Self-Gated Late Gadolinium Enhancement at 7T to Image Rats with Reperfused Acute Myocardial Infarction
被引:4
|作者:
Wang, Lei
[1
]
Chen, Yushu
[2
]
Zhang, Bing
[2
]
Chen, Wei
[2
]
Wang, Chunhua
[2
]
Song, Li
[1
]
Xu, Ziqian
[2
]
Zheng, Jie
[3
]
Gao, Fabao
[2
]
机构:
[1] Sichuan Univ, Mol Imaging Ctr, West China Hosp, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, Dept Radiol, West China Hosp, 37 Guoxue Alley, Chengdu 610041, Sichuan, Peoples R China
[3] Washington Univ, Mallinckrodt Inst Radiol, Sch Med, St Louis, MO 63110 USA
基金:
中国国家自然科学基金;
关键词:
Self-gated;
Myocardial infarction;
Flip angle;
MRI;
Late gadolinium enhancement;
Animal studies;
7T;
FLIP ANGLE OPTIMIZATION;
CARDIAC CINE MRI;
HEART-RATE;
CONTRAST;
FLASH;
MICE;
SEQUENCE;
SYSTEM;
MOUSE;
3T;
D O I:
10.3348/kjr.2018.19.2.247
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Objective: A failed electrocardiography (ECG)-trigger often leads to a long acquisition time (TA) and deterioration in image quality. The purpose of this study was to evaluate and optimize the technique of self-gated (SG) cardiovascular magnetic resonance (CMR) for cardiac late gadolinium enhancement (LGE) imaging of rats with myocardial infarction/reperfusion. Materials and Methods: Cardiovascular magnetic resonance images of 10 rats were obtained using SG-LGE or ECG with respiration double-gating (ECG-RESP-gating) method at 7T to compare differences in image interference and TA between the two methods. A variety of flip angles (FA: 10 degrees-80 degrees) and the number of repetitions (NR: 40, 80, 150, and 300) were investigated to determine optimal scan parameters of SG-LGE technique based on image quality score and contrast-to-noise ratio (CNR). Results: Self-gated late gadolinium enhancement allowed successful scan in 10 (100%) rats. However, only 4 (40%) rats were successfully scanned with the ECG-RESP-gating method. TAs with SG-LGE varied depending on NR used (TA: 41, 82, 154, and 307 seconds, corresponding to NR of 40, 80, 150, and 300, respectively). For the ECG-RESP-gating method, the average TA was 220 seconds. For SG-LGE images, CNR (42.5 +/- 5.5, 43.5 +/- 7.5, 54 +/- 9, 59.5 +/- 8.5, 56 +/- 13, 54 +/- 8, and 41 +/- 9) and image quality score (1.85 +/- 0.75, 2.20 +/- 0.83, 2.85 +/- 0.37, 3.85 +/- 0.52, 2.8 +/- 0.51, 2.45 +/- 0.76, and 1.95 +/- 0.60) were achieved with different FAs (10 degrees, 15 degrees, 20 degrees, 25 degrees, 30 degrees, 35 degrees, and 40 degrees, respectively). Optimal FAs of 20 degrees-30 degrees and NR of 80 were recommended. Conclusion: Self-gated technique can improve image quality of LGE without irregular ECG or respiration gating. Therefore, SG-LGE can be used an alternative method of ECG-RESP-gating.