Prediction and measurement of axial flow fan aerodynamic and aeroacoustic performance in a split-type air-conditioner outdoor unit

被引:27
|
作者
Zhao, Xifeng [1 ]
Sun, Jinju [1 ]
Zhang, Zhi [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian 710049, Peoples R China
[2] Midea Air Conditioning & Refrigerat Grp Co Ltd, Ctr Inst, Foshan 528311, Peoples R China
关键词
Air conditioner; Outdoor unit; Axial flow fan; Computational fluid dynamics; Computational aerodynamic acoustics; Noise reduction; NOISE-REDUCTION;
D O I
10.1016/j.ijrefrig.2012.11.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
The study has focused on outdoor unit noise reduction by fan geometry modification with the refined numerical and experimental approaches. The outlet louver, electric motor and its support are included to refine the flow and acoustic model and a hybrid method incorporating CFD and CAA is used to predict the noise behavior. The fan performance curve is well-predicted; the moderate acoustic power is obtained on the outlet louver, motor support and motor exhibiting a significant contribution to overall noise behavior. The aeroacoustic test is conducted in an anechoic chamber and the obtained results are compared with the semi-anechoic chamber ones, and the unremarkable differences are produced, which indicate the ground floor being of some influence. Both modified fan geometries are effective to reduce the noise but the flanging outer-edge blade is more effective. The noise directivities of three geometry fans are investigated both numerically and experimentally and the produced asymmetric characteristics are analyzed. (C) 2012 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:1098 / 1108
页数:11
相关论文
共 50 条
  • [1] Aerodynamic and aeroacoustic study of collateral axial flow fan system inside outdoor unit of air-conditioner
    Ouyang, Hua
    Tian, Jie
    Wu, Yadong
    Zheng, Zhiming
    Sumio, Shiochi
    Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering, 2007, 43 (10): : 215 - 220
  • [2] On similitude of the cross flow fan in a split-type air-conditioner
    Shih, Yang-Cheng
    Hou, Hung-Chi
    Chiang, Hsucheng
    APPLIED THERMAL ENGINEERING, 2008, 28 (14-15) : 1853 - 1864
  • [3] Investigation of air-flow fields and aeroacoustic noise in outdoor unit for split-type air conditioner
    Jiang, Cai-Ling
    Tian, Jie
    Ouyang, Hua
    Chen, Jiang-Ping
    Chen, Zhi-Jiu
    NOISE CONTROL ENGINEERING JOURNAL, 2006, 54 (03) : 146 - 156
  • [4] Influence of surrounding structures upon the aerodynamic and acoustic performance of the outdoor unit of a split air-conditioner
    Chengjun Wu
    Jiang Liu
    Jie Pan
    Chinese Journal of Mechanical Engineering, 2014, 27 : 836 - 845
  • [5] Influence of Surrounding Structures upon the Aerodynamic and Acoustic Performance of the Outdoor Unit of a Split Air-Conditioner
    WU Chengjun
    LIU Jiang
    PAN Jie
    Chinese Journal of Mechanical Engineering, 2014, (04) : 836 - 845
  • [6] Influence of Surrounding Structures upon the Aerodynamic and Acoustic Performance of the Outdoor Unit of a Split Air-Conditioner
    WU Chengjun
    LIU Jiang
    PAN Jie
    Chinese Journal of Mechanical Engineering, 2014, 27 (04) : 836 - 845
  • [7] Influence of Surrounding Structures upon the Aerodynamic and Acoustic Performance of the Outdoor Unit of a Split Air-Conditioner
    Wu Chengjun
    Liu Jiang
    Pan Jie
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2014, 27 (04) : 836 - 845
  • [8] Effect of condensing unit layout at building re-entrant on split-type air-conditioner performance
    Chow, TT
    Lin, Z
    Liu, JP
    ENERGY AND BUILDINGS, 2002, 34 (03) : 237 - 244
  • [9] An Influence of Air Volume Flow Rate and Temperature Set Point on Performance of Inverter Split-Type Air-Conditioner
    Rachapradit, N.
    Thepa, S.
    Monyakulb, V.
    EXPERIMENTAL TECHNIQUES, 2012, 36 (04) : 18 - 25
  • [10] Performance Monitoring and Prediction of a Domestic Split-type Air Conditioner
    Bantan, Glory M.
    Tangwe, Stephen L.
    Simon, M.
    PROCEEDINGS OF THE 2017 TWENTY FIFTH INTERNATIONAL CONFERENCE ON THE DOMESTIC USE OF ENERGY (DUE), 2017, : 220 - 226