A rapid ion chromatography column-switching method for online sample pretreatment and determination of L-carnitine, choline and mineral ions in milk and powdered infant formula

被引:16
|
作者
Wei, Dan [1 ]
Wang, Xu [2 ]
Wang, Nani [3 ]
Zhu, Yan [1 ]
机构
[1] Zhejiang Univ, Dept Chem, Xixi Campus, Hangzhou, Zhejiang, Peoples R China
[2] Hangzhou Med Coll, Dept Med Lab, Hangzhou, Zhejiang, Peoples R China
[3] Zhejiang Acad Tradit Chinese Med, Dept Med, Hangzhou, Zhejiang, Peoples R China
来源
RSC ADVANCES | 2017年 / 7卷 / 10期
关键词
TANDEM MASS-SPECTROMETRY; RUMEN-PROTECTED CHOLINE; SOLID-PHASE EXTRACTION; LIQUID-CHROMATOGRAPHY; CONDUCTIVITY DETECTION; DAIRY-COWS; POTASSIUM; PRODUCTS; SODIUM; PHOSPHOLIPIDS;
D O I
10.1039/c6ra25711a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A simple and rapid column-switching ion chromatography with non-suppressed conductivity detection method was developed for simultaneous determination of L-carnitine, choline and mineral ions (free sodium, potassium, magnesium and calcium ions) in milk and powdered infant formula samples. On-line sample clean-up was achieved on the pretreatment column Dionex IonPac NG1 (50 mm x 4 mm, i.d.), with pretreatment elution (3 mmol L-1 MSA) and washing solution (100% acetonitrile) at a flow rate of 1.0 mL min(-1). After column switching, the separation and determination of analytes were performed using guard column Dionex IonPac SGS (50 mm x 4 mm, i.d.) and analytical column Dionex IonPac SCS (250 mm x 4 mm, i. d.) with an isocratic mobile phase consisting of 3 mmol L-1 MSA and 10% (v/v) acetonitrile, at flow-rate of 1 mL min(-1), followed by non-suppressed conductivity detection. The organic matrices clean-up performance of the proposed method was studied using an UV detector working at 200-400 nm. Under the optimal conditions, detection limits (S/N = 3) ranging from 0.05-0.30 mg L-1, good linearities in the range of 1-100 mg L-1 with a correlation coefficient over 0.9973, and satisfactory recoveries in the range between 94% and 105% with relative standard deviation less than 2.1% for real samples were attainted. The proposed method was successfully applied to rapid, simultaneous, and labour-saving detection of L-carnitine, choline, and mineral ions in milk and powdered infant formula samples.
引用
收藏
页码:5920 / 5927
页数:8
相关论文
共 7 条
  • [1] Determination of betaine, L-carnitine, and choline in human urine using a self-packed column and column-switching ion chromatography with nonsuppressed conductivity detection
    Wei, Dan
    Liu, Junwei
    Guo, Ming
    Zhu, Yan
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (21) : 4246 - 4255
  • [2] Simple determination of betaine, L-carnitine and choline in human urine using self-packed column and column-switching ion chromatography with nonsuppressed conductivity detection
    Wei, Dan
    Zhu, Yan
    Guo, Ming
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (02)
  • [3] Determination of Anions and Cations in Biodiesel with On-line Sample Pretreatment Column-switching Ion Chromatography
    Huang, Zhongping
    Zhao, Xunyan
    Zhu, Zuoyi
    Pan, Zaifa
    Wang, Lili
    Zhu, Yan
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2015, 38 (19) : 1747 - 1752
  • [4] Identification of l-carnitine and its impurities in food supplement formulations by online column-switching liquid chromatography coupled with linear ion trap mass spectrometry
    Wang, Hang
    Xie, Sijun
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (02) : 431 - 441
  • [5] Simultaneous determination of free and total choline and l-carnitine in infant formula using hydrophilic interaction liquid chromatography with tandem mass spectrometry
    Zheng, Hong
    Yu, Wenjiang
    Xue, Xia
    Guo, Zhimou
    Liu, Yanfang
    Yang, Guosheng
    Liu, Yanming
    Zhu, Jianhua
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (16) : 3176 - 3185
  • [6] A flexible ion chromatography column-switching system with a switching time window (STW) calibration program for the determination of myoinositol in infant formula by pulsed amperometric detection
    Zhang, Shuifeng
    Huang, Liying
    Li, Hongyan
    Chen, Xiaozhen
    Wang, Fengli
    Zhang, Donglei
    Zhu, Yan
    ANALYTICAL METHODS, 2015, 7 (06) : 2830 - 2838
  • [7] Simultaneous Determination of Chromium (III), Chromium (VI) in Leather and Cloth by Ion Chromatography with On-line Sample Pretreatment Column-Switching Technique
    He Jie
    Yu Jia-Sheng
    Huang Zhong-Ping
    Zhu Zuo-Yi
    Wang Mu-Hua
    Wang Na-Ni
    Zhang Jia-Jie
    Zhang Pei-Min
    Li Gang
    Zhu Yan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (08) : 1189 - 1194