Experimental analysis of the energy performance of a full-scale PCM glazing prototype

被引:113
|
作者
Goia, Francesco [1 ]
Perino, Marco [2 ]
Serra, Valentina [2 ]
机构
[1] Norwegian Univ Sci & Technol, Fac Architecture & Fine Arts, Res Ctr Zero Emiss Bldg, N-7491 Trondheim, Norway
[2] Politecn Torino, Dept Energy DENERG, TEBE Res Grp, I-10129 Turin, Italy
关键词
PCM; Advanced glazing; Latent heat thermal energy storage; Passive solar heating; Fenestration; Energy performance; THERMAL PERFORMANCE; SYSTEM; FACADE; GLASS; WINDOWS; DESIGN; COMPOSITE; EMITTANCE; MODEL; PANEL;
D O I
10.1016/j.solener.2013.12.002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper deals with the development and use of innovative glazing systems that utilize Phase Change Material (PCM) to achieve dynamic and responsive behaviour. The coupling of a PCM and glass panes could be a way of improving the low thermal inertia of fenestrations and could be an effective way of collecting, storing and exploiting solar energy at a building scale. In the present work, a simple prototype of a PCM glazing system has been proposed and its energy performance has been analysed and compared with a conventional fenestration. The two glazing technologies were installed on an south facing outdoor test cell, in a temperate sub-continental climate. The surface temperatures, transmitted irradiances and heat fluxes of both the PCM glazing and the reference fenestration were measured during an extensive experimental campaign. Summer, Mid-season and Winter days were considered during the analysis, in both sunny and cloudy weather conditions, in order to assess the energy performance of the PCM glazing under different boundary conditions. The experimental results have highlighted a good ability of the PCM glazing to store solar energy and to smooth and delay peak values of the total heat flux. In summer the PCM prototype allows the energy gain to be lowered by more than 50%, compared to the traditional fenestration. In winter, a suitable reduction in the heat loss during the day can be observed, but the direct solar gain is also drastically reduced and the application of this technology for passive solar heating purpose might not always be effective. The obtained results have pointed out the promising performance of PCM glazing, even though a careful integration of the PCM glazing component with the control strategies of the indoor air temperature (e.g. night cooling) is necessary. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:217 / 233
页数:17
相关论文
共 50 条
  • [1] Experimental Assessment of Ocean Salinity and Temperature Energy Conversion (OSTEC) Full-Scale Prototype
    Lee, Shu Kim
    Chong, Harry Lye Hin
    Dayou, Jedol
    Saleh, Ejria
    [J]. TECHNO-OCEAN 2016: RETURN TO THE OCEANS, 2016, : 16 - 21
  • [2] Experimental analysis of an advanced dynamic glazing prototype integrating PCM and thermotropic layers
    Goia, Francesco
    Bianco, Lorenza
    Cascone, Ylenia
    Perino, Marco
    Serra, Valentina
    [J]. PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2013), 2014, 48 : 1272 - 1281
  • [3] Numerical analysis in a full-scale thermal energy storage tank with dual PCM capsules
    Lee, Yong Tae
    Kim, Min Ho
    Lee, Seung Soo
    Gim, Jiwon
    Chung, Jae Dong
    [J]. ENERGY AND BUILDINGS, 2019, 204
  • [4] A full-scale experimental study concerning the moisture condensation on building glazing surface
    Nguyen, Chi-Kien
    Teodosiu, Catalin
    Kuznik, Frederic
    David, Damien
    Teodosiu, Raluca
    Rusaouen, Gilles
    [J]. BUILDING AND ENVIRONMENT, 2019, 156 : 215 - 224
  • [5] MECHANICAL PERFORMANCE OF FULL-SCALE PROTOTYPE QUADRUPOLE MAGNETS FOR THE SSC
    Cortella, J. M.
    Devred, A.
    Wandesforde, A.
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1993, 3 (01) : 699 - 704
  • [6] Experimental and numerical investigations on the energy and structural performance of a full-scale energy utility tunnel
    Kong, Gangqiang
    Wu, Di
    Wei, Yeqing
    [J]. TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 139
  • [7] Thermal and energy performance evaluation of a full-scale test cabin equipped with PCM embedded radiant chilled ceiling
    Mousavi, Seyedmostafa
    Rismanchi, Behzad
    Brey, Stefan
    Aye, Lu
    [J]. BUILDING AND ENVIRONMENT, 2023, 237
  • [8] Energetic efficiency of room wall containing PCM wallboard: A full-scale experimental investigation
    Kuznik, Frederic
    Virgone, Joseph
    Roux, Jean-Jacques
    [J]. ENERGY AND BUILDINGS, 2008, 40 (02) : 148 - 156
  • [9] EXPERIMENTAL MODAL ANALYSIS OF A FULL-SCALE ROTATING FAN
    Jorajuria, Corentin
    Gibert, Claude
    Thouverez, Fabrice
    Esteves, Cecile
    [J]. PROCEEDINGS OF ASME TURBO EXPO 2022: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2022, VOL 8B, 2022,
  • [10] Performance of a full-scale energy pile for underground solar energy storage
    Wu, Di
    Kong, Gangqiang
    Liu, Hanlong
    Jiang, Qiang
    Yang, Qing
    Kong, Liang
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2021, 27