Computational Modeling of Human Bicuspid Pulmonary Valve Dynamic Deformation in Patients with Tetralogy of Fallot

被引:4
|
作者
Li, Caili [1 ]
Baird, Christopher [2 ]
Yao, Jing [3 ]
Yang, Chun [4 ]
Wang, Liang [5 ]
Yu, Han [5 ]
Geva, Tal [6 ]
Tang, Dalin [5 ,7 ]
机构
[1] Southeast Univ, Sch Math, Nanjing 210096, Jiangsu, Peoples R China
[2] Harvard Med Sch, Boston Childrens Hosp, Dept Cardiac Surg, Boston, MA 02115 USA
[3] Nanjing Med Univ, Dept Cardiol, Affiliated Hosp 1, Nanjing 210029, Jiangsu, Peoples R China
[4] China Informat Tech Designing & Consulting Inst C, Beijing 100048, Peoples R China
[5] Southeast Univ, Sch Biol Sci & Med Engn, Nanjing, Jiangsu, Peoples R China
[6] Harvard Med Sch, Dept Pediat, Boston Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
[7] Worcester Polytech Inst, Dept Math Sci, Worcester, MA 01609 USA
来源
CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES | 2019年 / 119卷 / 01期
关键词
Heart model; pulmonary valve; bicuspid pulmonary valve; tetralogy of Fallot; REPLACEMENT; VENTRICLE; ANATOMY;
D O I
10.32604/cmes.2019.06036
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Pulmonary valve stenosis (PVS) is one common right ventricular outflow tract obstruction problem in patients with tetralogy of Fallot (TOF). Congenital bicuspid pulmonary valve (BPV) is a condition of valvular stenosis, and the occurrence of congenital BPV is often associated with TOF. Dynamic computational models of normal pulmonary root (PR) with tri-leaflet and PR with BPV in patients with TOF were developed to investigate the effect of geometric structure of BPV on valve stress and strain distributions. The pulmonary root geometry included valvular leaflets, sinuses, interleaflet triangles and annulus. Mechanical properties of pulmonary valve leaflet were obtained from biaxial testing of human PV leaflet, and characterized by an anisotropic Mooney-Rivlin model. The complete cardiac cycle was simulated to observe valve leaflet dynamic stress/strain behaviors. Our results indicated that stress/strain distribution patterns of normal tri-leaflet pulmonary valve (TPV) and the BPV were different on valve leaflets when the valve was fully open, but they were similar when valves were completely closed. When the valve was fully open, the BPV maximum stress value on the leaflets was 197.2 kPa, which was 94.3% higher than of the normal TPV value (101.5 kPa). During the valve was fully open, the stress distribution in the interleaflet triangles region of the PR was asymmetric in the BPV model compared with that in the TPV model. The geometric orifice area value in the completely opened position of BPV model was reduced 55.6 % from that of the normal PV. Our initial results demonstrated that valve geometrical variations with BPV may be a potential risk factor linked to occurrence of PVS in patients with TOF. Computational models could be a useful tool in identifying possible linkage between valve disease development and biomechanical factors. Large-scale clinical studies are needed to validate these preliminary findings.
引用
收藏
页码:227 / 244
页数:18
相关论文
共 50 条
  • [1] A bicuspid pulmonary valve associated with tetralogy of fallot
    Nair, V
    Thangaroopan, M
    Cunningham, KS
    Mohammed, SB
    Siu, S
    Williams, WG
    Butany, J
    JOURNAL OF CARDIAC SURGERY, 2006, 21 (02) : 185 - 187
  • [2] Reconstruction of the pulmonary valve and outflow tract with bicuspid prosthesis in tetralogy of Fallot
    Maluf, MA
    Braile, DM
    Silva, C
    Catani, R
    Carvalho, AC
    Buffolo, E
    ANNALS OF THORACIC SURGERY, 2000, 70 (06): : 1911 - 1917
  • [3] Anisotropic Models of Human Pulmonary Root with Bicuspid Pulmonary Valve in Patients with Tetralogy of Fallot: Pulmonary Root Function Assessment and Mechanical Stress Analysis
    Caili Li
    Christopher Baird
    Jing Yao
    Chun Yang
    Liang Wang
    Han Yu
    Tal Geva
    Dalin Tang
    医用生物力学, 2019, 34(S1) (S1) : 88 - 89
  • [4] Tetralogy of Fallot and bicuspid aortic valve: Rare coexistence
    Tyczynski, Pawel
    Michalowska, Ilona
    Kowalik, Ewa
    Spiewak, Mateusz
    Borowiec, Karolina
    Rybicka, Justyna
    Rozanski, Jacek
    Witkowski, Adam
    Hoffman, Piotr
    KARDIOLOGIA POLSKA, 2022, 80 (10) : 1039 - 1041
  • [5] COMPUTATIONAL MODELING OF THE RIGHT VENTRICLE IN REPAIRED TETRALOGY OF FALLOT, BEFORE AND AFTER PULMONARY VALVE REPLACEMENT
    Loke, Yue-Hin
    Yildiran, Ibrahim
    Capuano, Francesco
    Olivieri, Laura
    Balaras, Ilias
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 1367 - 1367
  • [6] Timing of pulmonary valve replacement in patients with tetralogy of Fallot
    Sarikouch, S.
    Dubowy, K. -O.
    Mir, T. S.
    Boettler, P.
    Peters, B.
    Blanz, U.
    Kececioglu, D.
    Beerbaum, P.
    CLINICAL RESEARCH IN CARDIOLOGY, 2008, 97 (09) : 688 - 688
  • [7] An obstructive bicuspid aortic valve in the setting of tetralogy of Fallot with pulmonary atresia: a rare combination
    Ermis, C
    Gupta-Malhotra, M
    Titus, JL
    CARDIOLOGY IN THE YOUNG, 2004, 14 (01) : 99 - 101
  • [8] PULMONARY VALVE CLOSURE IN TETRALOGY OF FALLOT
    HAUCK, AJ
    ZAVER, AG
    HUGENHOLTZ, PG
    NADAS, AS
    CIRCULATION, 1962, 26 (04) : 729 - &
  • [9] Tetralogy of Fallot with absent pulmonary valve
    Rego, Helena
    Jacinto, Teresa
    Araujo, Ana
    Teixeira, Ana
    Abecasis, Miguel
    Anjos, Rui
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2014, 33 (06) : 391 - 392
  • [10] ABSENCE OF PULMONARY VALVE IN TETRALOGY OF FALLOT
    RUTTENBERG, HD
    CAREY, LS
    ADAMS, P
    EDWARDS, JE
    AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1964, 91 (03): : 500 - &