.8%) patients. The agreement between the biopsy and prostatectomy specimen was significantly higher in group II (82.5%) than group I (50%), Fisher's Exact Test, p = 0.026. Conclusion: Extended 12-core prostate biopsy significantly increases both the detection rate of prostate cancer and the accuracy of biopsy Gleason score. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:49 / 53
页数:5
相关论文
共 50 条
  • [1] Extended 14-cores schematic diagram mapping prostate biopsy increases both the cancer detection rate and the accuracy of Gleason score
    Naravejsakul, K.
    INTERNATIONAL JOURNAL OF UROLOGY, 2019, 26 : 15 - 16
  • [2] HOW RELIABLE IS 12-CORE PROSTATE BIOPSY PROCEDURE IN THE DETECTION OF PROSTATE CANCER?
    Serefoglu, E. C.
    Altinova, S.
    Ugras, N. S.
    Akincioglu, E.
    Asil, E.
    Balbay, M. D.
    EUROPEAN UROLOGY SUPPLEMENTS, 2010, 9 (02) : 54 - 55
  • [3] Transperineal 12-core systematic biopsy in the detection of prostate cancer
    Kojima, M
    Hayakawa, T
    Saito, T
    Mitsuya, H
    Hayase, Y
    INTERNATIONAL JOURNAL OF UROLOGY, 2001, 8 (06) : 301 - 307
  • [4] How reliable is 12-core prostate biopsy procedure in the detection of prostate cancer?
    Serefoglu, Ege Can
    Altinova, Serkan
    Ugras, Nevzat Serdar
    Akincioglu, Egemen
    Asil, Erem
    Balbay, Derya
    CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL, 2013, 7 (5-6): : E293 - E298
  • [5] GLEASON SCORE UPGRADING ON MRI/ULTRASOUND FUSION GUIDED PROSTATE BIOPSY VERSUS SYSTEMATIC 12-CORE TRUS BIOPSY
    Siddiqui, M. Minhaj
    Rais-Bahrami, Soroush
    Stamatakis, Lambros
    Vourganti, Srinivas
    Hoang, Anthony
    Nix, Jeffrey
    Hong Truong
    Walton-Diaz, Annerleim
    Logan, Jennifer
    Weintraub, Michael
    Turkbey, Baris
    Choyke, Peter
    Wood, Bradford
    Pinto, Peter
    JOURNAL OF UROLOGY, 2013, 189 (04): : E910 - E910
  • [6] Sextant Systematic Biopsy Versus Extended 12-Core Systematic Biopsy in Combined Biopsy for Prostate Cancer
    Chung, Jae Hoon
    Song, Wan
    Kang, Minyong
    Sung, Hyun Hwan
    Jeon, Hwang Gyun
    Jeong, Byong Chang
    Seo, Seong I. L.
    Jeon, Seong Soo
    Lee, Hyun Moo
    Park, Byung Kwan
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2024, 39 (07)
  • [7] Optimizing Prostate Cancer Detection: 8 Versus 12-Core Biopsy Protocol
    de la Rosette, Jean J. M. C. H.
    Wink, Margot H.
    Mamoulakis, Charalampos
    Wondergem, Niels
    ten Kate, Fiebo J. C.
    Zwinderman, Koos
    de Reijke, Theo M.
    Wijkstra, Hessel
    JOURNAL OF UROLOGY, 2009, 182 (04): : 1329 - 1335
  • [8] Peripheral biopsies maximize cancer detection in 12-core prostate biopsy protocols
    Nature Clinical Practice Urology, 2006, 3 (11): : 571 - 571
  • [9] Concordance of MRI-Guided Fusion and Systematic 12-Core Prostate Biopsy for the Detection of Prostate Cancer
    Parsons, Matthew
    Sandhu, Zoya
    Foy, Bridget
    Chan, Ernest
    Crawford, Bryan
    Petersen, Libby
    Romney, Benjamin
    Sommers, Daniel
    Bishoff, Jay
    Lynch, Steven
    Mclean, Logan
    Gill, David
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [10] Optimizing Prostate Cancer Detection: 8 Versus 12-Core Biopsy Protocol REPLY
    不详
    JOURNAL OF UROLOGY, 2009, 182 (04): : 1336 - 1336