Validation of Renal Artery Dimensions Measured by Magnetic Resonance Angiography in Patients Referred for Renal Sympathetic Denervation

被引:3
|
作者
van Kranenburg, Matthijs [1 ,2 ]
Karanasos, Antonis [1 ]
Chelu, Raluca Gabriela [1 ,2 ]
van der Heide, Elco [1 ]
Ouhlous, Mohamed [2 ]
Nieman, Koen [1 ,2 ]
van Mieghem, Nicolas [1 ]
Krestin, Gabriel [2 ]
Niessen, Wiro [2 ,3 ]
Zijlstra, Felix [1 ]
van Geuns, Robert-Jan [1 ,2 ]
Daemen, Joost [1 ]
机构
[1] Erasmus MC, Dept Cardiol, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus MC, Dept Radiol, NL-3000 CA Rotterdam, Netherlands
[3] Erasmus MC, Dept Med Informat, NL-3000 CA Rotterdam, Netherlands
关键词
Renal artery; percutaneous renal sympathetic denervation; magnetic resonance angiography; intravascular ultrasound; RESISTANT HYPERTENSION; SEMIAUTOMATED MEASUREMENT; MR-ANGIOGRAPHY; STENOSIS; REPRODUCIBILITY; DIAGNOSIS; TRIAL;
D O I
10.1016/j.acra.2015.03.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Magnetic resonance angiography (MRA) is a well-established modality for the assessment of renal artery stenosis. Using dedicated quantitative analyses, MRA can become a useful tool for assessing renal artery dimensions in patients referred for renal sympathetic denervation (RDN) and for providing accurate measurements of vascular response after RDN. The purpose of this study was to test the reproducibility of a novel MRA quantitative imaging tool and to validate these measurements against intravascular ultrasound (NUS). Materials and Methods: In nine patients referred for renal denervation, renal artery dimensions were measured. Bland-Altman analysis was used to assess the intraobserver and interobserver reproducibility. Results: Mean lumen diameter was 5.8 +/- 0.7 mm, with a very good intraobserver and interobserver variability of 0.7% (reproducibility: bias, 0 mm; standard deviation [SD], 0.1 mm) and 1.2% (bias, 0 mm; SD, 0.1 mm), respectively. Mean total lumen volume was 1035.3 +/- 403.6 mm(3) with good intraobserver and interobserver variability of 2.9% (bias, -9.7 mm(3); SD, 34.0 mm(3)) and 2.8% (bias, -11.4 mm(3); SD, 42.4 mm(3)). The correlation (Pearson R) between mean lumen diameter measured with MRA and IVUS was 0.750 (P = .002). Conclusions: Using a novel MRA quantitative imaging tool, renal artery dimensions can be measured with good reproducibility and accuracy. MRA-derived diameters and volumes correlated well with IVUS measurements.
引用
收藏
页码:1106 / 1114
页数:9
相关论文
共 50 条
  • [1] Renal Sympathetic Denervation: Potential Role of Noncontrast Magnetic Resonance Angiography
    Pua, Uei
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 23 (06) : 850 - 852
  • [2] Renal artery and parenchymal changes after renal denervation: assessment by magnetic resonance angiography
    Margreet F. Sanders
    Pieter Jan van Doormaal
    Martine M. A. Beeftink
    Michiel L. Bots
    Fadl Elmula M. Fadl Elmula
    Jesse Habets
    Frank Hammer
    Pavel Hoffmann
    Lotte Jacobs
    Patrick B. Mark
    Alexandre Persu
    Jean Renkin
    Giles Roditi
    Wilko Spiering
    Jan A. Staessen
    Alison H. Taylor
    Willemien L. Verloop
    Eva E. Vink
    Evert-Jan Vonken
    Michiel Voskuil
    Tim Leiner
    Peter J. Blankestijn
    European Radiology, 2017, 27 : 3934 - 3941
  • [3] Renal artery and parenchymal changes after renal denervation: assessment by magnetic resonance angiography
    Sanders, Margreet F.
    van Doormaal, Pieter Jan
    Beeftink, Martine M. A.
    Bots, Michiel L.
    Elmula, M. Fadl
    Habets, Jesse
    Hammer, Frank
    Hoffmann, Pavel
    Jacobs, Lotte
    Mark, Patrick B.
    Persu, Alexandre
    Renkin, Jean
    Roditi, Giles
    Spiering, Wilko
    Staessen, Jan A.
    Taylor, Alison H.
    Verloop, Willemien L.
    Vink, Eva E.
    Vonken, Evert-Jan
    Voskuil, Michiel
    Leiner, Tim
    Blankestijn, Peter J.
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3934 - 3941
  • [4] Serial quantitative magnetic resonance angiography follow-up of renal artery dimensions following treatment by four different renal denervation systems
    van Zandvoorf, Laurens
    van Kranenburg, Matthijs
    Karanasos, Antonios
    Van Mieghem, Nicolas
    Ouhlous, Mohammed
    van Geuns, Robert-Jan
    van Domburg, Ron
    Daemen, Joost
    EUROINTERVENTION, 2017, 12 (18) : E2271 - E2277
  • [5] Renal Sympathetic Denervation in a Previously Stented Renal Artery
    Berra, Elena
    Rabbia, Franco
    Rossato, Denis
    Covella, Michele
    Totaro, Silvia
    Chiara, Fulcheri
    Di Monaco, Silvia
    Veglio, Franco
    JOURNAL OF CLINICAL HYPERTENSION, 2014, 16 (03): : 238 - 239
  • [6] Renal Artery Stenosis After Renal Sympathetic Denervation
    Kaltenbach, Benjamin
    Id, Dani
    Franke, Jennifer C.
    Sievert, Horst
    Hennersdorf, Marcus
    Maier, Jens
    Bertog, Stefan C.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (25) : 2694 - 2695
  • [7] The effects of renal artery diameter in patients with resistant hypertension by renal sympathetic denervation
    Xu Youlong
    Jin Huigen
    Gao Junqing
    Yan Penyong
    Zhang Wenquan
    Wang Mingyu
    Liu Zongjun
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (16) : C177 - C177
  • [8] Safety and Feasibility of Renal Sympathetic Denervation in Patients With Insufficient Renal Artery Length
    Pua, Uei
    Tang, Alex Ah Lak
    Ooi, Yau Wei
    Ho, Hee Hwa
    Ong, Paul Jau Leong
    VASCULAR AND ENDOVASCULAR SURGERY, 2016, 50 (01) : 63 - 67
  • [9] Non-contrast angiography of renal artery in 3T magnetic resonance in patients with refractory arterial hypertension before renal denervation
    Speiser, U.
    Schmiedel, L.
    Henke, C.
    Abas, A.
    Jellinghaus, S.
    Sandfort, V.
    Traenkner, A.
    Schroetter, H.
    Strasser, R. H.
    EUROPEAN HEART JOURNAL, 2013, 34 : 524 - 525
  • [10] Iatrogenic renal artery stenosis after renal sympathetic denervation
    Bacaksiz, Ahmet
    Uyarel, Huseyin
    Jafarov, Parviz
    Kucukbuzcu, Sitki
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 172 (03) : E389 - E390