An Empirical Modeling of Electromagnetic Pollution on a University Campus

被引:0
|
作者
Kurnaz, Cetin [1 ]
机构
[1] Ondokuz Mayis Univ, Dept Elect & Elect Engn, TR-55139 Samsun, Turkey
关键词
Electric field strength; electromagnetic (EM) measurement; EM pollution; statistical analysis;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, electric field strength (E) levels were measured on Ondokuz Mayis University's Kurupelit Campus and Faculty of Medicine Hospital in Samsun, Turkey between years 2013-2015. 840 short term and two long term measurements were performed using PMM-8053 and SRM-3006 at 60 different locations of which 30 were on both the campus and hospital. The results show that the measured E levels are far below the limits that are determined by ICNIRP. Based on the measurement analysis, a novel empirical model that allows characterizing the total E of medium using three main electromagnetic (EM) sources with 99.7% accuracy was proposed. Then other new models to estimate main distribution of total E were suggested. With the use of these models, E values of main pollution sources can be estimated with 95.2% accuracy and easily lead to prediction of future EM pollution levels.
引用
收藏
页码:111 / 114
页数:4
相关论文
共 50 条
  • [1] An empirical modeling of electromagnetic pollution on a university campus
    [J]. Kurnaz, Çetin (ckurnaz@omu.edu.tr), 2018, Applied Computational Electromagnetics Society (ACES) (33):
  • [2] An Empirical Modeling of Electromagnetic Pollution on a University Campus
    Kurnaz, Çetin
    [J]. Applied Computational Electromagnetics Society Newsletter, 2018, 33 (01): : 111 - 114
  • [3] LONGTERM ELECTROMAGNETIC FIELD MEASUREMENTS AND POLLUTION MAPS IN A UNIVERSITY CAMPUS
    Karadag, Teoman
    Ozdemir, Ali Riza
    Abbasov, Teymuraz
    [J]. PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2014, 20 (08): : 314 - 318
  • [4] Exposure to Electromagnetic Radiation at the Campus of An Najah University
    Mousa, Allam
    [J]. 2009 IEEE 9TH MALAYSIA INTERNATIONAL CONFERENCE ON COMMUNICATIONS (MICC), 2009, : 154 - 158
  • [5] Monitoring Particulate Pollution in the University of Patras Campus, Greece
    Bloutsos, A. A.
    Yannopoulos, P. C.
    [J]. PERSPECTIVES ON ATMOSPHERIC SCIENCES, 2017, : 861 - 867
  • [6] Study of Environmental Noise Pollution in the University of Dammam Campus
    El-Sharkawy, Mahmoud F.
    Alsubaie, Ali S. R.
    [J]. SAUDI JOURNAL OF MEDICINE & MEDICAL SCIENCES, 2014, 2 (03): : 178 - 184
  • [7] Modeling and Optimal Operation of a University Campus Microgrid
    Dagdougui, Hanane
    Dessaint, Louis
    Gagnon, Ghyslain
    Al-Haddad, Kamal
    [J]. 2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [8] Analysis of Noise pollution level in Enugu campus, of the University of Nigeria
    Egbenta, Idu Robert
    Elugwaraonu, Ngozi Faith
    Ndukwu, Raphael I.
    Okosun, Andrew Egara
    [J]. SAGE OPEN, 2024, 14 (02):
  • [9] Analysis of noise pollution level in a University campus in South India
    Thattai, D.
    Sudarsan, J. S.
    Sathyanathan, R.
    Ramasamy, Visalatchi
    [J]. INTERNATIONAL CONFERENCE ON CIVIL ENGINEERING AND INFRASTRUCTURAL ISSUES IN EMERGING ECONOMIES (ICCIEE 2017), 2017, 80
  • [10] Empirical modeling of campus-wide pedestrian mobility: Observations on the USC campus
    Bhattacharjee, D
    Rao, A
    Shah, A
    Helmy, A
    [J]. VTC2004-FALL: 2004 IEEE 60TH VEHICULAR TECHNOLOGY CONFERENCE, VOLS 1-7: WIRELESS TECHNOLOGIES FOR GLOBAL SECURITY, 2004, : 2887 - 2891