End-tidal PCO2 monitoring via nasal cannulae in pediatric patients: Accuracy and sources of error

被引:38
|
作者
Friesen, RH [1 ]
Alswang, M [1 ]
机构
[1] CHILDRENS HOSP,DEPT ANESTHESIOL & PEDIAT CRIT CARE,DENVER,CO 80218
来源
JOURNAL OF CLINICAL MONITORING | 1996年 / 12卷 / 02期
关键词
measurement techniques; capnography; Monitoring; carbon dioxide; blood gases; nasal cannulae; pediatrics;
D O I
10.1007/BF02078136
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective. To assess the correlation and accuracy of end-tidal PCO2 (PetCO(2)) sampled via nasal cannulae in pediatric patients by comparison to the criterion standard PaCO2 and to identify sources of error during PetCO(2) monitoring via nasal cannulae. Methods. PetCO(2) was monitored continuously by sampling end-tidal gas through nasal cannulae that had been designed and manufactured for this purpose in spontaneously breathing children undergoing conscious or deep sedation during either cardiac catheterization (n = 43) or critical care (n = 54). When both the capnographic wave form and the PetCO(2) value had been stable for at least 10 minutes, the PetCO(2) value was recorded while blood was drawn from atl indwelling arterial line for PaCO2 measurement. The effects of age, weight, respiratory rate, oxygen delivery system, airway obstruction, mouth breathing, and cyanotic heart disease were evaluated by linear regression analysis and calculation of absolute bias (PaCO2-PetCO(2)). Results. Mouth breathing, airway obstruction, oxygen delivery through the ipsilateral nasal cannula, and cyanotic heart disease adversely affected accuracy. In patients without those factors, PetCO(2) correlated well with PaCO2 (R(2) = 0.994), and absolute bias was 3.0 +/- 1.8 mmHg. Conclusions. Several factors - some controllable and all recognizable - affect the accuracy of PetCO(2) monitored via nasal cannulae in pediatric patients. When these factors are not present, PetCO(2) correlates well with PaCO2 and appears to be a useful monitor of ventilatory status during conscious or deep sedation.
引用
收藏
页码:155 / 159
页数:5
相关论文
共 50 条
  • [1] ACCURACY OF END-TIDAL AND TRANSCUTANEOUS PCO2 MONITORING DURING SLEEP
    SANDERS, MH
    KERN, NB
    COSTANTINO, JP
    STILLER, RA
    STROLLO, PJ
    STUDNICKI, KA
    COATES, JA
    RICHARDS, TJ
    CHEST, 1994, 106 (02) : 472 - 483
  • [2] The Accuracy of Transcutaneous PCO2 in Subjects With Severe Brain Injury: A Comparison With End-Tidal PCO2
    Rosier, Sebastien
    Launey, Yoann
    Bleichner, Jean-Paul
    Laviolle, Bruno
    Jouve, Alice
    Malledant, Yannick
    Seguin, Philippe
    RESPIRATORY CARE, 2014, 59 (08) : 1242 - 1247
  • [3] Continuous non-invasive PCO2 monitoring in weaning patients: Transcutaneous is advantageous over end-tidal PCO2
    Schwarz, Sarah B.
    Windisch, Wolfram
    Magnet, Friederike S.
    Schmoor, Claudia
    Karagiannidis, Christian
    Callegari, Jens
    Huttmann, Sophie E.
    Storre, Jan H.
    RESPIROLOGY, 2017, 22 (08) : 1579 - 1584
  • [4] Depression, state NA, and end-tidal pCO2
    Conrad, Ansgar
    Kramer, Marie A.
    Khaylis, Anna
    Wilhelm, Frank H.
    Roth, Walton T.
    Taylor, C. Barr
    BIOLOGICAL PSYCHOLOGY, 2007, 75 (02) : 208 - 209
  • [5] CAN ONE PREDICT ARTERIAL PCO2 FROM END-TIDAL PCO2
    IPYAM, PC
    BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 (04) : 495 - 495
  • [6] END-TIDAL PCO2 DURING CARDIOPULMONARY RESUSCITATION
    WEIL, MH
    GAZMURI, RJ
    KETTE, F
    BISERA, J
    RACKOW, EC
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1990, 263 (06): : 814 - 815
  • [7] Is end-tidal PCO2 an acceptable single measurement substitute for arterialised PCO2?
    Marshall, MJ
    Kendrick, AH
    THORAX, 2001, 56 : 66 - 66
  • [8] CAN ONE PREDICT ARTERIAL PCO2 FROM END-TIDAL PCO2
    FLETCHER, R
    BRITISH JOURNAL OF ANAESTHESIA, 1993, 71 (02) : P316 - P317
  • [9] COMPARISON OF PEDIATRIC END-TIDAL CO2 MEASURED WITH NASAL ORAL CANNULA CIRCUIT AND CAPILLARY PCO2
    ABRAMO, TJ
    COWAN, MR
    SCOTT, SM
    PRIMM, PA
    WIEBE, RA
    SIGNS, M
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1995, 13 (01): : 30 - 33
  • [10] MEASUREMENT OF END-TIDAL PCO2 AND PO2
    GARDNER, W
    BIOFEEDBACK AND SELF-REGULATION, 1994, 19 (02): : 103 - 113