摘要
This paper discusses the results of a study the authors conducted to clarify the usability of an absorber-lined shielded environment (ALSE) as a 150 kHz and lower frequency magnetic field measurement environment using the mirror image method. The magnetic field strength at a measurement point obtained from the mirror image method almost agreed with the measured value and the value obtained by a 3D electromagnetic field analysis, confirming that the mirror image method is effective for estimating the magnetic field strength at a specific measurement point. It was also confirmed that the usability of ALSE for magnetic field measurement depends largely on the distance of the magnetic field source and measurement point from the six walls of the ALSE. The study confirmed that, if the distance between the magnetic field source and measurement point is 1 m or less and they are 1 m or more from the ALSE's wall surfaces, the value measured in an ALSE that can be used to measure electromagnetic emissions from components does not differ by more than 3 dB from the value measured at an outdoor test site (OTS) for automobile evaluation.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Measurement method and measurement equipment development for low-frequency magnetic field
    Gao, Cheng
    Liu, Xiao
    Shi, Li-Hua
    Zhou, Bi-Hua
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (09): : 2272 - 2277
  • [2] Measurement of low-frequency magnetic fields
    Wolfmayr, Holger
    Ziemann, Peter
    Technische Sicherheit, 2017, 7 (11-12): : 54 - 58
  • [3] LOW-FREQUENCY MEASUREMENT OF ANISOTROPY FIELD
    BARBER, WD
    IEEE TRANSACTIONS ON MAGNETICS, 1967, MAG3 (04) : 647 - &
  • [4] Measurement and study of low-frequency noise in TMR magnetic field sensor
    Cao Jiang-Wei
    Wang Rui
    Wang Ying
    Bai Jian-Min
    Wei Fu-Lin
    ACTA PHYSICA SINICA, 2016, 65 (05)
  • [5] Design and measurement of a tunable metasurface low-frequency radar absorber
    Lopez, Tanguy
    Lepetit, Thomas
    Ratni, Badreddine
    Burokur, Shah Nawaz
    JOURNAL OF APPLIED PHYSICS, 2024, 135 (12)
  • [6] A low-frequency ultrathin metamaterial absorber using magnetic material
    Shou, Haijun
    Qi, Buxiong
    Lv, Huanchang
    Feng, Junlang
    Mei, Zhonglei
    JOURNAL OF APPLIED PHYSICS, 2024, 135 (08)
  • [7] LOW-FREQUENCY OSCILLATIONS OF A PLASMA IN A MAGNETIC FIELD
    STEPANOV, KN
    SOVIET PHYSICS JETP-USSR, 1959, 8 (05): : 808 - 811
  • [8] Low-frequency magnetic field fluctuations in Earth's plasma environment observed by THEMIS
    Guicking, L.
    Glassmeier, K. -H.
    Auster, H. -U.
    Narita, Y.
    Kleindienst, G.
    ANNALES GEOPHYSICAE, 2012, 30 (08) : 1271 - 1283
  • [9] PROPOSED LOW-FREQUENCY MEASUREMENT STANDARD FOR MAGNETIC FILMS
    KATZ, HW
    ANDERSON, AH
    KAYSER, W
    GIANOLA, UF
    LOUIS, HP
    GLASER, JH
    OLSON, CD
    HART, J
    WOLF, IW
    IEEE TRANSACTIONS ON MAGNETICS, 1965, MAG1 (03) : 218 - &
  • [10] ON THE LOW-FIELD, LOW-FREQUENCY SUSCEPTIBILITY OF MAGNETIC FLUIDS
    SCAIFE, BKP
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1986, 19 (10) : L195 - L197